Safety Systems
Guardian Overspeed Detection System (ODS)
Guardian ODS monitors rotating equipment for overspeed and excessive acceleration using a safety system physically separated from the normal controller.
Guardian ODS monitors rotating equipment for overspeed and excessive acceleration using a safety system physically separated from the normal controller. Settings require direct access to the unit, limiting remote changes. The system integrates with CCC controls and is published as SIL3-capable, providing an independent protection layer for critical turbines and other rotating machinery.
Features & Benefits
- Protection
- Overspeed and acceleration
- Architecture
- Physically separate from normal control
- Adds independent rotating-equipment protection
Applications
- Compressors and turbines
Detailed capabilities
Product and configuration
Guardian ODS monitors rotating equipment for overspeed and excessive acceleration using a safety system physically separated from the normal controller. Settings require direct access to the unit, limiting remote changes. The system integrates with CCC controls and is published as SIL3-capable, providing an independent protection layer for critical turbines and other rotating machinery.
- Protection: Overspeed and acceleration
- Architecture: Physically separate from normal control
Operation and integration
Guardian ODS monitors speed and acceleration independently of the normal process controller. Settings can be changed only by direct access to the unit, supporting separation of routine control and protection. The page publishes SIL3 capability and references API670, API611 and API612 for the configured overspeed arrangement, with integration to CCC systems for the needed operating visibility.
Application and selection
This device serves turbine and compressor protection against dangerous rotational conditions. Its separate hardware helps avoid a shared controller failure path, while the applicable certificate, sensors, voting and trip implementation define the complete safety function. The product page does not make every connected rotating-machine installation automatically compliant.
Technical Specifications
- Protection Functions
- Overspeed shutdown; optional over-acceleration protection
- Speed Inputs
- 1 per module, 3 total
- MPU Input
- 100–32000 Hz at 1–35 Vrms
- Proximity Probe Input
- 0.5–25000 Hz at 24 VDC
- Gear-Tooth Range
- 1–320 teeth
- Redundant Power Sources
- 2 redundant supplies; high-voltage option 88–264 VAC at 47–63 Hz or 90–150 VDC, 90 W; low-voltage option 18–32 VDC, 100 W
- Discrete Inputs
- 3 per module, 9 total: alarm/trip reset, start and speed-fail override commands
- Shutdown Relay Outputs
- Voted-relay models: 2 shutdown outputs with 2-out-of-3 voting; 8 A at 220 VAC or 8 A at 24 VDC
- Alarm Relay Outputs
- Voted-relay models: 1 per module, 3 total; 2 A at 24 VDC
- Analog Speed Readout
- 4–20 mA; 1 per module, 3 total
- Communication Ports
- 1 per module, 3 total; RS-232, RS-422 and RS-485 Modbus
- Operating Temperature
- −20 to +60 °C (−4 to +140 °F)
- Location Protection Rating
- IP56-rated locations
- Approximate Dimensions Including Faceplate
- 330 × 445 × 159 mm (13 × 17.5 × 6.25 in)
- Event History
- Last 50 trip/alarm events and last 20 overspeed events, with times; non-volatile memory
- Published North American Compliance
- CSA Class I, Division 2, Groups A/B/C/D, T4 at 60 °C ambient, for Canada and USA (manufacturer DS8405 statement)
- Published European Compliance
- EMC 2014/30/EU; ATEX 2014/34/EU Zone 2, Category 3, Group II G, Ex nA II T4 (manufacturer DS8405 statement)
- Published Functional-Safety Compliance
- TÜV SIL-3 per IEC 61508 Parts 1–7, as stated in manufacturer DS8405
- Published Machinery Standards
- API670, API612 and API611, as stated in manufacturer DS8405
| Parameter | Published value / configuration |
|---|---|
| Protection Functions | Overspeed shutdown; optional over-acceleration protection |
| Speed Inputs | 1 per module, 3 total |
| MPU Input | 100–32000 Hz at 1–35 Vrms |
| Proximity Probe Input | 0.5–25000 Hz at 24 VDC |
| Gear-Tooth Range | 1–320 teeth |
| Redundant Power Sources | 2 redundant supplies; high-voltage option 88–264 VAC at 47–63 Hz or 90–150 VDC, 90 W; low-voltage option 18–32 VDC, 100 W |
| Discrete Inputs | 3 per module, 9 total: alarm/trip reset, start and speed-fail override commands |
| Shutdown Relay Outputs | Voted-relay models: 2 shutdown outputs with 2-out-of-3 voting; 8 A at 220 VAC or 8 A at 24 VDC |
| Alarm Relay Outputs | Voted-relay models: 1 per module, 3 total; 2 A at 24 VDC |
| Analog Speed Readout | 4–20 mA; 1 per module, 3 total |
| Communication Ports | 1 per module, 3 total; RS-232, RS-422 and RS-485 Modbus |
| Operating Temperature | −20 to +60 °C (−4 to +140 °F) |
| Location Protection Rating | IP56-rated locations |
| Approximate Dimensions Including Faceplate | 330 × 445 × 159 mm (13 × 17.5 × 6.25 in) |
| Event History | Last 50 trip/alarm events and last 20 overspeed events, with times; non-volatile memory |
| Published North American Compliance | CSA Class I, Division 2, Groups A/B/C/D, T4 at 60 °C ambient, for Canada and USA (manufacturer DS8405 statement) |
| Published European Compliance | EMC 2014/30/EU; ATEX 2014/34/EU Zone 2, Category 3, Group II G, Ex nA II T4 (manufacturer DS8405 statement) |
| Published Functional-Safety Compliance | TÜV SIL-3 per IEC 61508 Parts 1–7, as stated in manufacturer DS8405 |
| Published Machinery Standards | API670, API612 and API611, as stated in manufacturer DS8405 |
Values retain manufacturer model qualifications. Review Honeywell specifications ↗
Resources
Resources linked from the manufacturer’s page. Confirm the document revision and applicable model before installation or ordering.
Honeywell resource listing ↗Manufacturer sources
Last source check: 2026-11-02
Guardian Overspeed Detection System (ODS) Product Image · Manufacturer ownership retained; republication licence not independently confirmed
ABID Automation LTD maintains this independent product reference. Honeywell owns its product names and trademarks. Current manufacturer documentation governs specification, availability and certification.
Your next project. A clear starting point.
Tell us about your facility and what you need to achieve.