Fire & Life Safety · Building Systems · Industrial Automation [email protected] +880 1347 561 256
Honeywell Process Measurement & Control

Fixed Gauging

CT801 Electropneumatic Level Transmitters

CT801 electropneumatic transmitters determine tank level from the pressure of bubbling air or neutral gas.

CT801 electropneumatic transmitters determine tank level from the pressure of bubbling air or neutral gas. Instruments can operate independently with a 4–20 mA loop or in a TN3801 cabinet holding up to 24 devices. The corrosion-resistant construction and low gas consumption suit ballast and service tanks, with cabinet communication available through duplicated serial links.

Models: CT801-LB/S, CT801-SI, CT801A, CT801-TA

Features & Benefits

Configurations
Standalone or TN3801 cabinet
Cabinet capacity
Up to 24 devices
  • Supports compact multi-tank installations

Applications

  • Marine ballast and service-tank level measurement

Detailed capabilities

Product and configuration

CT801 electropneumatic transmitters determine tank level from the pressure of bubbling air or neutral gas. Instruments can operate independently with a 4–20 mA loop or in a TN3801 cabinet holding up to 24 devices. The corrosion-resistant construction and low gas consumption suit ballast and service tanks, with cabinet communication available through duplicated serial links.

  • Configurations: Standalone or TN3801 cabinet
  • Cabinet capacity: Up to 24 devices

Manufacturer reference ↗

Operation and integration

CT801 infers level from the pressure in an air or neutral-gas line bubbling at the tank bottom. An electronic pressure conditioner converts that pressure into the output signal. A standalone instrument is intrinsically safe and loop-powered; a TN3801 cabinet supplies a compact multi-instrument arrangement with two RS422/RS485 connections. Low gas consumption, self-protection and modular installation support shipboard maintenance.

Manufacturer reference ↗

Application and selection

The system measures liquids in ballast and service tanks without placing the main transmitter directly at the tank bottom. Honeywell describes durable, corrosion-resistant operation with limited calibration and maintenance effort. The cabinet holds up to twenty-four instruments; its mains power and serial interfaces should not be attributed to the standalone loop-powered version.

Manufacturer reference ↗

Case studies & further resources

Manufacturer Document

SYSTEM 3400 (With 34000 Devices) Analogue Addressable Fire Detection and Alarm System User Manual

View resource ↗
Manufacturer Document

SYSTEM 3400 (With 34000 Devices) Analogue Addressable Fire Detection and Alarm System User Manual

View resource ↗
Manufacturer Document

SYSTEM 3400 (With 34000 Devices) Analogue Addressable Fire Detection and Alarm System Installation Manual

View resource ↗
Manufacturer Document

CT801-LB/S Electropneumatic Level Transmitter - Protected Areas - Data Sheet - English

View resource ↗
Manufacturer Document

CT801-SI Electropneumatic Level Transmitter - Deck Installation - Data Sheet - English

View resource ↗
Manufacturer Document

CT801A Electropneumatic Level Transmitter - Deck Installation - Data Sheet - English

View resource ↗
Manufacturer Document

CT801-TA Electropneumatic Level Transmitter - Deck Installation - Data Sheet - English

View resource ↗

Specifications

Processing & Performance Metrics

Accuracy
±0.3% full scale at 20 deg C

Standards & Certifications

Protection Class
IP66, IP67
Intrinsic Safety Approvals
IECEx, ATEX., II 1 G D, Ex ia IIC T6 Ga, Ex ia IIIC T70 deg C Da

Electrical Specifications

Power Supply
12 to 28VDC
Output Signal
4 to 20 mA

Environmental Conditions

Operating Temperature Range
'-20 to +70 deg C/-35 to +70 deg C/-40 to +70 deg C
Air Supply Quality
4 to 10 Bar, (3) Quality, Particle size: 5 microns, PressureDewpoint:-20 deg C, Oil content: 1mg/m3

Overview

Models
CT801-LB/S, CT801-SI, CT801A, CT801-TA

I/O Capabilities

Explosion Proof Approval
ATEX., II 2 G, Ex d IIC T6 Gb (CT801A)

Applications & Compatibility

Applications
The CT801 family of electropneumatic level transmitters provides high‑reliability tank level measurement with an exceptionally low cost of ownership for marine industry.

Others

Pressure Range
0 to 4000 mBar
CT801 Electropneumatic Level Transmitters — manufacturer page values
ParameterPublished value / configuration
Accuracy±0.3% full scale at 20 deg C
Protection ClassIP66, IP67
Intrinsic Safety ApprovalsIECEx, ATEX., II 1 G D, Ex ia IIC T6 Ga, Ex ia IIIC T70 deg C Da
Power Supply12 to 28VDC
Output Signal4 to 20 mA
Operating Temperature Range'-20 to +70 deg C/-35 to +70 deg C/-40 to +70 deg C
Air Supply Quality4 to 10 Bar, (3) Quality, Particle size: 5 microns, PressureDewpoint:-20 deg C, Oil content: 1mg/m3
ModelsCT801-LB/S, CT801-SI, CT801A, CT801-TA
Explosion Proof ApprovalATEX., II 2 G, Ex d IIC T6 Gb (CT801A)
ApplicationsThe CT801 family of electropneumatic level transmitters provides high‑reliability tank level measurement with an exceptionally low cost of ownership for marine industry.
Pressure Range0 to 4000 mBar

Values retain manufacturer model qualifications. Review Honeywell specifications ↗

Resources

Filter documents by type

Resources linked from the manufacturer’s page. Confirm the document revision and applicable model before installation or ordering.

Honeywell resource listing ↗

Part Number

Published model / variant identifiers. A full ordering code requires the manufacturer configuration.

Published part numbers

10 parts

Part NumberDescriptionEnquiry
219449POT DRAFTRequest quotation
220042-HMSCT180 PNEU.LEVEL INDICATOR 0-390 mbarRequest quotation
220043-HMSCT180 PNEU.LEVEL INDICAT. 0-390/1000mbarRequest quotation
220045-HMSCT180 PNEU.LEVEL INDICAT.0-2000/3000mbarRequest quotation
220143CT 080 LEVEL INDICATORRequest quotation
22756-HMSPOT DRAUGHT PN16 DN40-DN50 P/N 22756Request quotation
24761SAFETY CHAMBER or SAFETY POTRequest quotation
24806SPCG PN16 DN40 L=SVT CDE MANOMETERRequest quotation
28678FITTING LEGRIS 1805-10-13 (R1/4 Dia=10)Request quotation
29238-HMSTEST UNIT FOR PNEUMATIC TRANSMITTERRequest quotation
Manufacturer sources

https://process.honeywell.com/us/en/products/marine/fixed-gauging/ct801-electropneumatic-level-transmitters

Last source check: 2026-11-02

CT801 Electropneumatic Level Transmitters image · Manufacturer ownership retained; republication licence not independently confirmed

CT801 Electropneumatic Level Transmitters image · Manufacturer ownership retained; republication licence not independently confirmed

CT801 Electropneumatic Level Transmitters image · Manufacturer ownership retained; republication licence not independently confirmed

CT801 Electropneumatic Level Transmitters image · Manufacturer ownership retained; republication licence not independently confirmed

ABID Automation LTD maintains this independent product reference. Honeywell owns its product names and trademarks. Current manufacturer documentation governs specification, availability and certification.

Your next project. A clear starting point.

Tell us about your facility and what you need to achieve.