Turbine Meters
H4000 Bulk Water Meter
H4000 is a Woltmann-type meter for bulk cold potable water billing and network monitoring.
H4000 is a Woltmann-type meter for bulk cold potable water billing and network monitoring. It supports forward and reverse measurement, with reverse-flow performance qualifications dependent on size. Multiple pulse outputs add management information, while an inline strainer protects the rotor and a robust register supports readable operation over the meter's service life.
Models: H4000 Bulk Water Meter
Features & Benefits
- Sizes
- 40–300 mm
- Flow range
- 0.35–2,000 m³/h
- Maximum temperature
- 50 °C
- Maximum pressure
- 16 bar
- Broad measuring range and multiple outputs
Applications
- Commercial and industrial billing and water distribution monitoring
Detailed capabilities
H4000 Bulk Water Meter — purpose and arrangement
H4000 is a Woltmann-type meter for bulk cold potable water billing and network monitoring. It supports forward and reverse measurement, with reverse-flow performance qualifications dependent on size. Multiple pulse outputs add management information, while an inline strainer protects the rotor and a robust register supports readable operation over the meter's service life.
Forward and reverse measurement qualifications
H4000 supports forward or reverse metering, but the source’s class-B reverse-flow statement is limited to sizes up to150mm. Forward class-B installation permits horizontal, vertical or inclined orientations. The broader size range is40–300mm, so reverse-flow performance must not be extended automatically to the largest sizes.
Rotor protection and management information
An inline strainer shields the Woltmann rotor, while a protective shroud and copper register support readability. Multiple pulse outputs carry information to management systems. The source gives a0.35–2,000m³/h family flow range, fifty-degree maximum water temperature and sixteen-bar working pressure for bulk potable-water billing and network monitoring.
Dimensions & Sizes
- Sizes
- 40 to 300 mm
Operating Conditions
- Maximum Water Temperature
- 50 deg C
Pressure Ratings
- Maximum Working Pressure
- 16 bar
General Overview
- Installation Orientation
- Supports horizontal and vertical installation
- Measurement Type
- Velocity (Woltmann turbine)
- Applications
- Water supply, distribution, and industrial/bulk measurement
- Meter Types
- Bulk water meter (Woltmann type)
Flow
- Maximum Registration
- Up to 1 or 10 million m³ depending on size
Connection Options
- Connection Type
- Flanged
Flow & Performance
- Turndown Ratio
- 63 to 200
- Forward Flow
- Headloss at Max Flow:0.27 to 0.84 bar; Overload Flow (qs): 90 to 2000 m³/h depending on size; Permanent Flow (qp): 50 to 1500 m³/h; Starting Flow:~0.15 to 1.8 m³/h; Transitional Flow (qt):1 to 15 m³/h
Outputs
- Pulse Output
- PR7 inductive pulse transmitter supported
Interfaces
- Pulse Type
- Open collector pulse output
Physical
- Dimensions
- 151 to 461 mm Flange Diameter; 200 to 500 mm Length (ISO); 78 to 225 mm (basic), up to ~334 mm lid open Height
Measurement
- Flow Rate
- Q1 (Minimum):0.5 to 12.8 m³/h; Q2 (Transitional):0.81 to 20.48 m³/h; Q3 (Permanent):63 to 1600 m³/h; Q4 (Overload): 79 to 2000 m³/h
Safety & Compliance
- Approvals
- Measuring Instruments Directive 2014/32/EU (MID), Pressure Equipment Directive 97/23/EC (exempt)
| Parameter | Published value / configuration |
|---|---|
| Sizes | 40 to 300 mm |
| Maximum Water Temperature | 50 deg C |
| Maximum Working Pressure | 16 bar |
| Installation Orientation | Supports horizontal and vertical installation |
| Measurement Type | Velocity (Woltmann turbine) |
| Applications | Water supply, distribution, and industrial/bulk measurement |
| Meter Types | Bulk water meter (Woltmann type) |
| Maximum Registration | Up to 1 or 10 million m³ depending on size |
| Connection Type | Flanged |
| Turndown Ratio | 63 to 200 |
| Forward Flow | Headloss at Max Flow:0.27 to 0.84 bar; Overload Flow (qs): 90 to 2000 m³/h depending on size; Permanent Flow (qp): 50 to 1500 m³/h; Starting Flow:~0.15 to 1.8 m³/h; Transitional Flow (qt):1 to 15 m³/h |
| Pulse Output | PR7 inductive pulse transmitter supported |
| Pulse Type | Open collector pulse output |
| Dimensions | 151 to 461 mm Flange Diameter; 200 to 500 mm Length (ISO); 78 to 225 mm (basic), up to ~334 mm lid open Height |
| Flow Rate | Q1 (Minimum):0.5 to 12.8 m³/h; Q2 (Transitional):0.81 to 20.48 m³/h; Q3 (Permanent):63 to 1600 m³/h; Q4 (Overload): 79 to 2000 m³/h |
| Approvals | Measuring Instruments Directive 2014/32/EU (MID), Pressure Equipment Directive 97/23/EC (exempt) |
Values retain manufacturer model qualifications. Review Honeywell specifications ↗
Resources
Resources linked from the manufacturer’s page. Confirm the document revision and applicable model before installation or ordering.
Honeywell resource listing ↗Part Number
Published model / variant identifiers. A full ordering code requires the manufacturer configuration.
Published part numbers
10 parts
| Part Number | Description | Enquiry |
|---|---|---|
| 42541-00 | METER, 50MM H4000, CI | Request quotation |
| 42811-00 | STRAINER, 50MM H4010 | Request quotation |
| 42812-00 | STRAINER, 50MM H4010 | Request quotation |
| 42813-00 | STRAINER, 50MM H4010 | Request quotation |
| 42831-00 | STRAINER, 80MM H4010 | Request quotation |
| 42832-00 | STRAINER, 80MM H4010 | Request quotation |
| 42833-00 | STRAINER, 80MM H4010 | Request quotation |
| 42841-00 | STRAINER, 100MM H4010 | Request quotation |
| 42842-00 | STRAINER, 100MM H4010 | Request quotation |
| 42843-00 | STRAINER, 100MM H4010 | Request quotation |
Manufacturer sources
Last source check: 2026-11-02
H4000 product image · Manufacturer ownership retained; republication licence not independently confirmed
ABID Automation LTD maintains this independent product reference. Honeywell owns its product names and trademarks. Current manufacturer documentation governs specification, availability and certification.
Your next project. A clear starting point.
Tell us about your facility and what you need to achieve.