Fire & Life Safety · Building Systems · Industrial Automation [email protected] +880 1347 561 256
Honeywell Process Measurement & Control

Glass & Oxygen Burners

BrightFire 200

BrightFire 200 allows both gas-flow and discharge-area adjustment to shape heat delivery in regenerative glass furnaces.

BrightFire 200 allows both gas-flow and discharge-area adjustment to shape heat delivery in regenerative glass furnaces. The air-fuel burner targets low NOx while improving heat transfer to the glass. A single gas connection, compatible mounting hardware and existing BrightFire service connections simplify installation or conversion, subject to the selected arrangement.

Features & Benefits

Internal Cooling Air Pressure
2 to 8 psi (138 to 552 mbar)
Minimum External Cooling Air
200 SCFM (≈ 322 Nm³/h)
Internal Cooling Air Flow
7 to 14 SCFM (11 to 23 Nm³/h)
Fuel Inlet Connections
Size B: 3 in NPT/Quick Disconnect|Size G/M: 2 in NPT/Quick Disconnect
Cooling Air Connection
1/2 in quick‑disconnect
Atomizing Air Pressure
30 to 40 psi (2.1 to 2.8 bar)
Heavy Oil Limitation
Max 100 SSU viscosity at burner
Burner Length Range
17 to 36 in. (432 to 914 mm)
Gas Inlet Pressure
0.5 to 7 psi (34.5 to 482.6 mbar), input‑dependent
Combustion Concept
High‑velocity flame with adjustable flame angle
Atomizing Air Flow
13 to 66 SCFM (≈ 21 to 106 Nm³/h) (Oil)
Product Category
High‑intensity industrial burner
Oil Firing Range
Size B: 11-28 MMBtu/h|Size G: 2-10 MMBtu/h|Size M: 5-21 MMBtu/h
Fuel Capability
Gas and oil (oil with atomizing air insert)
Capacity Range
Size B: 10-31 MMBtu/h (2931-9085 kW)|Size G: 2-10 MMBtu/h (586-2931 kW)|Size M: 5-17 MMBtu/h (1465-4982 kW)
Flame Spread
22 deg nominal, adjustable ±4 deg via block bore sizing
Burner Type
Adjustable, low NOx, air-fuel burner
  • Independent flow and area adjustment improves control of glass heat input.
  • Compatible mounting and service connections simplify conversion.

Applications

  • Regenerative glass furnaces

Detailed capabilities

Separate flow and area adjustment

BrightFire 200 adds gas-flow adjustment to area adjustment so the operator can change flame geometry and the location of heat input in the glass melt. Nozzle combinations tailor the burner to the furnace. Existing BrightFire gas/cooling-air interfaces and compatible mounting parts simplify conversion. The source associates improved transfer with lower fuel use and improved glass quality, with adjustment still required for the actual furnace.

Manufacturer reference ↗

Features and benefits

  • Independent flow and area adjustment improves control of glass heat input.
  • Compatible mounting and service connections simplify conversion.

Manufacturer reference ↗

Published application context

  • Regenerative glass furnaces

Manufacturer reference ↗

Specifications

Overview

Models
Size G, Size M, Size B
Product Category
High‑intensity industrial burner
Burner Type
Adjustable, low NOx, air-fuel burner

Pressure Specifications

Internal Cooling Air Pressure
2 to 8 psi (138 to 552 mbar)
Atomizing Air Pressure
30 to 40 psi (2.1 to 2.8 bar)
Gas Inlet Pressure
0.5 to 7 psi (34.5 to 482.6 mbar), input‑dependent

Combustion Air, Blower & Emissions Specifications

Minimum External Cooling Air
200 SCFM (≈ 322 Nm³/h)

Air & Combustion Air Specifications

Internal Cooling Air Flow
7 to 14 SCFM (11 to 23 Nm³/h)
Atomizing Air Flow
13 to 66 SCFM (≈ 21 to 106 Nm³/h) (Oil)

Connections & Interfaces

Fuel Inlet Connections
Size B: 3 in NPT/Quick Disconnect; Size G/M: 2 in NPT/Quick Disconnect
Cooling Air Connection
1/2 in quick‑disconnect

Fuel, Gas & Media Specifications

Heavy Oil Limitation
Max 100 SSU viscosity at burner
Fuel Capability
Gas and oil (oil with atomizing air insert)

Dimensions & Length Specifications

Burner Length Range
17 to 36 in. (432 to 914 mm)

