CD Actuator Systems
CalCoil PRO
Calcoil Pro uses induction heating to adjust calender-roll temperature for cross-direction caliper control and finishing.
Calcoil Pro uses induction heating to adjust calender-roll temperature for cross-direction caliper control and finishing. Individually controlled coils sit close to the roll without mechanical contact and are contoured for the installation. The system combines these actuators with power modules and control software, supporting localized heating and sheet-profile adjustment without adding a drive load to rotate the roll.
Models: 9760-00, 9760-01, 9760-10, 9760-11
Features & Benefits
- Technology
- Non-contact induction heating
- Actuation
- Individually controlled contoured workcoils
- Supports efficient localized roll heating
Applications
- Paper calender caliper control and finishing
Detailed capabilities
Product and configuration
Calcoil Pro uses induction heating to adjust calender-roll temperature for cross-direction caliper control and finishing. Individually controlled coils sit close to the roll without mechanical contact and are contoured for the installation. The system combines these actuators with power modules and control software, supporting localized heating and sheet-profile adjustment without adding a drive load to rotate the roll.
- Technology: Non-contact induction heating
- Actuation: Individually controlled contoured workcoils
Operation and integration
Calcoil PRO uses alternating-current induction to heat a calender roll without contacting it or adding roll drive load. Contoured, epoxy-protected workcoils form independently controlled zones; two zones share a shoe. The published working gap is 3–7 mm for effective magnetic coupling.
Application and selection
Localized roll heating changes nip loading for cross-direction caliper correction, while average power influences gloss or smoothness in the machine direction. The actuator system supports finishing quality, runnability and lower rejects, with coil contour and installation matched to the roll.
Environmental Conditions
- Power Module Cooling Air Supply Temperature
- 20 to 40 deg C; 68 to 104 deg F
Electrical Specifications
- Power Module Cooling Air Flow
- 1.2 to 1.4 Nm3/min; 42 to 48 SCFM
Mechanical & Physical Properties
- Actuator Zone Width
- 2.95 in; 75 mm
Others
- Models
- 9760-00; 9760-01; 9760-10; 9760-11
- Power Module Cooling Air Supply Inlet Pressure
- 50 to 90 mm H2O
- Maximum Output Power
- 4500 W; 4500 to 6000 W
- Energy Efficiency
- 0.94
- Construction Type
- High Temperature Epoxy; Water Cooled
- Input Frequency
- 50 or 60 Hz hertz
- Input Voltage
- 3 phase 380~456 VAC voltage alternating current
- Input Power
- 5 kVA voltage direct current; 5 to 6.7 kVA voltage direct current
- Standards
- CSA; UL
| Parameter | Published value / configuration |
|---|---|
| Power Module Cooling Air Supply Temperature | 20 to 40 deg C; 68 to 104 deg F |
| Power Module Cooling Air Flow | 1.2 to 1.4 Nm3/min; 42 to 48 SCFM |
| Actuator Zone Width | 2.95 in; 75 mm |
| Models | 9760-00; 9760-01; 9760-10; 9760-11 |
| Power Module Cooling Air Supply Inlet Pressure | 50 to 90 mm H2O |
| Maximum Output Power | 4500 W; 4500 to 6000 W |
| Energy Efficiency | 0.94 |
| Construction Type | High Temperature Epoxy; Water Cooled |
| Input Frequency | 50 or 60 Hz hertz |
| Input Voltage | 3 phase 380~456 VAC voltage alternating current |
| Input Power | 5 kVA voltage direct current; 5 to 6.7 kVA voltage direct current |
| Standards | CSA; UL |
Values retain manufacturer model qualifications. Review Honeywell specifications ↗
Resources
Resources linked from the manufacturer’s page. Confirm the document revision and applicable model before installation or ordering.
Honeywell resource listing ↗Part Number
Published model / variant identifiers. A full ordering code requires the manufacturer configuration.
Manufacturer sources
Last source check: 2026-11-02
CalCoil PRO Product Image · Manufacturer ownership retained; republication licence not independently confirmed
ABID Automation LTD maintains this independent product reference. Honeywell owns its product names and trademarks. Current manufacturer documentation governs specification, availability and certification.
Your next project. A clear starting point.
Tell us about your facility and what you need to achieve.