Fixed Gauging
CT801 Electropneumatic Level Transmitters
CT801 electropneumatic transmitters determine tank level from the pressure of bubbling air or neutral gas.
CT801 electropneumatic transmitters determine tank level from the pressure of bubbling air or neutral gas. Instruments can operate independently with a 4–20 mA loop or in a TN3801 cabinet holding up to 24 devices. The corrosion-resistant construction and low gas consumption suit ballast and service tanks, with cabinet communication available through duplicated serial links.
Models: CT801-LB/S, CT801-SI, CT801A, CT801-TA
Features & Benefits
- Configurations
- Standalone or TN3801 cabinet
- Cabinet capacity
- Up to 24 devices
- Supports compact multi-tank installations
Applications
- Marine ballast and service-tank level measurement
Detailed capabilities
Product and configuration
CT801 electropneumatic transmitters determine tank level from the pressure of bubbling air or neutral gas. Instruments can operate independently with a 4–20 mA loop or in a TN3801 cabinet holding up to 24 devices. The corrosion-resistant construction and low gas consumption suit ballast and service tanks, with cabinet communication available through duplicated serial links.
- Configurations: Standalone or TN3801 cabinet
- Cabinet capacity: Up to 24 devices
Operation and integration
CT801 infers level from the pressure in an air or neutral-gas line bubbling at the tank bottom. An electronic pressure conditioner converts that pressure into the output signal. A standalone instrument is intrinsically safe and loop-powered; a TN3801 cabinet supplies a compact multi-instrument arrangement with two RS422/RS485 connections. Low gas consumption, self-protection and modular installation support shipboard maintenance.
Application and selection
The system measures liquids in ballast and service tanks without placing the main transmitter directly at the tank bottom. Honeywell describes durable, corrosion-resistant operation with limited calibration and maintenance effort. The cabinet holds up to twenty-four instruments; its mains power and serial interfaces should not be attributed to the standalone loop-powered version.
Processing & Performance Metrics
- Accuracy
- ±0.3% full scale at 20 deg C
Standards & Certifications
- Protection Class
- IP66, IP67
- Intrinsic Safety Approvals
- IECEx, ATEX., II 1 G D, Ex ia IIC T6 Ga, Ex ia IIIC T70 deg C Da
Electrical Specifications
- Power Supply
- 12 to 28VDC
- Output Signal
- 4 to 20 mA
Environmental Conditions
- Operating Temperature Range
- '-20 to +70 deg C/-35 to +70 deg C/-40 to +70 deg C
- Air Supply Quality
- 4 to 10 Bar, (3) Quality, Particle size: 5 microns, PressureDewpoint:-20 deg C, Oil content: 1mg/m3
Overview
- Models
- CT801-LB/S, CT801-SI, CT801A, CT801-TA
I/O Capabilities
- Explosion Proof Approval
- ATEX., II 2 G, Ex d IIC T6 Gb (CT801A)
Applications & Compatibility
- Applications
- The CT801 family of electropneumatic level transmitters provides high‑reliability tank level measurement with an exceptionally low cost of ownership for marine industry.
Others
- Pressure Range
- 0 to 4000 mBar
| Parameter | Published value / configuration |
|---|---|
| Accuracy | ±0.3% full scale at 20 deg C |
| Protection Class | IP66, IP67 |
| Intrinsic Safety Approvals | IECEx, ATEX., II 1 G D, Ex ia IIC T6 Ga, Ex ia IIIC T70 deg C Da |
| Power Supply | 12 to 28VDC |
| Output Signal | 4 to 20 mA |
| Operating Temperature Range | '-20 to +70 deg C/-35 to +70 deg C/-40 to +70 deg C |
| Air Supply Quality | 4 to 10 Bar, (3) Quality, Particle size: 5 microns, PressureDewpoint:-20 deg C, Oil content: 1mg/m3 |
| Models | CT801-LB/S, CT801-SI, CT801A, CT801-TA |
| Explosion Proof Approval | ATEX., II 2 G, Ex d IIC T6 Gb (CT801A) |
| Applications | The CT801 family of electropneumatic level transmitters provides high‑reliability tank level measurement with an exceptionally low cost of ownership for marine industry. |
| Pressure Range | 0 to 4000 mBar |
Values retain manufacturer model qualifications. Review Honeywell specifications ↗
Resources
Resources linked from the manufacturer’s page. Confirm the document revision and applicable model before installation or ordering.
Honeywell resource listing ↗Part Number
Published model / variant identifiers. A full ordering code requires the manufacturer configuration.
Published part numbers
10 parts
| Part Number | Description | Enquiry |
|---|---|---|
| 219449 | POT DRAFT | Request quotation |
| 220042-HMS | CT180 PNEU.LEVEL INDICATOR 0-390 mbar | Request quotation |
| 220043-HMS | CT180 PNEU.LEVEL INDICAT. 0-390/1000mbar | Request quotation |
| 220045-HMS | CT180 PNEU.LEVEL INDICAT.0-2000/3000mbar | Request quotation |
| 220143 | CT 080 LEVEL INDICATOR | Request quotation |
| 22756-HMS | POT DRAUGHT PN16 DN40-DN50 P/N 22756 | Request quotation |
| 24761 | SAFETY CHAMBER or SAFETY POT | Request quotation |
| 24806 | SPCG PN16 DN40 L=SVT CDE MANOMETER | Request quotation |
| 28678 | FITTING LEGRIS 1805-10-13 (R1/4 Dia=10) | Request quotation |
| 29238-HMS | TEST UNIT FOR PNEUMATIC TRANSMITTER | Request quotation |
Manufacturer sources
Last source check: 2026-11-02
CT801 Electropneumatic Level Transmitters image · Manufacturer ownership retained; republication licence not independently confirmed
CT801 Electropneumatic Level Transmitters image · Manufacturer ownership retained; republication licence not independently confirmed
CT801 Electropneumatic Level Transmitters image · Manufacturer ownership retained; republication licence not independently confirmed
CT801 Electropneumatic Level Transmitters image · Manufacturer ownership retained; republication licence not independently confirmed
ABID Automation LTD maintains this independent product reference. Honeywell owns its product names and trademarks. Current manufacturer documentation governs specification, availability and certification.
Your next project. A clear starting point.
Tell us about your facility and what you need to achieve.