Glass & Oxygen Burners
OXY-THERM LE Natural Gas Burners
OXY-THERM LE stages oxygen to reduce NOx in industrial oxy-fuel heating.
OXY-THERM LE stages oxygen to reduce NOx in industrial oxy-fuel heating. It accepts the stated gaseous fuels and light-to-heavy oils, with conversion by nozzle change. The design limits flame lofting and permits nozzle removal during furnace operation; the published emissions reductions compare it with conventional oxy-gas or oxy-oil burners.
Features & Benefits
- Process Temperature Range
- Up to 3200 deg F (1760 deg C) with standard blocks
- Conversion Capability
- Nozzles can be removed during operation; quick gas to oil conversion by changing the burner nozzle
- Cooling Requirements
- Provide clean, dry air or oxygen for cooling when burner is in a hot atmosphere and not firing
- Mounting Options
- Do not install down-fired; support piping; use flexible connectors to reduce stress
- Nozzle Material
- 440F Stainless Steel
- Burner Material
- Bronze casting SAE 622
- Turndown Ratio
- 5:1 (gas), 4-5:1 (oil)
- Oxygen Staging
- Optimizes heat transfer and flame volume|Patented oxygen staging to reduce Nox
- Oil Capability
- Light and heavy fuel oils (via nozzle change)
- Capacity Range
- Gas - Series 600: 0.2-2.7 MBTU/h; Series 900: 1.5-11 MBTU/h; Series 1200: 5-13 MBTU/h (up to 15 MBTU/h possible)|Oil - 3.1-19.9 MBTU/h (sizes 70-400)
- NOx Emissions
- Extremely low NOx using patented oxygen staging
- Burner Type
- Oxygen‑fuel, low‑emissions burner
- Flame Size
- Gas - Diameter: 18 in (S600), 30 in (S900), 36 in (S1200); length per MBTU/h: 2.2-2.0 ft (S600), 2.0-1.6 ft (S900), 2.0-1.3 ft (S1200)|Oil - Diameter 18-36 in; length 6-20 ft at max output (size-dependent)
- Fuel Type
- Primary - Natural Gas, Alternate - Propane; up to 20% Hydrogen/80% fuel blend
- The nozzle can be serviced without taking the furnace out of operation.
- The flame design limits crown heating from flame lofting.
Applications
- Industrial oxy-fuel heating
Detailed capabilities
Oxygen staging, crown temperature and fuel conversion
OXY-THERM LE stages oxygen to reduce NOx and prevent flame lofting that would heat the crown. It supports the named gaseous fuels and light/heavy oil arrangements, with fuel conversion by changing the nozzle. Nozzles can be removed during operation. Reported NOx improvements compare against conventional oxy-gas or oxy-oil equipment, which are different baselines and cannot be combined into one general savings statement.
Features and benefits
- The nozzle can be serviced without taking the furnace out of operation.
- The flame design limits crown heating from flame lofting.
Published application context
- Industrial oxy-fuel heating
Overview
- Models
- LE 600, LE 900, LE 1200
- Burner Type
- Oxygen‑fuel, low‑emissions burner
Operating/Process Temperature Ranges
- Process Temperature Range
- Up to 3200 deg F (1760 deg C) with standard blocks
Processing & Performance Metrics
- Conversion Capability
- Nozzles can be removed during operation; quick gas to oil conversion by changing the burner nozzle
- Capacity Range
- Gas - Series 600: 0.2-2.7 MBTU/h; Series 900: 1.5-11 MBTU/h; Series 1200: 5-13 MBTU/h (up to 15 MBTU/h possible); Oil - 3.1-19.9 MBTU/h (sizes 70-400)
- NOx Emissions
- Extremely low NOx using patented oxygen staging
Ignition, Flame & Supervision Specifications
- Cooling Requirements
- Provide clean, dry air or oxygen for cooling when burner is in a hot atmosphere and not firing
Installation & Mounting Specifications
- Mounting Options
- Do not install down-fired; support piping; use flexible connectors to reduce stress
Material Specifications
- Nozzle Material
- 440F Stainless Steel
- Burner Material
