Control Valves
V47/V87/VR/VMU Series
V47/V87 servo valves and VMU venturi mixers form combinations for modulating premix burners and boilers.
V47/V87 servo valves and VMU venturi mixers form combinations for modulating premix burners and boilers. The gas valves and mixing units have different temperature limits and material details. Sensing-tube length depends on whether a manual shutoff valve is fitted, and mounting choices support connection to the specified DC fan arrangement.
Features & Benefits
- Ambient Temperature Range
- -15 to +60 deg C (5 to +140 deg F)
- Voltage Rating
- 24 VAC or 120 VAC, 50/60 Hz (model‑dependent)
- Valve Sizes
- 1/2 in, 3/4 in, 1 in, 1-1/4 in
- Strainer Material
- AISI 303 Steel, 0.34 mm Mesh
- Storage Temperature Range
- -20 to +40 deg C (-4 to +104 deg F)
- Seal Material
- Hydrocarbon-resistant NBR and Viton rubber
- Product Type
- 1:1 gas/air servo‑regulated combination gas valve with optional venturi mixing unit (VMU)
- Opening Time
- Dead time max. 1 seconds; first valve <0.5 second; second valve within 5 second
- Minimum Load
- 14 to 17% of reference load
- Leakage Rating
- Max. 2.5 in³/h (40 cm³/h) for DN ≤ 25; 3 in³/h (50 cm³/h) for DN 32
- Installation Orientation
- Upright or horizontal; ±90 deg tolerance
- Fuel Type
- Gaseous fuels (e.g., natural gas); air for premixing
- Enclosure Rating
- NEMA 1 (IP40)
- Electrical Connections
- DIN 43650 plug with 914 mm lead wires
- Body Material
- Die-Cast Aluminum Alloy
- Approvals
- UL429 - Electrically operated valves, ANSI Z21.21 and CSA 6.5, EN 161 (strainers), EN 13611 (pipe stress), Coil Insulation Class F, Meets EN 161 requirements
- Materials
- Body: Aluminum alloy, die-cast Frequency: 50 Hz; 60 Hz Ambient Temperature Range: 5°F to 140°F (-15°C to +60°C)
- Approvals, CSA
- File: Certificate No: 158158-1227192
- Approvals, Others
- Gas Appliance Directive: 90.396/EEC, PIN: 0063AT1198, Low Voltage Directive: 73/23/EEC, Electro Magnetic Compatibility Directive: 89/336/EEC
- Maximum Safe Operating Pressure (psi)
- 0.5 psi (CSA approved), 1.45 psi for 120V)
- Maximum Operating Pressure (mbar)
- 35 mbar (CSA approved)
- Pipe Connection
- Four M5 screws and a rubber O-ring are provided with the venturi to assemble it to the V4730C/V8730C gas valve
- Flexible valve/venturi/fan mounting supports premix appliance layouts.
Applications
- Modulating premix burners and boilers
Detailed capabilities
Servo valve and venturi mixer form one premix arrangement
The V4730C/V8730C valve and VMU venturi are designed with a specified DC fan for modulating premix appliances. The valve responds to the venturi pressure signal, so the source's minimum load and differential pressure describe that combined system. The valve body and VMU have different material and temperature specifications, which should not be collapsed into one assembly rating without preserving the component context.
Sensing tubes, mounting and regional pressure limits
The venturi attaches to the valve through screws and an O-ring, while a stainless sensing tube connects the venturi inlet to the regulator. KTTBA002 is the longer tube used with a manual shutoff; KTTBA001 serves the arrangement without it. Flexible valve/venturi/fan mounting is described. CSA pressure limits and the separately stated 120 V pressure figure carry different approval context and must remain qualified.
Features and benefits
- Flexible valve/venturi/fan mounting supports premix appliance layouts.
Published application context
- Modulating premix burners and boilers
Technical facts in the product overview
- Materials: Body: Aluminum alloy, die-cast Frequency: 50 Hz; 60 Hz Ambient Temperature Range: 5°F to 140°F (-15°C to +60°C)
- Approvals, CSA: File: Certificate No: 158158-1227192
- Approvals, Others: Gas Appliance Directive: 90.396/EEC, PIN: 0063AT1198, Low Voltage Directive: 73/23/EEC, Electro Magnetic Compatibility Directive: 89/336/EEC
- Maximum Safe Operating Pressure (psi): 0.5 psi (CSA approved), 1.45 psi for 120V)
- Maximum Operating Pressure (mbar): 35 mbar (CSA approved)
- Pipe Connection: Four M5 screws and a rubber O-ring are provided with the venturi to assemble it to the V4730C/V8730C gas valve
Environmental Conditions
- Ambient Temperature Range
- -15 to +60 deg C (5 to +140 deg F)
- Enclosure Rating
- NEMA 1 (IP40)
Electrical Specifications
- Voltage Rating
- 24 VAC or 120 VAC, 50/60 Hz (model‑dependent)
Dimensions & Size Specifications
- Valve Sizes
- 1/2 in, 3/4 in, 1 in, 1-1/4 in
Applications & Compatibility
- Typical Applications
- Gas burners, gas boilers, rooftop units, fresh air units, and industrial process applications
Material Specifications
- Strainer Material
