HON 901 heats pilot gas using a vortex tube and the Ranque-Hilsch effect, without an additional energy supply.

HON 901 heats pilot gas using a vortex tube and the Ranque-Hilsch effect, without an additional energy supply. There are no moving parts inside the tube, and the arrangement uses little tubing. An optional pneumatic control unit is identified for stations that can reach zero gas consumption; operation must meet the published inlet-to-outlet pressure relationship.

Models: HON 901

Features & Benefits

Maximum admissible pressure
100 bar
Principle
Pneumatic vortex tube
  • No additional heating energy supply and no internal moving parts

Applications

  • Pilot gas preheating

Detailed capabilities

HON 901 — operating design

HON 901 heats pilot gas using a vortex tube and the Ranque-Hilsch effect, without an additional energy supply. There are no moving parts inside the tube, and the arrangement uses little tubing. An optional pneumatic control unit is identified for stations that can reach zero gas consumption; operation must meet the published inlet-to-outlet pressure relationship.

Manufacturer reference ↗

Vortex heating and installation constraints

HON 901 uses the Ranque-Hilsch effect, so the vortex tube has no moving internal parts and does not need an additional heating supply. The optional pneumatic controller is associated with stations that can reach zero consumption. Its operating relationship requires inlet pressure to be at least twice outlet pressure plus five bar; the pressure relationship is essential to selection, not an unconditional heating promise.

Manufacturer reference ↗

Published configuration and technical facts

The manufacturer lists these values for HON 901. Version, size and option qualifications remain attached to each fact.

  • Maximum Housing Temperature Range: Approx. 60 deg C at Room Temperature (approx. 20 deg C)
  • Maximum Operating Pressure: Up to 100 bar kilopascal
  • Maximum Admissible Pressure: 100 bar
  • Explosion Protection: They are not subject to ATEX 95 (94/9/EC). All electrical components used with this device fulfill the ATEX requirements
  • Connection Type: Pipe Connections according to DIN EN ISO 8434-1 (DIN 2353), PN 100, for pipe sizes 10 mm and 12 mm

Manufacturer reference ↗

Specifications

Environmental Conditions

Maximum Housing Temperature Range
Approx. 60 deg C at Room Temperature (approx. 20 deg C)
Maximum Operating Pressure
Up to 100 bar kilopascal

Processing & Performance Metrics

Maximum Admissible Pressure
100 bar

Standards & Certifications

Explosion Protection
They are not subject to ATEX 95 (94/9/EC). All electrical components used with this device fulfill the ATEX requirements

Technical Specifications

Connection Type
Pipe Connections according to DIN EN ISO 8434-1 (DIN 2353), PN 100, for pipe sizes 10 mm and 12 mm
HON 901 — manufacturer page values
ParameterPublished value / configuration
Maximum Housing Temperature RangeApprox. 60 deg C at Room Temperature (approx. 20 deg C)
Maximum Operating PressureUp to 100 bar kilopascal
Maximum Admissible Pressure100 bar
Explosion ProtectionThey are not subject to ATEX 95 (94/9/EC). All electrical components used with this device fulfill the ATEX requirements
Connection TypePipe Connections according to DIN EN ISO 8434-1 (DIN 2353), PN 100, for pipe sizes 10 mm and 12 mm

Values retain manufacturer model qualifications. Review Honeywell specifications ↗

Part Number

Published model / variant identifiers. A full ordering code requires the manufacturer configuration.

Manufacturer sources

https://process.honeywell.com/us/en/products/gas/regulators-and-safety-accessories/pilot-heater/hon-901

Last source check: 2026-11-02

HON 901 Image · Manufacturer ownership retained; republication licence not independently confirmed

ABID Automation LTD maintains this independent product reference. Honeywell owns its product names and trademarks. Current manufacturer documentation governs specification, availability and certification.

Your next project. A clear starting point.

Tell us about your facility and what you need to achieve.

CallSend enquiry