- Bronze casting SAE 622
Performance, Flow & Capacity
- Turndown Ratio
- 5:1 (gas), 4-5:1 (oil)
Combustion, Mixing & Fuel Dynamics
- Oxygen Staging
- Optimizes heat transfer and flame volume; Patented oxygen staging to reduce Nox
Fuel, Gas & Media Specifications
- Oil Capability
- Light and heavy fuel oils (via nozzle change)
- Fuel Type
- Primary - Natural Gas, Alternate - Propane; up to 20% Hydrogen/80% fuel blend
Applications & Compatibility
- Applications
- Glass Furnaces, Day Tanks, Incinerators, Metal Melting Furnaces, Reheat Furnaces, Kilns; High-Temp Applications
Dimensions & Size Specifications
- Flame Size
- Gas - Diameter: 18 in (S600), 30 in (S900), 36 in (S1200); length per MBTU/h: 2.2-2.0 ft (S600), 2.0-1.6 ft (S900), 2.0-1.3 ft (S1200); Oil - Diameter 18-36 in; length 6-20 ft at max output (size-dependent)
| Parameter | Published value / configuration |
|---|---|
| Models | LE 600, LE 900, LE 1200 |
| Burner Type | Oxygen‑fuel, low‑emissions burner |
| Process Temperature Range | Up to 3200 deg F (1760 deg C) with standard blocks |
| Conversion Capability | Nozzles can be removed during operation; quick gas to oil conversion by changing the burner nozzle |
| Capacity Range | Gas - Series 600: 0.2-2.7 MBTU/h; Series 900: 1.5-11 MBTU/h; Series 1200: 5-13 MBTU/h (up to 15 MBTU/h possible); Oil - 3.1-19.9 MBTU/h (sizes 70-400) |
| NOx Emissions | Extremely low NOx using patented oxygen staging |
| Cooling Requirements | Provide clean, dry air or oxygen for cooling when burner is in a hot atmosphere and not firing |
| Mounting Options | Do not install down-fired; support piping; use flexible connectors to reduce stress |
| Nozzle Material | 440F Stainless Steel |
| Burner Material | Bronze casting SAE 622 |
| Turndown Ratio | 5:1 (gas), 4-5:1 (oil) |
| Oxygen Staging | Optimizes heat transfer and flame volume; Patented oxygen staging to reduce Nox |
| Oil Capability | Light and heavy fuel oils (via nozzle change) |
| Fuel Type | Primary - Natural Gas, Alternate - Propane; up to 20% Hydrogen/80% fuel blend |
| Applications | Glass Furnaces, Day Tanks, Incinerators, Metal Melting Furnaces, Reheat Furnaces, Kilns; High-Temp Applications |
| Flame Size | Gas - Diameter: 18 in (S600), 30 in (S900), 36 in (S1200); length per MBTU/h: 2.2-2.0 ft (S600), 2.0-1.6 ft (S900), 2.0-1.3 ft (S1200); Oil - Diameter 18-36 in; length 6-20 ft at max output (size-dependent) |
Values retain manufacturer model qualifications. Review Honeywell specifications ↗
Part Number
Published part numbers
10 parts
| Part Number | Description | Enquiry |
|---|---|---|
| 1034283 | 600 OXY BRNR BLCK FRM | Request quotation |
| 1035854 | 70LPH 907 OIL TB ASY W/MOD+ | Request quotation |
| 1039706 | 900 OXY BRNR BLCK FRM | Request quotation |
| 1060205 | 900, 1200 BLNK PLT | Request quotation |
| 1062199 | SERV PLT | Request quotation |
| 1066594 | 600 OT LE BLNK PLT | Request quotation |
| 1079804 | OXY PLT BDY | Request quotation |
| 1092365 | 600 LE ZIRC BLCK, FRM ASY+ | Request quotation |
| 1092369 | 600 GAS NZL BLANK 310SS | Request quotation |
| 1092372 | 600 FRM, FACE MNT | Request quotation |
Manufacturer sources
Last source check: 2026-11-02
OXY-THERM LE Product Image · Manufacturer ownership retained; republication licence not independently confirmed
OXY-THERM LE Product Image 1 · Manufacturer ownership retained; republication licence not independently confirmed
ABID Automation LTD maintains this independent product reference. Honeywell owns its product names and trademarks. Current manufacturer documentation governs specification, availability and certification.
Your next project. A clear starting point.
Tell us about your facility and what you need to achieve.