Fire & Life Safety · Building Systems · Industrial Automation [email protected] +880 1347 561 256
Honeywell Process Measurement & Control

Glass & Oxygen Burners

OXY-THERM LE Natural Gas Burners

OXY-THERM LE stages oxygen to reduce NOx in industrial oxy-fuel heating.

OXY-THERM LE stages oxygen to reduce NOx in industrial oxy-fuel heating. It accepts the stated gaseous fuels and light-to-heavy oils, with conversion by nozzle change. The design limits flame lofting and permits nozzle removal during furnace operation; the published emissions reductions compare it with conventional oxy-gas or oxy-oil burners.

Features & Benefits

Process Temperature Range
Up to 3200 deg F (1760 deg C) with standard blocks
Conversion Capability
Nozzles can be removed during operation; quick gas to oil conversion by changing the burner nozzle
Cooling Requirements
Provide clean, dry air or oxygen for cooling when burner is in a hot atmosphere and not firing
Mounting Options
Do not install down-fired; support piping; use flexible connectors to reduce stress
Nozzle Material
440F Stainless Steel
Burner Material
Bronze casting SAE 622
Turndown Ratio
5:1 (gas), 4-5:1 (oil)
Oxygen Staging
Optimizes heat transfer and flame volume|Patented oxygen staging to reduce Nox
Oil Capability
Light and heavy fuel oils (via nozzle change)
Capacity Range
Gas - Series 600: 0.2-2.7 MBTU/h; Series 900: 1.5-11 MBTU/h; Series 1200: 5-13 MBTU/h (up to 15 MBTU/h possible)|Oil - 3.1-19.9 MBTU/h (sizes 70-400)
NOx Emissions
Extremely low NOx using patented oxygen staging
Burner Type
Oxygen‑fuel, low‑emissions burner
Flame Size
Gas - Diameter: 18 in (S600), 30 in (S900), 36 in (S1200); length per MBTU/h: 2.2-2.0 ft (S600), 2.0-1.6 ft (S900), 2.0-1.3 ft (S1200)|Oil - Diameter 18-36 in; length 6-20 ft at max output (size-dependent)
Fuel Type
Primary - Natural Gas, Alternate - Propane; up to 20% Hydrogen/80% fuel blend
  • The nozzle can be serviced without taking the furnace out of operation.
  • The flame design limits crown heating from flame lofting.

Applications

  • Industrial oxy-fuel heating

Detailed capabilities

Oxygen staging, crown temperature and fuel conversion

OXY-THERM LE stages oxygen to reduce NOx and prevent flame lofting that would heat the crown. It supports the named gaseous fuels and light/heavy oil arrangements, with fuel conversion by changing the nozzle. Nozzles can be removed during operation. Reported NOx improvements compare against conventional oxy-gas or oxy-oil equipment, which are different baselines and cannot be combined into one general savings statement.

Manufacturer reference ↗

Features and benefits

  • The nozzle can be serviced without taking the furnace out of operation.
  • The flame design limits crown heating from flame lofting.

Manufacturer reference ↗

Published application context

  • Industrial oxy-fuel heating

Manufacturer reference ↗

Specifications

Overview

Models
LE 600, LE 900, LE 1200
Burner Type
Oxygen‑fuel, low‑emissions burner

Operating/Process Temperature Ranges

Process Temperature Range
Up to 3200 deg F (1760 deg C) with standard blocks

Processing & Performance Metrics

Conversion Capability
Nozzles can be removed during operation; quick gas to oil conversion by changing the burner nozzle
Capacity Range
Gas - Series 600: 0.2-2.7 MBTU/h; Series 900: 1.5-11 MBTU/h; Series 1200: 5-13 MBTU/h (up to 15 MBTU/h possible); Oil - 3.1-19.9 MBTU/h (sizes 70-400)
NOx Emissions
Extremely low NOx using patented oxygen staging

Ignition, Flame & Supervision Specifications

Cooling Requirements
Provide clean, dry air or oxygen for cooling when burner is in a hot atmosphere and not firing

Installation & Mounting Specifications

Mounting Options
Do not install down-fired; support piping; use flexible connectors to reduce stress

Material Specifications

Nozzle Material
440F Stainless Steel
Burner Material
Bronze casting SAE 622

Performance, Flow & Capacity

Turndown Ratio
5:1 (gas), 4-5:1 (oil)

