Glass & Oxygen Burners
Next Generation PrimeFire FH
Next-generation PrimeFire FH combines an oxy-fuel burner and matched block for container, e-glass and wool-glass forehearths.
Next-generation PrimeFire FH combines an oxy-fuel burner and matched block for container, e-glass and wool-glass forehearths. Natural-gas versions come in three capacity groups with pipe, hose and fitting choices. Fused Mullite or AZS blocks address application needs; reduced buildup and cooler operation are compared with air-fuel premix equipment.
Features & Benefits
- Fuel Efficiency Improvement
- Up to 60% fuel reduction vs air‑fuel pre‑mix
- NOx Reduction Method
- Up to 80% vs air‑fuel pre‑mix
- Maintenance Interval
- Very low/maintenance‑free design
- Cooling Requirements
- Clean dry air, nitrogen, or oxygen
- Pipe Length Options
- 10 to 24 inch in 2-inch increments
- Inlet Orientation
- Oxygen inlet at 90 deg to fuel inlet
- Block Dimensions
- 5 x 5 x 9 in
- Connection Type
- With or without NPT fittings
- Burner Material
- 300‑series stainless steel gas tip and oxygen nozzle
- Block Material
- Fused Mullite, AZS
- Flame Length
- FH0517 - 3 to 7 in, FH0935 - 5 to 10 in, FH1350 - 7 to 12 in
- Burner Type
- Oxygen burner for forehearth applications
- Fuel Type
- Natural Gas, Hydrogen blend (up to 20% H2/80% NG)
- Fuel Flow
- FH0517 - 5 to 17 SCFH, FH0935 - 9 to 35 SCFH, FH1350 - 13 to 50 SCFH
- Cooler operation and reduced residue buildup lower maintenance demand.
- The manufacturer reports lower fuel use and NOx relative to air-fuel forehearth equipment.
Applications
- Container-glass forehearths
- E-glass forehearths
- Wool/c-glass forehearths
Detailed capabilities
Burner and block are configured together
PrimeFire FH is selected as a matched natural-gas burner/block arrangement for glass forehearths. Its three published flow groups are 5–17, 9–35 and 13–50 SCFH. Choices include standard pipe lengths, fittings and hoses. Fused Mullite or AZS blocks address different customer applications, so block material is a design selection rather than a common construction across all three burner groups.
Compared with air-fuel forehearth equipment
The design runs the burner and block cooler and limits circulating glass residue around the nozzles. Honeywell associates these changes with less maintenance and up to 50% longer life. The stated NOx and fuel reductions use air-fuel forehearth solutions as their comparison, rather than a universal baseline for every plant. Flame length shortens as firing is reduced, which matters when matching the flame to the forehearth geometry.
Features and benefits
- Cooler operation and reduced residue buildup lower maintenance demand.
- The manufacturer reports lower fuel use and NOx relative to air-fuel forehearth equipment.
Published application context
- Container-glass forehearths
- E-glass forehearths
- Wool/c-glass forehearths
Overview
- Models
- FH0517, FH0935, FH1350
- Burner Type
- Oxygen burner for forehearth applications
Performance Specifications
- Fuel Efficiency Improvement
- Up to 60% fuel reduction vs air‑fuel pre‑mix
Combustion Air, Blower & Emissions Specifications
- NOx Reduction Method
- Up to 80% vs air‑fuel pre‑mix
Electrical Specifications
- Maintenance Interval
- Very low/maintenance‑free design
Ignition, Flame & Supervision Specifications
- Cooling Requirements
- Clean dry air, nitrogen, or oxygen
Dimensions & Length Specifications
- Pipe Length Options
- 10 to 24 inch in 2-inch increments
Mechanical Design & Hardware Details
- Inlet Orientation
- Oxygen inlet at 90 deg to fuel inlet
Dimensions & Weight
- Block Dimensions
- 5 x 5 x 9 in
Connections & Interfaces
- Connection Type
- With or without NPT fittings
Material Specifications
- Burner Material
- 300‑series stainless steel gas tip and oxygen nozzle
- Block Material
- Fused Mullite, AZS
Burner/Flame‑Related Lengths
- Flame Length
- FH0517 - 3 to 7 in, FH0935 - 5 to 10 in, FH1350 - 7 to 12 in
Applications & Compatibility
- Applications
- The forehearth is the section of the glass furnace just after melting and just before forming.
