Glass & Oxygen Burners
PrimeFire 400
PrimeFire 400 uses a flat oxy-fuel flame and a rear precombustor that cracks part of the fuel stream.
PrimeFire 400 uses a flat oxy-fuel flame and a rear precombustor that cracks part of the fuel stream. The resulting carbon particles raise luminosity and radiant transfer toward the glass. The family lists natural-gas and oil firing, four maximum-capacity groups and 4:1 turndown, with reduced peak temperature supporting lower NOx.
Features & Benefits
- Turndown Ratio
- 4:1
- Sizes
- 2, 4, 10, 20 MMBtu/hr
- Nozzle Material
- Oxygen - 304 stainless steel (2MM-10MM), 446 stainless steel (20MM), Gas - Inconel 600 (2MM-10MM), 446 stainless steel (20MM)
- NOx Emissions
- Up to 18% reduction in thermal NOx due to lower overall flame temperature
- Maintenance Interval
- Shut off gas for 15-20 seconds with oxygen flowing to burn off carbon deposits
- Heat Transfer Mechanism
- Pre‑combustor creates free carbon particles to increase luminosity and radiant heat transfer
- Fuel Type
- Natural Gas or Fuel Oil
- Flame Velocity
- 15.5 to 48.8 m/s
- Flame Length
- 0.8 to 2.44 m
- Flame Geometry
- Flat flame
- Cooling
- Non‑water cooled
- Capacity Range
- 2,000,000 to 20,000,000 Btu/hr
- Burner Type
- Oxy-fuel flat flame burner with gas pre-heating (oxygen injected into gas stream prior to main combustion)
- The precombustor increases luminosity and transfer toward the glass.
Applications
- Glass melting
Detailed capabilities
Precombustion and radiant transfer
PrimeFire 400 mixes part of the oxygen with fuel in a rear precombustor. Fuel cracking creates free carbon particles that increase luminosity and radiation to the glass, while flat-flame geometry distributes the heat. Natural-gas and oil arrangements are listed with four capacity groups. The stated turndown and low-NOx advantages apply to this design and should not be transferred to other PrimeFire geometries.
Features and benefits
- The precombustor increases luminosity and transfer toward the glass.
Published application context
- Glass melting
Applications & Compatibility
- Applications
- Enhanced flame coverage and uniform heat distribution; Glass melting furnaces
Performance, Flow & Capacity
- Turndown Ratio
- 4:1
- Heat Transfer Mechanism
- Pre‑combustor creates free carbon particles to increase luminosity and radiant heat transfer
Dimensions & Size Specifications
- Sizes
- 2, 4, 10, 20 MMBtu/hr
Material Specifications
- Nozzle Material
- Oxygen - 304 stainless steel (2MM-10MM), 446 stainless steel (20MM), Gas - Inconel 600 (2MM-10MM), 446 stainless steel (20MM)
Processing & Performance Metrics
- NOx Emissions
- Up to 18% reduction in thermal NOx due to lower overall flame temperature
- Capacity Range
- 2,000,000 to 20,000,000 Btu/hr
Electrical Specifications
- Maintenance Interval
- Shut off gas for 15-20 seconds with oxygen flowing to burn off carbon deposits
Fuel, Gas & Media Specifications
- Fuel Type
- Natural Gas or Fuel Oil
Ignition, Flame & Supervision Specifications
- Flame Velocity
- 15.5 to 48.8 m/s
- Flame Geometry
- Flat flame
Burner/Flame‑Related Lengths
- Flame Length
- 0.8 to 2.44 m
Thermal, Flow & Process Characteristics
- Cooling
- Non‑water cooled
Overview
- Burner Type
- Oxy-fuel flat flame burner with gas pre-heating (oxygen injected into gas stream prior to main combustion)
| Parameter | Published value / configuration |
|---|---|
| Applications | Enhanced flame coverage and uniform heat distribution; Glass melting furnaces |
| Turndown Ratio | 4:1 |
| Heat Transfer Mechanism | Pre‑combustor creates free carbon particles to increase luminosity and radiant heat transfer |
| Sizes | 2, 4, 10, 20 MMBtu/hr |
| Nozzle Material | Oxygen - 304 stainless steel (2MM-10MM), 446 stainless steel (20MM), Gas - Inconel 600 (2MM-10MM), 446 stainless steel (20MM) |
| NOx Emissions | Up to 18% reduction in thermal NOx due to lower overall flame temperature |
| Capacity Range | 2,000,000 to 20,000,000 Btu/hr |
| Maintenance Interval | Shut off gas for 15-20 seconds with oxygen flowing to burn off carbon deposits |
| Fuel Type | Natural Gas or Fuel Oil |
| Flame Velocity | 15.5 to 48.8 m/s |
| Flame Geometry | Flat flame |
| Flame Length | 0.8 to 2.44 m |
| Cooling | Non‑water cooled |
| Burner Type | Oxy-fuel flat flame burner with gas pre-heating (oxygen injected into gas stream prior to main combustion) |
Values retain manufacturer model qualifications. Review Honeywell specifications ↗
Part Number
Published part numbers
10 parts
| Part Number | Description | Enquiry |
|---|---|---|
| 020778-1 | CMBSTR,RFRCT,PF400,20MM BTU/HR,330MM X 5 | Request quotation |
| 020778-2 | CMBSTR,RFRCT,PF400,20MM BTU/HR,330MM X 5 | Request quotation |
| 020778-4 | CMBSTR,RFRCT,PF400,20MM BTU/HR,330MM X 5 | Request quotation |
| 020778-5 | CMBSTR,RFRCT,PF400,20MM BTU/HR,330MM X 5 | Request quotation |
| 020787-1 | CMBSTR,RFRCT,PF400,10MM BTU/HR,330MM X 4 | Request quotation |
| 020787-2 | CMBSTR,RFRCT,PF400,10MM BTU/HR,330MM X 4 | Request quotation |
| 020787-3 | CMBSTR,RFRCT,PF400,10MM BTU/HR,330MM X 4 | Request quotation |
| 020787-4 | CMBSTR,RFRCT,PF400,10MM BTU/HR,330MM X 4 | Request quotation |
| 020787-5 | CMBSTR,RFRCT,PF400,10MM BTU/HR,330MM X 4 | Request quotation |
| 020797 | GSKT,FLG,MTG,CMBSTR,PRMFR,PF400,10 MM BT | Request quotation |
Manufacturer sources
Last source check: 2026-11-02
PrimeFire 400 Product Image · Manufacturer ownership retained; republication licence not independently confirmed
ABID Automation LTD maintains this independent product reference. Honeywell owns its product names and trademarks. Current manufacturer documentation governs specification, availability and certification.