Glass & Oxygen Burners
OXY-THERM® 300 Series
OXY-THERM 300 uses oxygen combustion to limit nitrogen entering the flame and to increase available heat.
OXY-THERM 300 uses oxygen combustion to limit nitrogen entering the flame and to increase available heat. The page describes two block shapes, self-cooling construction and removable nozzles for service. Its title and opening refer to oil firing, while later text describes gaseous fuels; fuel configuration must therefore follow the exact burner documentation.
Features & Benefits
- Maximum Furnace Temperature
- Up to 2800 deg F with standard block (higher temp options on request)
- Oxygen to Fuel Ratio
- Natural Gas: 2.1:1; Propane: 5.2:1 (volumetric)
- Cooling Requirements
- Provide cooling flow (clean, dry air or oxygen) whenever burner is hot and not firing
- Fuel Pressure Range
- Natural Gas - 6.2 psig, Propane - 2.5 psig
- Flame Supervision
- UV Scanner (adapter required for direct spark versions)
- Ignition Options
- Direct spark option; UV scanner adapter for direct spark versions
- Oxygen Pressure
- 2.9 in wc (max capacity)
- Capacity Range
- 5,000 to 300,000 Btu/h
- Block Material
- Alumina/Zirconia/Silica (AZS
- Block Options
- 3 in square or 3 in round AZS refractory block
- Oxygen Flow
- 630 scfh (Max Fire)
- Burner Type
- High-temperature oxygen-fuel burner
- Flame Size
- Visible in open air: diameter 1-6 in; length 36 in
- Fuel Type
- Natural gas or propane (see typical data); other clean gaseous fuels per application
- Oxygen firing reduces exhaust-gas volume and increases available heat.
- The self-cooled design avoids water-cooling hardware.
Applications
- Industrial oxy-fuel heating
Detailed capabilities
Oxygen combustion and heat delivery
Using oxygen removes much of the atmospheric nitrogen that would otherwise pass through the flame and exhaust. Honeywell links this to lower NOx formation, higher available heat and a smaller flue-gas-handling requirement. The design is self-cooled rather than water-cooled and offers two block shapes. The stated 300,000 Btu/hr maximum applies to this series; it is not the capacity of all OXY-THERM families.
Service access and fuel-description qualification
The nozzle can be removed while the furnace remains operating, reducing the need for a shutdown for that work. The page is internally inconsistent in how it introduces fuel service: the heading/opening refer to an oil-fired burner, while the explanatory text describes gaseous fuels, including gases unstable in air combustion. The exact gas/oil configuration must therefore be checked in the selected burner's technical information before applying either description.
Features and benefits
- Oxygen firing reduces exhaust-gas volume and increases available heat.
- The self-cooled design avoids water-cooling hardware.
Published application context
- Industrial oxy-fuel heating
Maximum/Minimum Temperature Limits
- Maximum Furnace Temperature
- Up to 2800 deg F with standard block (higher temp options on request)
Combustion, Mixing & Fuel Dynamics
- Oxygen to Fuel Ratio
- Natural Gas: 2.1:1; Propane: 5.2:1 (volumetric)
- Oxygen Flow
- 630 scfh (Max Fire)
Ignition, Flame & Supervision Specifications
- Cooling Requirements
- Provide cooling flow (clean, dry air or oxygen) whenever burner is hot and not firing
- Flame Supervision
- UV Scanner (adapter required for direct spark versions)
- Ignition Options
- Direct spark option; UV scanner adapter for direct spark versions
Pressure Specifications
- Fuel Pressure Range
- Natural Gas - 6.2 psig, Propane - 2.5 psig
- Oxygen Pressure
- 2.9 in wc (max capacity)
Processing & Performance Metrics
- Capacity Range
- 5,000 to 300,000 Btu/h
Material Specifications
- Block Material
- Alumina/Zirconia/Silica (AZS
Mechanical Design & Adjustment Characteristics
- Block Options
- 3 in square or 3 in round AZS refractory block
Applications & Compatibility
- Applications
- Converted regenerative-type furnaces and melters, unit melters, laboratory furnaces, non-ferrous melting and recovery, high-temp applications with focused flame
Overview
- Burner Type
- High-temperature oxygen-fuel burner
Dimensions & Size Specifications
- Flame Size
- Visible in open air: diameter 1-6 in; length 36 in
Fuel, Gas & Media Specifications
- Fuel Type
- Natural gas or propane (see typical data); other clean gaseous fuels per application
| Parameter | Published value / configuration |
|---|---|
| Maximum Furnace Temperature | Up to 2800 deg F with standard block (higher temp options on request) |
| Oxygen to Fuel Ratio | Natural Gas: 2.1:1; Propane: 5.2:1 (volumetric) |
| Oxygen Flow | 630 scfh (Max Fire) |
| Cooling Requirements | Provide cooling flow (clean, dry air or oxygen) whenever burner is hot and not firing |
| Flame Supervision | UV Scanner (adapter required for direct spark versions) |
| Ignition Options | Direct spark option; UV scanner adapter for direct spark versions |
| Fuel Pressure Range | Natural Gas - 6.2 psig, Propane - 2.5 psig |
| Oxygen Pressure | 2.9 in wc (max capacity) |
| Capacity Range | 5,000 to 300,000 Btu/h |
| Block Material | Alumina/Zirconia/Silica (AZS |
| Block Options | 3 in square or 3 in round AZS refractory block |
| Applications | Converted regenerative-type furnaces and melters, unit melters, laboratory furnaces, non-ferrous melting and recovery, high-temp applications with focused flame |
| Burner Type | High-temperature oxygen-fuel burner |
| Flame Size | Visible in open air: diameter 1-6 in; length 36 in |
| Fuel Type | Natural gas or propane (see typical data); other clean gaseous fuels per application |
Values retain manufacturer model qualifications. Review Honeywell specifications ↗
Part Number
Published part numbers
10 parts
| Part Number | Description | Enquiry |
|---|---|---|
| 1034891 | OXY PIPE | Request quotation |
| 1035017 | SQ RFRCT BLCK,FRM ASY | Request quotation |
| 1035027 | 300 OXY-THERM SQ ASY | Request quotation |
| 1035453 | 300 OXY-THERM RD ASY | Request quotation |
| 1035717 | 300 OXY-THERM RD SLF-IGN ASY | Request quotation |
| 1035759 | 300 OXY-THERM SQ SLF-IGN ASY | Request quotation |
| 1042941 | BRNR INS ASY | Request quotation |
| 1042942 | BRNR INS SLF-IGN ASY | Request quotation |
| 1043970 | 300 OXY-THERM BKPLT GSKT | Request quotation |
| 1048182 | INSL BLCK | Request quotation |
Manufacturer sources
Last source check: 2026-11-02
OXY-THERM® 300 Series · Manufacturer ownership retained; republication licence not independently confirmed
ABID Automation LTD maintains this independent product reference. Honeywell owns its product names and trademarks. Current manufacturer documentation governs specification, availability and certification.
Your next project. A clear starting point.
Tell us about your facility and what you need to achieve.