Glass & Oxygen Burners
PrimeFire 100
PrimeFire 100 provides an adjustable conventional-shaped oxy-fuel flame for glass furnaces, including higher-capacity float-glass duties.
PrimeFire 100 provides an adjustable conventional-shaped oxy-fuel flame for glass furnaces, including higher-capacity float-glass duties. Gas and light/heavy oil configurations extend fuel flexibility. Flame coverage can be set around melter width and temperature needs, while the source attributes efficiency, refractory-life and emissions benefits to the resulting heat distribution.
Features & Benefits
- Typical Cooling Flow
- ~1000 SCFH (27 Nm³/h) oxygen (Offline)
- Product Category
- Oxygen‑fuel industrial burner
- Primary Fuels
- Natural Gas, Light Oil, Heavy Oil (fuel switching supported)
- Operating Ratio
- Typical oxygen‑to‑gas ratio ≈2.0:1 at low fire (gas‑dependent) (Startup)
- Emissions
- Lower emissions (NOx and particulates)
- Combustion Concept
- Oxygen‑fuel burner with conventional flame shape
- Capacity Range
- Extra Large - 5,000,000-20,000,000 Btu/h (1464-5857 kW)|Large Size - 2,000,000-8,000,000 Btu/h (586-2343 kW)|Medium Size - 750,000-3,000,000 Btu/h (220-878 kW)|Small Size - 250,000-1,000,000 Btu/h (73-293 kW)
- Adjustable coverage supports even glass heating and refractory life.
Applications
- Glass melting
- Float-glass furnaces
Detailed capabilities
Glass coverage and oil-service features
PrimeFire 100 adjusts flame coverage around melter size and the temperature profile. Its high-luminosity conventional flame and multiple-fuel capability support glass melting, including float glass. The oil configuration has separately described atomizing-pressure and nozzle/block-temperature advantages, while common components permit fuel changes. Those oil-service features must remain associated with the corresponding fuel arrangement rather than every gas-only burner.
Features and benefits
- Adjustable coverage supports even glass heating and refractory life.
Published application context
- Glass melting
- Float-glass furnaces
Applications & Compatibility
- Applications
- Glass Furnaces, Copper Frit, Aluminum Melting, Steel, Ceramics
Performance, Flow & Capacity
- Typical Cooling Flow
- ~1000 SCFH (27 Nm³/h) oxygen (Offline)
Overview
- Product Category
- Oxygen‑fuel industrial burner
Fuel, Gas & Media Specifications
- Primary Fuels
- Natural Gas, Light Oil, Heavy Oil (fuel switching supported)
Control, Logic & Functional Behavior
- Operating Ratio
- Typical oxygen‑to‑gas ratio ≈2.0:1 at low fire (gas‑dependent) (Startup)
Processing & Performance Metrics
- Emissions
- Lower emissions (NOx and particulates)
- Capacity Range
- Extra Large - 5,000,000-20,000,000 Btu/h (1464-5857 kW); Large Size - 2,000,000-8,000,000 Btu/h (586-2343 kW); Medium Size - 750,000-3,000,000 Btu/h (220-878 kW); Small Size - 250,000-1,000,000 Btu/h (73-293 kW)
Combustion Design & Characteristics
- Combustion Concept
- Oxygen‑fuel burner with conventional flame shape
| Parameter | Published value / configuration |
|---|---|
| Applications | Glass Furnaces, Copper Frit, Aluminum Melting, Steel, Ceramics |
| Typical Cooling Flow | ~1000 SCFH (27 Nm³/h) oxygen (Offline) |
| Product Category | Oxygen‑fuel industrial burner |
| Primary Fuels | Natural Gas, Light Oil, Heavy Oil (fuel switching supported) |
| Operating Ratio | Typical oxygen‑to‑gas ratio ≈2.0:1 at low fire (gas‑dependent) (Startup) |
| Emissions | Lower emissions (NOx and particulates) |
| Capacity Range | Extra Large - 5,000,000-20,000,000 Btu/h (1464-5857 kW); Large Size - 2,000,000-8,000,000 Btu/h (586-2343 kW); Medium Size - 750,000-3,000,000 Btu/h (220-878 kW); Small Size - 250,000-1,000,000 Btu/h (73-293 kW) |
| Combustion Concept | Oxygen‑fuel burner with conventional flame shape |
Values retain manufacturer model qualifications. Review Honeywell specifications ↗
Part Number
Published part numbers
10 parts
| Part Number | Description | Enquiry |
|---|---|---|
| 014559 | BRNR,PRIMEFIRE100,OXY,DUAL FUEL,1 4MM BT | Request quotation |
| 018766 | GSKT,FLG,MTG,PF100,1 4MM BTU/HR. | Request quotation |
| 018901 | CMBSTR,RFRCT,PRMFR,PF100,0.25 1 MMBTU/HR | Request quotation |
| 019114 | FLG,MTG,BRNR BLCK,PRMFR 100 WAS 0201 09 | Request quotation |
| 019121 | TIP,GAS,PF100,2 8MM BTU/HR,DUAL FUEL,OIL | Request quotation |
| 019123 | TIP,GAS,PF100,5 20MM BTU/HR,GAS ONLY,MAT | Request quotation |
| 019124 | TIP,OXY,PF100,2 8MM BTU/HR,GAS/OIL/DUAL | Request quotation |
| 019125 | TIP,OXY,PF100,5 20MM BTU/HR,GAS/OIL/DUAL | Request quotation |
| 019143 | GSKT,BRNR,OXY/DUAL FUEL,PF100,2 8MM BTU/ | Request quotation |
| 019369 | VTRI ASY PF100 1 4MM BTU BRNR | Request quotation |
Manufacturer sources
Last source check: 2026-11-02
PrimeFire 100 Product Image · Manufacturer ownership retained; republication licence not independently confirmed
ABID Automation LTD maintains this independent product reference. Honeywell owns its product names and trademarks. Current manufacturer documentation governs specification, availability and certification.