Combustion Design & Characteristics

Combustion Concept
High‑velocity flame with adjustable flame angle

Combustion, Fuel & Mixing Sub‑Systems

Oil Firing Range
Size B: 11-28 MMBtu/h; Size G: 2-10 MMBtu/h; Size M: 5-21 MMBtu/h

Processing & Performance Metrics

Capacity Range
Size B: 10-31 MMBtu/h (2931-9085 kW); Size G: 2-10 MMBtu/h (586-2931 kW); Size M: 5-17 MMBtu/h (1465-4982 kW)

Ignition, Flame & Supervision Specifications

Flame Spread
22 deg nominal, adjustable ±4 deg via block bore sizing

Applications & Compatibility

Applications
Furnaces, Kilns, Incinerators, High‑Temperature Industrial Heating
BrightFire 200 — manufacturer page values
ParameterPublished value / configuration
ModelsSize G, Size M, Size B
Product CategoryHigh‑intensity industrial burner
Burner TypeAdjustable, low NOx, air-fuel burner
Internal Cooling Air Pressure2 to 8 psi (138 to 552 mbar)
Atomizing Air Pressure30 to 40 psi (2.1 to 2.8 bar)
Gas Inlet Pressure0.5 to 7 psi (34.5 to 482.6 mbar), input‑dependent
Minimum External Cooling Air200 SCFM (≈ 322 Nm³/h)
Internal Cooling Air Flow7 to 14 SCFM (11 to 23 Nm³/h)
Atomizing Air Flow13 to 66 SCFM (≈ 21 to 106 Nm³/h) (Oil)
Fuel Inlet ConnectionsSize B: 3 in NPT/Quick Disconnect; Size G/M: 2 in NPT/Quick Disconnect
Cooling Air Connection1/2 in quick‑disconnect
Heavy Oil LimitationMax 100 SSU viscosity at burner
Fuel CapabilityGas and oil (oil with atomizing air insert)
Burner Length Range17 to 36 in. (432 to 914 mm)
Combustion ConceptHigh‑velocity flame with adjustable flame angle
Oil Firing RangeSize B: 11-28 MMBtu/h; Size G: 2-10 MMBtu/h; Size M: 5-21 MMBtu/h
Capacity RangeSize B: 10-31 MMBtu/h (2931-9085 kW); Size G: 2-10 MMBtu/h (586-2931 kW); Size M: 5-17 MMBtu/h (1465-4982 kW)
Flame Spread22 deg nominal, adjustable ±4 deg via block bore sizing
ApplicationsFurnaces, Kilns, Incinerators, High‑Temperature Industrial Heating

Values retain manufacturer model qualifications. Review Honeywell specifications ↗

Part Number

Published part numbers

10 parts

Part NumberDescriptionEnquiry
015139WSHR,THRST,0.88 OD X 0.386 ID,0.125 THK,Request quotation
015155FSTNR,SCR,CAP,HEX,3/8 16 X 0.75 IN.,FULLRequest quotation
018250-3NUT,GLND,PKG,VLV ASY,BRT200 BRNR,G SZ,RERequest quotation
018250-4NUT,GLND,PKG,VLV ASY,BRT200 BRNR,M SZ,RERequest quotation
018250-6NUT,GLND,PKG,VLV ASY,BRT200 BRNR,B SZ,RERequest quotation
018309-1SCR,ADJ LEAD,ASY,4.88 IN. SCR LENG,6.12Request quotation
018309-2SCR,ADJ LEAD,ASY,5.38 IN. SCR LENG,6.62Request quotation
018309-3SCR,ADJ LEAD,ASY,6.12 IN. SCR LENG,7.38Request quotation
018309-4SCR,ADJ LEAD,ASY,2.88 IN. SCR LENG,4.12Request quotation
018311-3BOSS,AIR,BRT200,G SZ,18.25 MM BORE,1/2 IRequest quotation
Manufacturer sources

https://process.honeywell.com/us/en/products/thermal-solutions/burners-and-heat-exchangers/glass-and-oxygen-burners/brightfire-200

Last source check: 2026-11-02

BrightFire 200 Product Image · Manufacturer ownership retained; republication licence not independently confirmed

ABID Automation LTD maintains this independent product reference. Honeywell owns its product names and trademarks. Current manufacturer documentation governs specification, availability and certification.

Your next project. A clear starting point.

Tell us about your facility and what you need to achieve.