CD Actuator Systems
Devronizer
Devronizer heats the moving paper web with steam to improve water removal during pressing and reduce later drying requirements.
Devronizer heats the moving paper web with steam to improve water removal during pressing and reduce later drying requirements. Each shower is designed for the appropriate wet-end location and machine arrangement, including table, couch, press or Yankee duties. Controlled heat transfer supports dewatering and moisture profiling, helping papermakers balance production rate, dryer energy and sheet conditions.
Features & Benefits
- Technology
- Wet-end steam shower
- Improves dewatering and reduces dryer demand
Applications
- Paper, board and tissue machines
Detailed capabilities
Product and configuration
Devronizer heats the moving paper web with steam to improve water removal during pressing and reduce later drying requirements. Each shower is designed for the appropriate wet-end location and machine arrangement, including table, couch, press or Yankee duties. Controlled heat transfer supports dewatering and moisture profiling, helping papermakers balance production rate, dryer energy and sheet conditions.
- Technology: Wet-end steam shower
Operation and integration
Devronizer adds steam heat at an application-specific wet-end location to improve press dewatering and cross-direction moisture profiling. Configurations serve table, couch, press and Yankee applications. Compact construction, XP10 actuators, conditioned steam and removable screen plates support integration and maintenance.
Application and selection
Greater water removal before drying can reduce dryer load or increase output on dryer-limited machines. Moisture profile, reel build, break recovery and sheet consolidation are related objectives. The assembly is customized for the machine, grade and available installation position.
Mechanical & Physical Properties
- Actuator Zone Width
- 50 mm
Environmental Conditions
- Retraction Air Pressure
- 415 kPa; 60 psi
- Actuator Air Pressure
- 40 to 210 kPa; 6 to 30 psi
Others
- Steam Pressure Rating
- Maximum: 103 kPa (15 psi); Normal: 14 to 69 kPa (2 to 10 psi)
- Mounting/Retraction
- 100 mm (4 in) Standard Retraction; Epoxy-Coated Mild Steel; Stainless Steel Optional
- Steam Temperature
- Minimum: 125 deg C (260 deg F); Normal: 125 to 135 deg C (260 to 280 deg F)
- Pneumatic Tubing
- Internal and External PTFE (Teflon®)
- Body Material
- 316L Stainless Steel
| Parameter | Published value / configuration |
|---|---|
| Actuator Zone Width | 50 mm |
| Retraction Air Pressure | 415 kPa; 60 psi |
| Actuator Air Pressure | 40 to 210 kPa; 6 to 30 psi |
| Steam Pressure Rating | Maximum: 103 kPa (15 psi); Normal: 14 to 69 kPa (2 to 10 psi) |
| Mounting/Retraction | 100 mm (4 in) Standard Retraction; Epoxy-Coated Mild Steel; Stainless Steel Optional |
| Steam Temperature | Minimum: 125 deg C (260 deg F); Normal: 125 to 135 deg C (260 to 280 deg F) |
| Pneumatic Tubing | Internal and External PTFE (Teflon®) |
| Body Material | 316L Stainless Steel |
Values retain manufacturer model qualifications. Review Honeywell specifications ↗
Resources
Resources linked from the manufacturer’s page. Confirm the document revision and applicable model before installation or ordering.
Honeywell resource listing ↗Manufacturer sources
Last source check: 2026-11-02
Devronizer Product Image · Manufacturer ownership retained; republication licence not independently confirmed
Devronizer Product Image · Manufacturer ownership retained; republication licence not independently confirmed
Devronizer Product Image · Manufacturer ownership retained; republication licence not independently confirmed
ABID Automation LTD maintains this independent product reference. Honeywell owns its product names and trademarks. Current manufacturer documentation governs specification, availability and certification.
Your next project. A clear starting point.
Tell us about your facility and what you need to achieve.