- AISI 303 Steel, 0.34 mm Mesh
- Seal Material
- Hydrocarbon-resistant NBR and Viton rubber
- Body Material
- Die-Cast Aluminum Alloy
Storage/Transport Temperatures
- Storage Temperature Range
- -20 to +40 deg C (-4 to +104 deg F)
Overview
- Product Type
- 1:1 gas/air servo‑regulated combination gas valve with optional venturi mixing unit (VMU)
Actuation, Valve & Motion Control Specifications
- Opening Time
- Dead time max. 1 seconds; first valve <0.5 second; second valve within 5 second
Operating Limits & Resistance
- Minimum Load
- 14 to 17% of reference load
Safety, Protection & Reliability
- Leakage Rating
- Max. 2.5 in³/h (40 cm³/h) for DN ≤ 25; 3 in³/h (50 cm³/h) for DN 32
Installation & Mounting Specifications
- Installation Orientation
- Upright or horizontal; ±90 deg tolerance
Fuel, Gas & Media Specifications
- Fuel Type
- Gaseous fuels (e.g., natural gas); air for premixing
Connections & Interfaces
- Electrical Connections
- DIN 43650 plug with 914 mm lead wires
Standards & Certifications
- Approvals
- UL429 - Electrically operated valves, ANSI Z21.21 and CSA 6.5, EN 161 (strainers), EN 13611 (pipe stress), Coil Insulation Class F, Meets EN 161 requirements
Technical Specifications
- Materials
- Body: Aluminum alloy, die-cast Frequency: 50 Hz; 60 Hz Ambient Temperature Range: 5°F to 140°F (-15°C to +60°C)
- Approvals, CSA
- File: Certificate No: 158158-1227192
- Approvals, Others
- Gas Appliance Directive: 90.396/EEC, PIN: 0063AT1198, Low Voltage Directive: 73/23/EEC, Electro Magnetic Compatibility Directive: 89/336/EEC
- Maximum Safe Operating Pressure (psi)
- 0.5 psi (CSA approved), 1.45 psi for 120V)
- Maximum Operating Pressure (mbar)
- 35 mbar (CSA approved)
- Pipe Connection
- Four M5 screws and a rubber O-ring are provided with the venturi to assemble it to the V4730C/V8730C gas valve
| Parameter | Published value / configuration |
|---|---|
| Ambient Temperature Range | -15 to +60 deg C (5 to +140 deg F) |
| Enclosure Rating | NEMA 1 (IP40) |
| Voltage Rating | 24 VAC or 120 VAC, 50/60 Hz (model‑dependent) |
| Valve Sizes | 1/2 in, 3/4 in, 1 in, 1-1/4 in |
| Typical Applications | Gas burners, gas boilers, rooftop units, fresh air units, and industrial process applications |
| Strainer Material | AISI 303 Steel, 0.34 mm Mesh |
| Seal Material | Hydrocarbon-resistant NBR and Viton rubber |
| Body Material | Die-Cast Aluminum Alloy |
| Storage Temperature Range | -20 to +40 deg C (-4 to +104 deg F) |
| Product Type | 1:1 gas/air servo‑regulated combination gas valve with optional venturi mixing unit (VMU) |
| Opening Time | Dead time max. 1 seconds; first valve <0.5 second; second valve within 5 second |
| Minimum Load | 14 to 17% of reference load |
| Leakage Rating | Max. 2.5 in³/h (40 cm³/h) for DN ≤ 25; 3 in³/h (50 cm³/h) for DN 32 |
| Installation Orientation | Upright or horizontal; ±90 deg tolerance |
| Fuel Type | Gaseous fuels (e.g., natural gas); air for premixing |
| Electrical Connections | DIN 43650 plug with 914 mm lead wires |
| Approvals | UL429 - Electrically operated valves, ANSI Z21.21 and CSA 6.5, EN 161 (strainers), EN 13611 (pipe stress), Coil Insulation Class F, Meets EN 161 requirements |
| Materials | Body: Aluminum alloy, die-cast Frequency: 50 Hz; 60 Hz Ambient Temperature Range: 5°F to 140°F (-15°C to +60°C) |
| Approvals, CSA | File: Certificate No: 158158-1227192 |
| Approvals, Others | Gas Appliance Directive: 90.396/EEC, PIN: 0063AT1198, Low Voltage Directive: 73/23/EEC, Electro Magnetic Compatibility Directive: 89/336/EEC |
| Maximum Safe Operating Pressure (psi) | 0.5 psi (CSA approved), 1.45 psi for 120V) |
| Maximum Operating Pressure (mbar) | 35 mbar (CSA approved) |
| Pipe Connection | Four M5 screws and a rubber O-ring are provided with the venturi to assemble it to the V4730C/V8730C gas valve |
Values retain manufacturer model qualifications. Review Honeywell specifications ↗
Part Number
Published part numbers
10 parts
| Part Number | Description | Enquiry |
|---|---|---|
| 50002653-001/U | VALVE KIT ( 1500000) | Request quotation |
| 50002653-002/U | VALVE KIT (#1500001) | Request quotation |
| C60VRT40040 | PRESSURE SWITCH 5-40MBAR USA | Request quotation |
| KTSERVF1 | KIT PER SERVO COMBI CON VENTURI | Request quotation |
| KTSERVF1B | KIT PER SERVO COMBI CON VENTURI | Request quotation |
| KTVIT001 | KIT VITI PER VENTURI ( 150 /300 KW ) | Request quotation |
| VMU150A1003 | MANIFOLD - 150KW | Request quotation |
| VMU150A1011 | VENTURI 150 KW FOR V47/8730C | Request quotation |
| VMU150A1045 | VENTURI 150KW+KTSERVF1+KTVIT001 SPECIAL | Request quotation |
| VMU150A1052 | VENTURI 150KW WITH INSERT | Request quotation |