Ultrasonic Meters
Q.Sonic®-max Ultrasonic Gas Meter
Q.Sonic-max measures gas flow through eight ultrasonic paths combining direct and reflective arrangements.
Q.Sonic-max measures gas flow through eight ultrasonic paths combining direct and reflective arrangements. The geometry addresses installation effects arising from disturbed upstream flow profiles. The manufacturer identifies custody transfer in large natural-gas pipelines and publishes compliance targets including ISO 17089 accuracy class 0.5, with actual suitability governed by the selected meter configuration.
Features & Benefits
- Paths
- 8, combining direct and reflected paths
- Published accuracy class
- ISO 17089 class 0.5
- Path design reduces sensitivity to installation effects
Applications
- Natural gas pipeline custody transfer
Detailed capabilities
Q.Sonic®-max Ultrasonic Gas Meter — purpose and deployment
Q.Sonic-max measures gas flow through eight ultrasonic paths combining direct and reflective arrangements. The geometry addresses installation effects arising from disturbed upstream flow profiles. The manufacturer identifies custody transfer in large natural-gas pipelines and publishes compliance targets including ISO 17089 accuracy class 0.5, with actual suitability governed by the selected meter configuration.
Eight acoustic paths and profile diagnostics
Q.Sonic-max combines two double-reflection swirl paths with six direct paths. The reflective measurements detect profile changes and can reveal swirl, fouling or liquid presence, while the direct paths improve robustness for demanding mixtures such as CO2-rich gas. This geometry addresses installation effects from upstream piping while supporting low uncertainty.
Measurement references and cybersecurity
The source identifies OIML R137, MID, AGA9 and ISO17089 class0.5 in its measurement discussion. Its updated cybersecurity package includes TLS, encrypted parameterization information and separate protection of sensitive data, with secure-development standard references. These capabilities supplement the acoustic measurement and diagnostic functions rather than changing the number or type of paths.
Environmental Conditions
- Ambient Temperature Range
- Extended: -40 to +55 deg C; MID: -40 to +55 deg C; Standard: -40 to +60 deg C
- Process Temperature Range
- Extended: -40 to +80 deg C; MID: -40 to +55 deg C; Standard: -40 to +60 deg C
- Pressure Ratings
- ASME 300 - 600 (others on request)
Measurement & Sensor Related (Measurement Capabilities)
- Typical Uncertainty
- 0.1% (Linearization); 0.2% (High-Pressure Calibration); 0.5% (Zero Flow Calibration)
- Repeatability
- ≤ 0.05%
Processing & Performance Metrics
- Software
- EnSuite PC Software for Configuration, Diagnostics, Healthcare
Mechanical & Physical Properties
- Sizes
- 4 to 24 in (DN 100 to DN 600); Up to 36 in on request
Electrical Specifications
- Power Supply
- 24 VDC (18 to 30 V), 10 to 20 W
I/O Capabilities
- Path Configuration
- 8-Path Configuration (6 Direct + 2 Swirl Reflection Paths)
Standards & Certifications
- Metrological Approvals
- MID, OIML R137 Class 0.5, ISO 17089 Class 0.5, AGA9
- Ingress Protection
- IP66 (NEMA 4X)
- Hazardous Location Approvals
- ATEX, IECEx, FM Approvals
Communication Interfaces
- Interfaces
- (2) Serial (RS232/485), (1) Ethernet, (2) Freq Outputs, (2) Digital, (2) Analog (4 to 20 mA), (1) USB
Software & Interface
- Display
- 4.3 in Graphical Color Display, 7 Capacitive Soft Keys, LEDs
Communication & Protocols
- Communication Protocols
- Modbus (ASCII, RTU, TCP/IP), UNIFORM, MMS, Web Server, TLS Encryption
Material Specifications
- Body Material
- Stainless is an ETO -> LTCS only
Applications & Compatibility
- Applications
- Custody transfer and non-custody transfer of natural gas and other gases
| Parameter | Published value / configuration |
|---|---|
| Ambient Temperature Range | Extended: -40 to +55 deg C; MID: -40 to +55 deg C; Standard: -40 to +60 deg C |
| Process Temperature Range | Extended: -40 to +80 deg C; MID: -40 to +55 deg C; Standard: -40 to +60 deg C |
| Pressure Ratings | ASME 300 - 600 (others on request) |
| Typical Uncertainty | 0.1% (Linearization); 0.2% (High-Pressure Calibration); 0.5% (Zero Flow Calibration) |
| Repeatability | ≤ 0.05% |
| Software | EnSuite PC Software for Configuration, Diagnostics, Healthcare |
| Sizes | 4 to 24 in (DN 100 to DN 600); Up to 36 in on request |
| Power Supply | 24 VDC (18 to 30 V), 10 to 20 W |
| Path Configuration | 8-Path Configuration (6 Direct + 2 Swirl Reflection Paths) |
| Metrological Approvals | MID, OIML R137 Class 0.5, ISO 17089 Class 0.5, AGA9 |
| Ingress Protection | IP66 (NEMA 4X) |
| Hazardous Location Approvals | ATEX, IECEx, FM Approvals |
| Interfaces | (2) Serial (RS232/485), (1) Ethernet, (2) Freq Outputs, (2) Digital, (2) Analog (4 to 20 mA), (1) USB |
| Display | 4.3 in Graphical Color Display, 7 Capacitive Soft Keys, LEDs |
| Communication Protocols | Modbus (ASCII, RTU, TCP/IP), UNIFORM, MMS, Web Server, TLS Encryption |
| Body Material | Stainless is an ETO -> LTCS only |
| Applications | Custody transfer and non-custody transfer of natural gas and other gases |
Values retain manufacturer model qualifications. Review Honeywell specifications ↗
Part Number
Published part numbers
2 parts
| Part Number | Description | Enquiry |
|---|---|---|
| VMU185A1017 | VENTURI 185 KW (WOLF) | Request quotation |
| VMU500A1041 | VENTURI 500 KW VIESSMANN | Request quotation |
Manufacturer sources
Last source check: 2026-11-02
Q.Sonic-max Product Image · Manufacturer ownership retained; republication licence not independently confirmed
ABID Automation LTD maintains this independent product reference. Honeywell owns its product names and trademarks. Current manufacturer documentation governs specification, availability and certification.
Your next project. A clear starting point.
Tell us about your facility and what you need to achieve.