Pilot Heater
HON 900
HON 900 electrically preheats control gas for equipment such as pneumatic pilots.
HON 900 electrically preheats control gas for equipment such as pneumatic pilots. Gas passes through a steel tube cast into an aluminum block warmed by a self-regulating heater. The unit can mount in any position and is published for non-aggressive gases, with the stated electrical supply and explosion-protection arrangement defining its installation requirements.
Models: HON 900
Features & Benefits
- Maximum admissible pressure
- 200 bar
- Supply
- 230 V / 50 Hz
- Consumption
- 150 W
- Any-position mounting
Applications
- Control-gas preheating for pneumatic pilots
Processing & Performance Metrics
- Maximum Admissible Pressure
- 200 bar
Environmental Conditions
- Maximum Operating Pressure
- 100 bar (Standard), 200 bar (Special Version) kilopascal
- Maximum Temperature Range
- Approx. 78 deg C (Aluminum Block at Room Temperature, 21 deg C)
- Operating Voltage
- 230 VAC/50 Hz
Standards & Certifications
- Explosion Protection
- II 2 G EEx e II or de IIC T6 ... T1
- Degree of Protection
- IP54 (IP65 optional)
- Approvals
- PTB 03 ATEX 1075 X, EC prototype test PTB 03 ATEX 1075 X, Ex II 2 G EEx e II or de IIC T6 ... T1
Electrical Specifications
- Power Consumption
- 150 W
Technical Specifications
- Gas Connections
- Screwed Pipe Connection (DIN 2353), Pipe Outer Diameter - 10 mm
Applications & Compatibility
- Applications
- Pre-heating gas to pneumatic pilots; Suitable for natural gas and non-aggressive gases
Material Specifications
- Materials
- Steel pipe cast into aluminum block
| Parameter | Published value / configuration |
|---|---|
| Maximum Admissible Pressure | 200 bar |
| Maximum Operating Pressure | 100 bar (Standard), 200 bar (Special Version) kilopascal |
| Maximum Temperature Range | Approx. 78 deg C (Aluminum Block at Room Temperature, 21 deg C) |
| Operating Voltage | 230 VAC/50 Hz |
| Explosion Protection | II 2 G EEx e II or de IIC T6 ... T1 |
| Degree of Protection | IP54 (IP65 optional) |
| Approvals | PTB 03 ATEX 1075 X, EC prototype test PTB 03 ATEX 1075 X, Ex II 2 G EEx e II or de IIC T6 ... T1 |
| Power Consumption | 150 W |
| Gas Connections | Screwed Pipe Connection (DIN 2353), Pipe Outer Diameter - 10 mm |
| Applications | Pre-heating gas to pneumatic pilots; Suitable for natural gas and non-aggressive gases |
| Materials | Steel pipe cast into aluminum block |
Values retain manufacturer model qualifications. Review Honeywell specifications ↗
Resources
Resources linked from the manufacturer’s page. Confirm the document revision and applicable model before installation or ordering.
Honeywell resource listing ↗Part Number
Published model / variant identifiers. A full ordering code requires the manufacturer configuration.
Published part numbers
6 parts
| Part Number | Description | Enquiry |
|---|---|---|
| HON121 | SERIES 121 IN-LINE TYPE FILTER | Request quotation |
| HON122 | SERIES 122 ANGLE TYPE FILTER | Request quotation |
| HON214 | Pressure Reducing Valve HON 214 | Request quotation |
| HON580 | SERIES 580 WAFERCHEK NON-RETURN VALVE | Request quotation |
| HON585 | SERIES 585 STREAMCHEK NON-RETURN VALVE | Request quotation |
| HON590 | SERIES 590 ROLLCHEK NON-RETURN VALVE | Request quotation |
Manufacturer sources
Last source check: 2026-11-02
HON 900 Image · Manufacturer ownership retained; republication licence not independently confirmed
ABID Automation LTD maintains this independent product reference. Honeywell owns its product names and trademarks. Current manufacturer documentation governs specification, availability and certification.
Your next project. A clear starting point.
Tell us about your facility and what you need to achieve.