Gas Risers
Rigid Risers
Rigid Risers provide permanent meter-set connections without cathodic protection.
Rigid Risers provide permanent meter-set connections without cathodic protection. The range includes a below-grade secondary fire seal and choices of Permasert or fusion outlets. Coated construction and standard or custom geometries support different installations, while the selected pipe size and below-ground connection define the actual riser assembly required for the service.
Features & Benefits
- Sizes
- ½–12 IPS
- Below-grade outlets
- Permasert or fusion
- Protection
- Secondary fire seal
- Anodeless connection avoids cathodic protection
Applications
- Gas meter-set service connections
General Overview
- Applications
- Transition from underground PE piping to above-ground meter connection
- Typical Uses
- Gas service lines for residential/commercial meter connections
- Product Type
- Service line riser (PE-to-steel transition riser)
Mechanical & Physical
- Transition Type
- Polyethylene-to-steel prefabricated riser
Operating Conditions
- Temperature Range
- Not explicitly specified in document
Dimensions & Sizes
- Steel Outlet Sizes
- 3/4 in, 1 in, 1-1/4 in, 1-1/2 in, 2 in, 3 in, 4 in NPT
- PE Inlet Sizes
- 1/2 in CTS, 1 in CTS, IPS sizes up to 4 in
Configuration
- SDR Compatibility
- SDR 10, SDR 11, SDR 11.5, etc.
Installation
- Installation Type
- Pre-fabricated riser, ready for installation
Construction
- Design Type
- Preassembled rigid riser unit
- Construction Materials
- PE Tubing (PE2406, PE3408, PE4710), Steel Outlet (threaded NPT)
- Coating Type
- Epoxy coated and/or galvanized steel casing
Flow & Performance
- Density Variants
- Medium (PE2406), High (PE3408, PE4710)
Safety & Compliance
- Approvals
- ASTM D-2513, ANSI B1.20, ANSI B31.8, US DOT Part 192, CSA B137.4
| Parameter | Published value / configuration |
|---|---|
| Applications | Transition from underground PE piping to above-ground meter connection |
| Typical Uses | Gas service lines for residential/commercial meter connections |
| Product Type | Service line riser (PE-to-steel transition riser) |
| Transition Type | Polyethylene-to-steel prefabricated riser |
| Temperature Range | Not explicitly specified in document |
| Steel Outlet Sizes | 3/4 in, 1 in, 1-1/4 in, 1-1/2 in, 2 in, 3 in, 4 in NPT |
| PE Inlet Sizes | 1/2 in CTS, 1 in CTS, IPS sizes up to 4 in |
| SDR Compatibility | SDR 10, SDR 11, SDR 11.5, etc. |
| Installation Type | Pre-fabricated riser, ready for installation |
| Design Type | Preassembled rigid riser unit |
| Construction Materials | PE Tubing (PE2406, PE3408, PE4710), Steel Outlet (threaded NPT) |
| Coating Type | Epoxy coated and/or galvanized steel casing |
| Density Variants | Medium (PE2406), High (PE3408, PE4710) |
| Approvals | ASTM D-2513, ANSI B1.20, ANSI B31.8, US DOT Part 192, CSA B137.4 |
Values retain manufacturer model qualifications. Review Honeywell specifications ↗
Part Number
Published part numbers
10 parts
| Part Number | Description | Enquiry |
|---|---|---|
| 09092120 | ANGLE IRON W/HOLE 1x1x1/8 12LG GRAY | Request quotation |
| 09180GN | SLIP SEAL,1 1/4IPSX1CTS | Request quotation |
| 09181GN | SLIP SEAL,3/4IPSX1/2CTS | Request quotation |
| 09203GN | SVSA,1/2X1/2CTS-090X3/4* | Request quotation |
| 09205020GN | PROT SLV,PE/UV 1 3/8IDX1/32X12 | Request quotation |
| 09234GN | SVSA 1X1IPS SDR11X1 1/2* | Request quotation |
| 09261GN | GAS LNR,PE 1.025X.020X49 | Request quotation |
| 09263GN | BRG SLV,3IPS X24 SDR17 HDPE | Request quotation |
| 09265GN | BRG SLV,PE 1.760X100X18 | Request quotation |
| 09286GN | BRG SLV PE 2.420 X .100 X 24 | Request quotation |
Manufacturer sources
Last source check: 2026-11-02