Volume Converters
TCI250 Temperature Compensating Index
TCI250 applies temperature compensation directly at a rotary gas meter, with redundant volume sensing and AMR-ready outputs.
TCI250 applies temperature compensation directly at a rotary gas meter, with redundant volume sensing and AMR-ready outputs. MasterLink supports setup, while optional CloudLink 5G communication enables automated reporting. The manufacturer lists extended-life battery choices and remote firmware updating, but explicitly describes hazardous-location and metrological approvals as pending or in progress.
Models: TCI250 Temperature Compensating Index
Features & Benefits
- Mounting
- Integrated rotary mounting
- Remote update
- Firmware over the air
- Configuration
- MasterLink
- Approval status
- Hazardous-location and metrological approvals pending/in progress
- Supports automated data collection and fewer site visits
Applications
- Gas billing, custody transfer and commercial or industrial metering
Detailed capabilities
TCI250 Temperature Compensating Index — product role
TCI250 applies temperature compensation directly at a rotary gas meter, with redundant volume sensing and AMR-ready outputs. MasterLink supports setup, while optional CloudLink 5G communication enables automated reporting. The manufacturer lists extended-life battery choices and remote firmware updating, but explicitly describes hazardous-location and metrological approvals as pending or in progress.
Temperature correction and direct mounting
TCI250 uses measured temperature and redundant volume sensing to compensate rotary-meter readings. The compact direct-mount design supports standardized deployment across different meter fleets. Its intended work includes distribution billing, custody transfer and commercial or industrial stations, where accurate temperature correction and low-complexity installation are important.
Connected data and security
AMR support includes the named Itron, Aclara and Sensus systems, with optional CloudLink 5G communication for automated transfer. The source discusses TLS and secure-development practices alongside remote visibility and reduced visits. These functions supplement the temperature index; they do not make it a pressure-and-temperature corrector.
Pending approvals
The published CSA/IECEx hazardous-location approvals, Division and Zone ratings, and metrological approvals are marked pending. That status must remain explicit when the product is presented for custody-transfer or hazardous-area projects, rather than treating the stated intended applications as evidence of completed certification.
Applications & Compatibility
- Compatible Meter Types
- Compatible Meter Types; Dresser LMMA and B3; Romet RM and RMT
- Applications
- Accurate gas volume measurement with temperature compensation; Ideal replacement for mechanical TC indexes and Mercury TCI; Supports AMR (Automatic Meter Reading) connections
- Mounting
- Integrated Rotary mount for leading brand rotary gas meters
Processing & Performance Metrics
- Temperature Accuracy
- Maximum error at reference conditions: ±0.1% of reading
- Accuracy
- - Temperature: ±0.1% of reading; Including linearity, repeatability, and hysteresis; Maximum error over the full temperature range -40°F to 149°F (-40°C to 65°C)
Functional & Control Features
- Remote Upgrade
- via Firmware-over-the-air (FOTA)
- Audit Trail
- Single, configurable and flexible audit trail with up to 10 items w/ configurable interval: 1,5,10,15,30 minutes, hourly, daily, monthly, Year plus capacity hourly logging
Environmental Conditions
- Ambient Temperature Effects
- -40°F to 149°F (-40°C to 65°C)
- Relative Humidity
- 0 to 95% (Non-condensing)
Electrical Specifications
- External Power Supply
- No
- Power Supply
- Battery powered
- Battery Life
- Alkaline receptacle: up to 5 years; Lithium batteries: up to 15 years
- Battery
- Alkaline, Lithium
I/O Capabilities
- Inputs
- Redundant high frequency Wiegand sensor input
- Inputs/Outputs/Interfaces
- RS232 local configuration port plus RS232/485 serial interface
- Temperature Sensors
- RTD Temperature Sensor
- Outputs
- 4 Digital outputs (volume pulse + alarm), AMR-Ready and compatible with Itron, Aclara & Sensus AMR Devices
Software & Interface
- Configuration Software
- MasterLink
- Display
- Multi-line Display with Single push button operation
Communication & Protocols
- Communication Protocols
- Mercury Instruments
- Communication
- Optional class I Div. 1 cellular radio modem CloudLink 5G
Standards & Certifications
- Metrological Approvals
- Measurement Canada (pending)
- Explosion Protection
- Ambient Temperature: -40 °C to +65 °C; CSA IECx (in progress):; Class I, Zone 2 AEx ic IIB Gc; IECEx: Ex ia IIB + H2 T4 Ga; IECEx: Ex ic IIB + H2 T4 Gc; Intrinsically Safe, Class I, Division 1 Groups B, C, D T4; Non Incendive Field Wiring, Class I, Division 2 Groups B, C, D T4; Non Incendive, Class I, Division 2 Groups B, C, D T4
- Protection Class
- NEMAX 4
| Parameter | Published value / configuration |
|---|---|
| Compatible Meter Types | Compatible Meter Types; Dresser LMMA and B3; Romet RM and RMT |
| Applications | Accurate gas volume measurement with temperature compensation; Ideal replacement for mechanical TC indexes and Mercury TCI; Supports AMR (Automatic Meter Reading) connections |
| Mounting | Integrated Rotary mount for leading brand rotary gas meters |
| Temperature Accuracy | Maximum error at reference conditions: ±0.1% of reading |
| Accuracy | - Temperature: ±0.1% of reading; Including linearity, repeatability, and hysteresis; Maximum error over the full temperature range -40°F to 149°F (-40°C to 65°C) |
| Remote Upgrade | via Firmware-over-the-air (FOTA) |
| Audit Trail | Single, configurable and flexible audit trail with up to 10 items w/ configurable interval: 1,5,10,15,30 minutes, hourly, daily, monthly, Year plus capacity hourly logging |
| Ambient Temperature Effects | -40°F to 149°F (-40°C to 65°C) |
| Relative Humidity | 0 to 95% (Non-condensing) |
| External Power Supply | No |
| Power Supply | Battery powered |
| Battery Life | Alkaline receptacle: up to 5 years; Lithium batteries: up to 15 years |
| Battery | Alkaline, Lithium |
| Inputs | Redundant high frequency Wiegand sensor input |
| Inputs/Outputs/Interfaces | RS232 local configuration port plus RS232/485 serial interface |
| Temperature Sensors | RTD Temperature Sensor |
| Outputs | 4 Digital outputs (volume pulse + alarm), AMR-Ready and compatible with Itron, Aclara & Sensus AMR Devices |
| Configuration Software | MasterLink |
| Display | Multi-line Display with Single push button operation |
| Communication Protocols | Mercury Instruments |
| Communication | Optional class I Div. 1 cellular radio modem CloudLink 5G |
| Metrological Approvals | Measurement Canada (pending) |
| Explosion Protection | Ambient Temperature: -40 °C to +65 °C; CSA IECx (in progress):; Class I, Zone 2 AEx ic IIB Gc; IECEx: Ex ia IIB + H2 T4 Ga; IECEx: Ex ic IIB + H2 T4 Gc; Intrinsically Safe, Class I, Division 1 Groups B, C, D T4; Non Incendive Field Wiring, Class I, Division 2 Groups B, C, D T4; Non Incendive, Class I, Division 2 Groups B, C, D T4 |
| Protection Class | NEMAX 4 |
Values retain manufacturer model qualifications. Review Honeywell specifications ↗
Part Number
Published model / variant identifiers. A full ordering code requires the manufacturer configuration.
Published part numbers
1 parts
| Part Number | Description | Enquiry |
|---|---|---|
| TC250 | TEMPERATURE COMPENSATING INDEX | Request quotation |