Honeywell Process Measurement & Control

valVario Valves

VAA Solenoid valve for air

VAA solenoid valves stage cold combustion air and close when deenergized.

VAA solenoid valves stage cold combustion air and close when deenergized. A pilot lamp and flow adjustment are included, with opening/closing-speed choices and optional signal/position indication or adjustable bypass. Threaded or flanged sizes, supply voltages and connections allow the valve arrangement to match the burner-control circuit.

Features & Benefits

Gas Type
Clean, dry air only|No condensate allowed
Maximum Installation Height
2000 m AMSL
Ambient Temperature Range
-20 to +60 deg C (-4 to +140 deg F)
Position Switch Options
VAA..S (visual), VAA..G (24VDC)
Position Switch Rating
S: 12-250VAC; G: 12-30VDC
Electrical Connections
M20 X 1.5 Cable Gland or En 175301-803 Plug
Flow Adjustment Range
20 to 100% adjustable with visual indicator
Maintenance Interval
Annual functional check recommended
Inlet Pressure Range
500 mbar (7.25 psig)
Switching Frequency
N: 30/min, L: 2/min, R: 6/min
Opening Variants
VAA../N (<1 s), VAA../L (up to 10 s), VAA../R (4 s)
Enclosure Rating
IP65
Connection Type
Rp Thread, NPT Thread, ISO Flange
Voltage Rating
230/200/120/100 VAC; 24 VDC
LED Indicator
Blue LED for energized/open
Bypass Option
Variable bypass (retrofit) Order No. 74926325
Body Material
Aluminium housing, EPDM seals
Closing Time
VAA../N and VAA../L: <1 seconds|VAA../R: 4 seconds
Valve Type
Normally closed; opens when powered
Duty Cycle
100%
Approvals
CE, EN 161, UL429, CSA C22.2 No.139-19
Size
1 to 3
DN
15 to 65
Mains voltage
24 V=, 120 V~ or 230 V~
  • Optional indication and bypass arrangements support staged-air control.

Applications

  • Staged cold-air burner control

Specifications

Fuel, Gas & Media Specifications

Gas Type
Clean, dry air only; No condensate allowed

Dimensions & Weight

Maximum Installation Height
2000 m AMSL

Environmental Conditions

Ambient Temperature Range
-20 to +60 deg C (-4 to +140 deg F)
Enclosure Rating
IP65

Actuation, Valve & Motion Control Specifications

Position Switch Options
VAA..S (visual), VAA..G (24VDC)
Position Switch Rating
S: 12-250VAC; G: 12-30VDC
Opening Variants
VAA../N (<1 s), VAA../L (up to 10 s), VAA../R (4 s)
Closing Time
VAA../N and VAA../L: <1 seconds; VAA../R: 4 seconds
Valve Type
Normally closed; opens when powered

Connections & Interfaces

Electrical Connections
M20 X 1.5 Cable Gland or En 175301-803 Plug
Connection Type
Rp Thread, NPT Thread, ISO Flange

Processing & Performance Metrics

Flow Adjustment Range
20 to 100% adjustable with visual indicator
Duty Cycle
100%

Electrical Specifications

Maintenance Interval
Annual functional check recommended
Switching Frequency
N: 30/min, L: 2/min, R: 6/min
Voltage Rating
230/200/120/100 VAC; 24 VDC

Pressure Specifications

Inlet Pressure Range
500 mbar (7.25 psig)

Alarms, Status & Diagnostics

LED Indicator
Blue LED for energized/open

Mechanical Design & Adjustment Characteristics

Bypass Option
Variable bypass (retrofit) Order No. 74926325

Material Specifications

Body Material
Aluminium housing, EPDM seals

Applications & Compatibility

Applications
Staged control of industrial burners in cold-air mode

Standards & Certifications

Approvals
CE, EN 161, UL429, CSA C22.2 No.139-19

Technical Specifications

Size
1 to 3
DN
15 to 65
Mains voltage
24 V=, 120 V~ or 230 V~
VAA Solenoid valve for air — manufacturer page values
ParameterPublished value / configuration
Gas TypeClean, dry air only; No condensate allowed
Maximum Installation Height2000 m AMSL
Ambient Temperature Range-20 to +60 deg C (-4 to +140 deg F)
Enclosure RatingIP65
Position Switch OptionsVAA..S (visual), VAA..G (24VDC)
Position Switch RatingS: 12-250VAC; G: 12-30VDC
Opening VariantsVAA../N (<1 s), VAA../L (up to 10 s), VAA../R (4 s)
Closing TimeVAA../N and VAA../L: <1 seconds; VAA../R: 4 seconds
Valve TypeNormally closed; opens when powered
Electrical ConnectionsM20 X 1.5 Cable Gland or En 175301-803 Plug
Connection TypeRp Thread, NPT Thread, ISO Flange
Flow Adjustment Range20 to 100% adjustable with visual indicator
Duty Cycle100%
Maintenance IntervalAnnual functional check recommended
Switching FrequencyN: 30/min, L: 2/min, R: 6/min
Voltage Rating230/200/120/100 VAC; 24 VDC
Inlet Pressure Range500 mbar (7.25 psig)
LED IndicatorBlue LED for energized/open
Bypass OptionVariable bypass (retrofit) Order No. 74926325
Body MaterialAluminium housing, EPDM seals
ApplicationsStaged control of industrial burners in cold-air mode
ApprovalsCE, EN 161, UL429, CSA C22.2 No.139-19
Size1 to 3
DN15 to 65
Mains voltage24 V=, 120 V~ or 230 V~

Values retain manufacturer model qualifications. Review Honeywell specifications ↗

Part Number

Published part numbers

10 parts

Part NumberDescriptionEnquiry
KS88035685VAA240R/NWRequest quotation
KS88035696VAA125R/RWRequest quotation
KS88035699VAA240R/RWRequest quotation
KS88035727VAA240R/NQRequest quotation
KS88035744VAA350R/RQRequest quotation
KS88035783VAA3T50N/RQRequest quotation
KS88035824VAA125R/NWRequest quotation
KS88035834VAA240R/LWRequest quotation
KS88035838VAA240R/NWRequest quotation
KS88035990Vlv, VAA3T-/RQ 120 V AC - 50/60 HzRequest quotation
Manufacturer sources

https://process.honeywell.com/us/en/products/thermal-solutions/fuel-and-air-delivery/valvario-valves/vaa-solenoid-valve-for-air

Last source check: 2026-11-02

Solenoid valve for air VAA · Manufacturer ownership retained; republication licence not independently confirmed

ABID Automation LTD maintains this independent product reference. Honeywell owns its product names and trademarks. Current manufacturer documentation governs specification, availability and certification.

Your next project. A clear starting point.

Tell us about your facility and what you need to achieve.

CallSend enquiry