Fire & Life Safety · Building Systems · Industrial Automation [email protected] +880 1347 561 256
Honeywell Process Measurement & Control

Safety Systems

Guardian Surge Detection System (SDS)

Guardian SDS combines compressor surge detection with the overspeed functions of Guardian ODS in one independent safety unit.

Guardian SDS combines compressor surge detection with the overspeed functions of Guardian ODS in one independent safety unit. Configurable limits cover speed, acceleration, flow and differential pressure, while settings require local access. The manufacturer publishes SIL3 capability and integration with CCC control systems, supporting a separate protective layer against damaging compressor operating conditions.

Features & Benefits

Protection
Surge, overspeed and acceleration
Architecture
Independent safety device
  • Combines surge and overspeed protection separately from process control

Applications

  • Critical compressor safety monitoring

Detailed capabilities

Product and configuration

Guardian SDS combines compressor surge detection with the overspeed functions of Guardian ODS in one independent safety unit. Configurable limits cover speed, acceleration, flow and differential pressure, while settings require local access. The manufacturer publishes SIL3 capability and integration with CCC control systems, supporting a separate protective layer against damaging compressor operating conditions.

  • Protection: Surge, overspeed and acceleration
  • Architecture: Independent safety device

Manufacturer reference ↗

Operation and integration

Guardian SDS adds surge-detection algorithms to the ODS overspeed functionality in one physically separate safety unit. Speed, acceleration, flow and differential-pressure limits can be configured for the machine. Local-only settings retain the separation from routine control changes, while the source describes SIL3 capability and the relevant API standards context.

Manufacturer reference ↗

Application and selection

Combining the two protective duties can reduce separate equipment while maintaining the source's safety/control independence. The full shutdown path, sensors and certified configuration remain part of the installed safety system. SDS should not be reduced to a software option in the main compressor controller.

Manufacturer reference ↗

Case studies & further resources

Resources

Filter documents by type
NameLast checkedType

Resources linked from the manufacturer’s page. Confirm the document revision and applicable model before installation or ordering.

Honeywell resource listing ↗
Manufacturer sources

https://process.honeywell.com/us/en/products/turbomachinery-automation-systems/ccc-pro-built/safety-systems/guardian-surge-detection-system-sds

Last source check: 2026-11-02

Guardian Surge Detection System (SDS) Product Image · Manufacturer ownership retained; republication licence not independently confirmed

ABID Automation LTD maintains this independent product reference. Honeywell owns its product names and trademarks. Current manufacturer documentation governs specification, availability and certification.

Your next project. A clear starting point.

Tell us about your facility and what you need to achieve.

CallSend enquiry