Turbine Meters
C4000 Combination Water Meter
C4000 combines a main Woltmann measurement chamber with a secondary volumetric meter for lower flows.
C4000 combines a main Woltmann measurement chamber with a secondary volumetric meter for lower flows. This arrangement covers installations with large demand variation and permits horizontal, vertical or inclined pipelines. The two measuring elements have distinct published performance classes, so the combination's broad flow capability should be assessed against the required installation and selected size.
Models: C4000 Combination Water Meter
Features & Benefits
- Sizes
- 50–100 mm
- Flow range
- 15 l/h–250 m³/h
- Elements
- Primary Woltmann and secondary V220 volumetric
- Extends both low- and high-flow measurement
Applications
- Bulk water applications with large flow variation
Detailed capabilities
C4000 Combination Water Meter — purpose and arrangement
C4000 combines a main Woltmann measurement chamber with a secondary volumetric meter for lower flows. This arrangement covers installations with large demand variation and permits horizontal, vertical or inclined pipelines. The two measuring elements have distinct published performance classes, so the combination's broad flow capability should be assessed against the required installation and selected size.
Different measuring elements across the flow range
At medium or high flow, the primary Woltmann chamber provides the source’s class-B measurement. At low flow, a secondary V220 volumetric meter provides class-C performance. This dual arrangement is designed for widely changing demand, with sizes fifty to one hundred millimeters and a stated family range from fifteen litres per hour to250m³/h.
Orientation and service
Horizontal, vertical and inclined pipelines are permitted without the stated accuracy loss. A compact inline body, register choices and accessible maintenance support installation. The two metrological classes remain tied to their respective measurement elements rather than being merged into one unqualified class for every flow condition.
Dimensions & Sizes
- Sizes
- 50, 65, 80, 100 mm
Flow & Performance
- Hydraulic Flow Rates
- Flow at 0.1 bar Headloss: 40 to 155 m³/h; Flow at 0.6 bar Headloss: 31 to 120 m³/h
- Turndown Ratio
- 1600 to 6300
Product Identification
- Configuration Type
- Main meter + by-pass (insert) meter
Mechanical & Physical
- Changeover Valve
- Closing Flow: 1.2 to 1.4 m³/h; Opening Flow: 1.8 to 2.4 m³/h
Outputs
- Pulse Output
- Supported via PR7 (main) and PR6 (bypass) pulsers
General Overview
- Applications
- Water supply, distribution, and discharge networks
- Meter Types
- Combination water meter (bulk flow + low flow measurement)
Interfaces
- Pulse Type
- Open collector pulse transmitter
Physical
- Dimensions
- 100 to 140 mm Width; 166 to 228 mm Diameter; 300 to 350 mm Length (ISO 4064), 270 to 360 mm Length(DIN 19625); 80 to 115 mm (basic), up to 321 mm (lid open) Height
Measurement
- Flow Rate
- Q1 (Minimum Flowrate): 0.016 m³/h; Q2 (Transitional Flowrate): 0.025 m³/h; Q3 (Permanent Flowrate): 25 to 100 m³/h; Q4 (Overload Flowrate): 31.25 to 125 m³/h depending on size
Safety & Compliance
- Approvals
- ISO 4064, DIN 19625, Pressure Equipment Directive 97/23/EC (exempt)
| Parameter | Published value / configuration |
|---|---|
| Sizes | 50, 65, 80, 100 mm |
| Hydraulic Flow Rates | Flow at 0.1 bar Headloss: 40 to 155 m³/h; Flow at 0.6 bar Headloss: 31 to 120 m³/h |
| Turndown Ratio | 1600 to 6300 |
| Configuration Type | Main meter + by-pass (insert) meter |
| Changeover Valve | Closing Flow: 1.2 to 1.4 m³/h; Opening Flow: 1.8 to 2.4 m³/h |
| Pulse Output | Supported via PR7 (main) and PR6 (bypass) pulsers |
| Applications | Water supply, distribution, and discharge networks |
| Meter Types | Combination water meter (bulk flow + low flow measurement) |
| Pulse Type | Open collector pulse transmitter |
| Dimensions | 100 to 140 mm Width; 166 to 228 mm Diameter; 300 to 350 mm Length (ISO 4064), 270 to 360 mm Length(DIN 19625); 80 to 115 mm (basic), up to 321 mm (lid open) Height |
| Flow Rate | Q1 (Minimum Flowrate): 0.016 m³/h; Q2 (Transitional Flowrate): 0.025 m³/h; Q3 (Permanent Flowrate): 25 to 100 m³/h; Q4 (Overload Flowrate): 31.25 to 125 m³/h depending on size |
| Approvals | ISO 4064, DIN 19625, Pressure Equipment Directive 97/23/EC (exempt) |
Values retain manufacturer model qualifications. Review Honeywell specifications ↗
Resources
Resources linked from the manufacturer’s page. Confirm the document revision and applicable model before installation or ordering.
Honeywell resource listing ↗Part Number
Published model / variant identifiers. A full ordering code requires the manufacturer configuration.
Published part numbers
10 parts
| Part Number | Description | Enquiry |
|---|---|---|
| DBA4107-00 | METER & STRAINER, 50X20MM C4000 | Request quotation |
| DBA4107-01 | METER & STRAINER, 50X20MM C4000 | Request quotation |
| DCA4107-00 | METER & STRAINER, 80X20MM C4000 | Request quotation |
| DCA4107-01 | METER & STRAINER, 80X20MM C4000 | Request quotation |
| DDA4107-00 | METER & STRAINER, 100X20MM C4000 | Request quotation |
| DDA4107-01 | METER & STRAINER, 100X20MM C4000 | Request quotation |
| DFA4107-00 | METER & STRAINER, 150X30MM C4200 | Request quotation |
| LAINLINE10016 | C 4000 DN100 PN16 30C length 360 FC | Request quotation |
| LAINLINE10016/XX | C 4000 DN100 PN16 30C length 360 FC | Request quotation |
| LAINLINE5016 | C 4000 DN 50 PN16 30C length 270 FC | Request quotation |
Manufacturer sources
Last source check: 2026-11-02
C4000 product image · Manufacturer ownership retained; republication licence not independently confirmed
ABID Automation LTD maintains this independent product reference. Honeywell owns its product names and trademarks. Current manufacturer documentation governs specification, availability and certification.
Your next project. A clear starting point.
Tell us about your facility and what you need to achieve.