Fire & Life Safety · Building Systems · Industrial Automation [email protected] +880 1347 561 256
Honeywell Process Measurement & Control

MBus

Falcon MJ Pulse/MBus

Falcon MJ reads compatible M100i and M120i multijet meters through an inductive pickup and provides pulse or wired M-bus output.

Falcon MJ reads compatible M100i and M120i multijet meters through an inductive pickup and provides pulse or wired M-bus output. Its pulse value can be changed using MBConf over M-bus, allowing the reporting increment to suit the collection system. The module supports the published OMS and interface standards for remote water-meter reading.

Features & Benefits

Meters
M100i and M120i
Pulse value
1–1,000 litres, programmable
Interface
Wired M-bus and pulse output
  • Inductive pickup aligns transmitted information with meter reading

Applications

  • Remote multijet water meter reading

Specifications

General Overview

Applications
Remote reading applications for residential water meters
Product Type
Combined Pulse and M‑Bus Communication Module

Operating Conditions

Storage Temperature
-20 to 70 deg C
Protection Class
IP68
Operating Temperature Range
-15 to +65 deg C

Interfaces

Standard Pulse Setting
100 litre per pulse; 100 ms pulse length

Sensing

Sensing Technology
Inductive sensing with 3 coils, non‑reactive

Power

Power Supply Mode
By M-Bus; battery supply in pulse mode or if M-Bus fails
Battery Lifetime
15 years typical (at 25 deg C ambient temperature)

Compatibility

Meter Compatibility
ELSTER M100i and M120i meters

Electrical

M-Bus Load
1 Load

Physical

Colour
Grey

Cabling

Cable Type
LiYY 5 x 0.14
Falcon MJ Pulse/MBus — manufacturer page values
ParameterPublished value / configuration
ApplicationsRemote reading applications for residential water meters
Product TypeCombined Pulse and M‑Bus Communication Module
Storage Temperature-20 to 70 deg C
Protection ClassIP68
Operating Temperature Range-15 to +65 deg C
Standard Pulse Setting100 litre per pulse; 100 ms pulse length
Sensing TechnologyInductive sensing with 3 coils, non‑reactive
Power Supply ModeBy M-Bus; battery supply in pulse mode or if M-Bus fails
Battery Lifetime15 years typical (at 25 deg C ambient temperature)
Meter CompatibilityELSTER M100i and M120i meters
M-Bus Load1 Load
ColourGrey
Cable TypeLiYY 5 x 0.14

Values retain manufacturer model qualifications. Review Honeywell specifications ↗

Resources

Filter documents by type

Resources linked from the manufacturer’s page. Confirm the document revision and applicable model before installation or ordering.

Honeywell resource listing ↗
Manufacturer sources

https://process.honeywell.com/us/en/products/utilities/water/digital-metering/mbus/falcon-mj-pulse-mbus

Last source check: 2026-11-02

Falcon MJ Pulse/MBus product image · Manufacturer ownership retained; republication licence not independently confirmed

ABID Automation LTD maintains this independent product reference. Honeywell owns its product names and trademarks. Current manufacturer documentation governs specification, availability and certification.

Your next project. A clear starting point.

Tell us about your facility and what you need to achieve.

CallSend enquiry