Fuel, Gas & Media Specifications
- Fuel Type
- Natural Gas, Hydrogen blend (up to 20% H2/80% NG)
Combustion, Mixing & Fuel Dynamics
- Fuel Flow
- FH0517 - 5 to 17 SCFH, FH0935 - 9 to 35 SCFH, FH1350 - 13 to 50 SCFH
| Parameter | Published value / configuration |
|---|---|
| Models | FH0517, FH0935, FH1350 |
| Burner Type | Oxygen burner for forehearth applications |
| Fuel Efficiency Improvement | Up to 60% fuel reduction vs air‑fuel pre‑mix |
| NOx Reduction Method | Up to 80% vs air‑fuel pre‑mix |
| Maintenance Interval | Very low/maintenance‑free design |
| Cooling Requirements | Clean dry air, nitrogen, or oxygen |
| Pipe Length Options | 10 to 24 inch in 2-inch increments |
| Inlet Orientation | Oxygen inlet at 90 deg to fuel inlet |
| Block Dimensions | 5 x 5 x 9 in |
| Connection Type | With or without NPT fittings |
| Burner Material | 300‑series stainless steel gas tip and oxygen nozzle |
| Block Material | Fused Mullite, AZS |
| Flame Length | FH0517 - 3 to 7 in, FH0935 - 5 to 10 in, FH1350 - 7 to 12 in |
| Applications | The forehearth is the section of the glass furnace just after melting and just before forming. |
| Fuel Type | Natural Gas, Hydrogen blend (up to 20% H2/80% NG) |
| Fuel Flow | FH0517 - 5 to 17 SCFH, FH0935 - 9 to 35 SCFH, FH1350 - 13 to 50 SCFH |
Values retain manufacturer model qualifications. Review Honeywell specifications ↗
Part Number
Published part numbers
10 parts
| Part Number | Description | Enquiry |
|---|---|---|
| 10057031 | FLEXHOSE,.375 IN. X 24 IN. LG,.375 IN. 3 | Request quotation |
| 10057032 | FLEXHOSE,.25 IN. X 24 IN. LG,.25 IN. 37 | Request quotation |
| 18862 | SHT MTL,STRP,BAT,SZMK,CAB-4 | Request quotation |
| 18866 | SHT MTL,BRKT,SZMK,FCPS | Request quotation |
| 50151045-001 | DISCHARGE BLOCK, AZS | Request quotation |
| 50151046-001 | GASKET, BLOCK | Request quotation |
| 50153127-001 | DISCHARGE BLOCK, MULLITE | Request quotation |
| 50153759-002 | SISECAM FUEL TUBE | Request quotation |
| 50153761-002 | RETRO-FIT FH SISECAM FUEL NZL WLDMNT ASY | Request quotation |
| 50153762-001 | RETRO-FIT FH SISECAM FUEL NZL ASYREF | Request quotation |
Manufacturer sources
Last source check: 2026-11-02
Next Generation PrimeFire FH Product Image · Manufacturer ownership retained; republication licence not independently confirmed
Glass & Oxygen Burners Category Image · Manufacturer ownership retained; republication licence not independently confirmed
Next Generation PrimeFire FH Product Image 3 · Manufacturer ownership retained; republication licence not independently confirmed
Next Generation PrimeFire FH Product Image 1 · Manufacturer ownership retained; republication licence not independently confirmed
Next Generation PrimeFire FH Product Image 2 · Manufacturer ownership retained; republication licence not independently confirmed
ABID Automation LTD maintains this independent product reference. Honeywell owns its product names and trademarks. Current manufacturer documentation governs specification, availability and certification.
Your next project. A clear starting point.
Tell us about your facility and what you need to achieve.