Fire & Life Safety · Building Systems · Industrial Automation [email protected] +880 1347 561 256
Honeywell Process Measurement & Control

Glass & Oxygen Burners

OXY-THERM TITAN

OXY-THERM TITAN develops a compact oxy-fuel flame through a refractory throat for high-temperature processes.

OXY-THERM TITAN develops a compact oxy-fuel flame through a refractory throat for high-temperature processes. Its mounting and flame geometry suit down-fired duties such as ladle heating, as well as rotary melters, incineration and process heating. A sealed, self-cooling design and published 8:1 turndown support application flexibility.

Features & Benefits

Turndown Ratio
8:1
Process Temperature Range
Up to 3000 deg F (1649 deg C) with standard block
Pilot Options
Air pilot; Oxy-fuel pilot
Nozzle Material
310 Stainless Steel
Mounting Options
Vertical/down-fired capable, door-mounted, flange/block design
Fuel Type
Any fuel gas, including up to 20% hydrogen/80% natural gas blend
Flame Supervision
Flame rod not available|Provision for UV scanner via 3/4 in NPT port
Emissions
Exact performance varies by application; consult Honeywell Maxon
Cooling Requirements
Provide small cooling flow (clean, dry air or oxygen) whenever hot and not firing
Capacity Range
1-1/2 in: 2 to 12 MBTU/h (529 to 3173 kW)|2 in: 10-30 MBTU/h (2644 to 7932 kW)(Gas)
Burner Type
Compact flame oxygen-fuel burner
Burner Sizes
1-1/2 and 2 in
Burner Material
304 Stainless Steel
Block Material
Alumina/Mullite refractory
  • Compact geometry suits down-fired installations.
  • A sealed self-cooling body limits infiltration and maintenance.

Applications

  • Ladle heating
  • Reheat furnaces
  • Rotary hearths
  • Forge furnaces
  • Reaction furnaces
  • High-temperature sealed processes

Detailed capabilities

Compact flame for down-fired processes

OXY-THERM TITAN mixes oxygen around the fuel nozzle and discharges through a refractory throat into a tightly wrapped flame. The shape and mounting support downward firing at higher capacities, including ladle duties. A sealed self-cooling body limits infiltration and cooling maintenance, while the published turndown supports temperature control. Rotary melting, incineration and sealed high-temperature processes are additional stated uses.

Manufacturer reference ↗

Features and benefits

  • Compact geometry suits down-fired installations.
  • A sealed self-cooling body limits infiltration and maintenance.

Manufacturer reference ↗

Published application context

  • Ladle heating
  • Reheat furnaces
  • Rotary hearths
  • Forge furnaces
  • Reaction furnaces
  • High-temperature sealed processes

Manufacturer reference ↗

Specifications

Applications & Compatibility

Applications
Ladle heating, reheat furnaces, rotary hearths, forge furnaces, reaction furnaces, waste incinerators, high-temp sealed processes

Performance, Flow & Capacity

Turndown Ratio
8:1

Operating/Process Temperature Ranges

Process Temperature Range
Up to 3000 deg F (1649 deg C) with standard block

Combustion, Fuel & Mixing Sub‑Systems

Pilot Options
Air pilot; Oxy-fuel pilot

Material Specifications

Nozzle Material
310 Stainless Steel
Burner Material
304 Stainless Steel
Block Material
Alumina/Mullite refractory

Installation & Mounting Specifications

Mounting Options
Vertical/down-fired capable, door-mounted, flange/block design

Fuel, Gas & Media Specifications

Fuel Type
Any fuel gas, including up to 20% hydrogen/80% natural gas blend

Ignition, Flame & Supervision Specifications

Flame Supervision
Flame rod not available; Provision for UV scanner via 3/4 in NPT port
Cooling Requirements
Provide small cooling flow (clean, dry air or oxygen) whenever hot and not firing

Processing & Performance Metrics

Emissions
Exact performance varies by application; consult Honeywell Maxon
Capacity Range
1-1/2 in: 2 to 12 MBTU/h (529 to 3173 kW); 2 in: 10-30 MBTU/h (2644 to 7932 kW)(Gas)

Overview

Burner Type
Compact flame oxygen-fuel burner

Dimensions & Size Specifications

Burner Sizes
1-1/2 and 2 in
OXY-THERM TITAN — manufacturer page values
ParameterPublished value / configuration
ApplicationsLadle heating, reheat furnaces, rotary hearths, forge furnaces, reaction furnaces, waste incinerators, high-temp sealed processes
Turndown Ratio8:1
Process Temperature RangeUp to 3000 deg F (1649 deg C) with standard block
Pilot OptionsAir pilot; Oxy-fuel pilot
Nozzle Material310 Stainless Steel
Burner Material304 Stainless Steel
Block MaterialAlumina/Mullite refractory
Mounting OptionsVertical/down-fired capable, door-mounted, flange/block design
Fuel TypeAny fuel gas, including up to 20% hydrogen/80% natural gas blend
Flame SupervisionFlame rod not available; Provision for UV scanner via 3/4 in NPT port
Cooling RequirementsProvide small cooling flow (clean, dry air or oxygen) whenever hot and not firing
EmissionsExact performance varies by application; consult Honeywell Maxon
Capacity Range1-1/2 in: 2 to 12 MBTU/h (529 to 3173 kW); 2 in: 10-30 MBTU/h (2644 to 7932 kW)(Gas)
Burner TypeCompact flame oxygen-fuel burner
Burner Sizes1-1/2 and 2 in

Values retain manufacturer model qualifications. Review Honeywell specifications ↗

Part Number

Published part numbers

10 parts

Part NumberDescriptionEnquiry
1080450GAS NZL CAPRequest quotation
1080453BSHGRequest quotation
1080455GAS INS ASYRequest quotation
1080493GAS SPUDRequest quotation
1080631HSG GSKTRequest quotation
1081774FURN MTG PLTRequest quotation
10885051.5" BRNR HSG GSKTRequest quotation
10885171.5" GAS INS MTG PLTRequest quotation
10885181.5" GAS TIP BLNKRequest quotation
10885191.5" GAS TIPRequest quotation
Manufacturer sources

https://process.honeywell.com/us/en/products/thermal-solutions/burners-and-heat-exchangers/glass-and-oxygen-burners/oxy-therm-titan

Last source check: 2026-11-02

Oxytherm Titan - Primary Image · Manufacturer ownership retained; republication licence not independently confirmed

OXY-THERM Titan Product Image · Manufacturer ownership retained; republication licence not independently confirmed

ABID Automation LTD maintains this independent product reference. Honeywell owns its product names and trademarks. Current manufacturer documentation governs specification, availability and certification.

Your next project. A clear starting point.

Tell us about your facility and what you need to achieve.

CallSend enquiry