Combustion, Mixing & Fuel Dynamics

Oxygen Staging
Optimizes heat transfer and flame volume; Patented oxygen staging to reduce Nox

Fuel, Gas & Media Specifications

Oil Capability
Light and heavy fuel oils (via nozzle change)
Fuel Type
Primary - Natural Gas, Alternate - Propane; up to 20% Hydrogen/80% fuel blend

Applications & Compatibility

Applications
Glass Furnaces, Day Tanks, Incinerators, Metal Melting Furnaces, Reheat Furnaces, Kilns; High-Temp Applications

Dimensions & Size Specifications

Flame Size
Gas - Diameter: 18 in (S600), 30 in (S900), 36 in (S1200); length per MBTU/h: 2.2-2.0 ft (S600), 2.0-1.6 ft (S900), 2.0-1.3 ft (S1200); Oil - Diameter 18-36 in; length 6-20 ft at max output (size-dependent)
OXY-THERM LE Natural Gas Burners — manufacturer page values
ParameterPublished value / configuration
ModelsLE 600, LE 900, LE 1200
Burner TypeOxygen‑fuel, low‑emissions burner
Process Temperature RangeUp to 3200 deg F (1760 deg C) with standard blocks
Conversion CapabilityNozzles can be removed during operation; quick gas to oil conversion by changing the burner nozzle
Capacity RangeGas - Series 600: 0.2-2.7 MBTU/h; Series 900: 1.5-11 MBTU/h; Series 1200: 5-13 MBTU/h (up to 15 MBTU/h possible); Oil - 3.1-19.9 MBTU/h (sizes 70-400)
NOx EmissionsExtremely low NOx using patented oxygen staging
Cooling RequirementsProvide clean, dry air or oxygen for cooling when burner is in a hot atmosphere and not firing
Mounting OptionsDo not install down-fired; support piping; use flexible connectors to reduce stress
Nozzle Material440F Stainless Steel
Burner MaterialBronze casting SAE 622
Turndown Ratio5:1 (gas), 4-5:1 (oil)
Oxygen StagingOptimizes heat transfer and flame volume; Patented oxygen staging to reduce Nox
Oil CapabilityLight and heavy fuel oils (via nozzle change)
Fuel TypePrimary - Natural Gas, Alternate - Propane; up to 20% Hydrogen/80% fuel blend
ApplicationsGlass Furnaces, Day Tanks, Incinerators, Metal Melting Furnaces, Reheat Furnaces, Kilns; High-Temp Applications
Flame SizeGas - Diameter: 18 in (S600), 30 in (S900), 36 in (S1200); length per MBTU/h: 2.2-2.0 ft (S600), 2.0-1.6 ft (S900), 2.0-1.3 ft (S1200); Oil - Diameter 18-36 in; length 6-20 ft at max output (size-dependent)

Values retain manufacturer model qualifications. Review Honeywell specifications ↗

Part Number

Published part numbers

10 parts

Part NumberDescriptionEnquiry
1034283600 OXY BRNR BLCK FRMRequest quotation
103585470LPH 907 OIL TB ASY W/MOD+Request quotation
1039706900 OXY BRNR BLCK FRMRequest quotation
1060205900, 1200 BLNK PLTRequest quotation
1062199SERV PLTRequest quotation
1066594600 OT LE BLNK PLTRequest quotation
1079804OXY PLT BDYRequest quotation
1092365600 LE ZIRC BLCK, FRM ASY+Request quotation
1092369600 GAS NZL BLANK 310SSRequest quotation
1092372600 FRM, FACE MNTRequest quotation
Manufacturer sources

https://process.honeywell.com/us/en/products/thermal-solutions/burners-and-heat-exchangers/glass-and-oxygen-burners/oxy-therm-le-natural-gas-burners

Last source check: 2026-11-02

OXY-THERM LE Product Image · Manufacturer ownership retained; republication licence not independently confirmed

OXY-THERM LE Product Image 1 · Manufacturer ownership retained; republication licence not independently confirmed

ABID Automation LTD maintains this independent product reference. Honeywell owns its product names and trademarks. Current manufacturer documentation governs specification, availability and certification.

Your next project. A clear starting point.

Tell us about your facility and what you need to achieve.

CallSend enquiry