TCI250 Temperature Compensating Index

TCI250 applies temperature compensation directly at a rotary gas meter, with redundant volume sensing and AMR-ready outputs.

TCI250 applies temperature compensation directly at a rotary gas meter, with redundant volume sensing and AMR-ready outputs. MasterLink supports setup, while optional CloudLink 5G communication enables automated reporting. The manufacturer lists extended-life battery choices and remote firmware updating, but explicitly describes hazardous-location and metrological approvals as pending or in progress.

Models: TCI250 Temperature Compensating Index

Features & Benefits

Mounting
Integrated rotary mounting
Remote update
Firmware over the air
Configuration
MasterLink
Approval status
Hazardous-location and metrological approvals pending/in progress
  • Supports automated data collection and fewer site visits

Applications

  • Gas billing, custody transfer and commercial or industrial metering

Detailed capabilities

TCI250 Temperature Compensating Index — product role

TCI250 applies temperature compensation directly at a rotary gas meter, with redundant volume sensing and AMR-ready outputs. MasterLink supports setup, while optional CloudLink 5G communication enables automated reporting. The manufacturer lists extended-life battery choices and remote firmware updating, but explicitly describes hazardous-location and metrological approvals as pending or in progress.

Manufacturer reference ↗

Temperature correction and direct mounting

TCI250 uses measured temperature and redundant volume sensing to compensate rotary-meter readings. The compact direct-mount design supports standardized deployment across different meter fleets. Its intended work includes distribution billing, custody transfer and commercial or industrial stations, where accurate temperature correction and low-complexity installation are important.

Manufacturer reference ↗

Connected data and security

AMR support includes the named Itron, Aclara and Sensus systems, with optional CloudLink 5G communication for automated transfer. The source discusses TLS and secure-development practices alongside remote visibility and reduced visits. These functions supplement the temperature index; they do not make it a pressure-and-temperature corrector.

Manufacturer reference ↗

Pending approvals

The published CSA/IECEx hazardous-location approvals, Division and Zone ratings, and metrological approvals are marked pending. That status must remain explicit when the product is presented for custody-transfer or hazardous-area projects, rather than treating the stated intended applications as evidence of completed certification.

Manufacturer reference ↗

Specifications

Applications & Compatibility

Compatible Meter Types
Compatible Meter Types; Dresser LMMA and B3; Romet RM and RMT
Applications
Accurate gas volume measurement with temperature compensation; Ideal replacement for mechanical TC indexes and Mercury TCI; Supports AMR (Automatic Meter Reading) connections
Mounting
Integrated Rotary mount for leading brand rotary gas meters

Processing & Performance Metrics

Temperature Accuracy
Maximum error at reference conditions: ±0.1% of reading
Accuracy
- Temperature: ±0.1% of reading; Including linearity, repeatability, and hysteresis; Maximum error over the full temperature range -40°F to 149°F (-40°C to 65°C)

Functional & Control Features

Remote Upgrade
via Firmware-over-the-air (FOTA)
Audit Trail
Single, configurable and flexible audit trail with up to 10 items w/ configurable interval: 1,5,10,15,30 minutes, hourly, daily, monthly, Year plus capacity hourly logging

Environmental Conditions

Ambient Temperature Effects
-40°F to 149°F (-40°C to 65°C)
Relative Humidity
0 to 95% (Non-condensing)

Electrical Specifications

External Power Supply
No
Power Supply
Battery powered
Battery Life
Alkaline receptacle: up to 5 years; Lithium batteries: up to 15 years
Battery
Alkaline, Lithium

I/O Capabilities

Inputs
Redundant high frequency Wiegand sensor input
Inputs/Outputs/Interfaces
RS232 local configuration port plus RS232/485 serial interface
Temperature Sensors
RTD Temperature Sensor
Outputs
4 Digital outputs (volume pulse + alarm), AMR-Ready and compatible with Itron, Aclara & Sensus AMR Devices

Software & Interface

Configuration Software
MasterLink
Display
Multi-line Display with Single push button operation

Communication & Protocols

Communication Protocols
Mercury Instruments
Communication
Optional class I Div. 1 cellular radio modem CloudLink 5G

Standards & Certifications

Metrological Approvals
Measurement Canada (pending)
Explosion Protection
Ambient Temperature: -40 °C to +65 °C; CSA IECx (in progress):; Class I, Zone 2 AEx ic IIB Gc; IECEx: Ex ia IIB + H2 T4 Ga; IECEx: Ex ic IIB + H2 T4 Gc; Intrinsically Safe, Class I, Division 1 Groups B, C, D T4; Non Incendive Field Wiring, Class I, Division 2 Groups B, C, D T4; Non Incendive, Class I, Division 2 Groups B, C, D T4
Protection Class
NEMAX 4
TCI250 Temperature Compensating Index — manufacturer page values
ParameterPublished value / configuration
Compatible Meter TypesCompatible Meter Types; Dresser LMMA and B3; Romet RM and RMT
ApplicationsAccurate gas volume measurement with temperature compensation; Ideal replacement for mechanical TC indexes and Mercury TCI; Supports AMR (Automatic Meter Reading) connections
MountingIntegrated Rotary mount for leading brand rotary gas meters
Temperature AccuracyMaximum error at reference conditions: ±0.1% of reading
Accuracy- Temperature: ±0.1% of reading; Including linearity, repeatability, and hysteresis; Maximum error over the full temperature range -40°F to 149°F (-40°C to 65°C)
Remote Upgradevia Firmware-over-the-air (FOTA)
Audit TrailSingle, configurable and flexible audit trail with up to 10 items w/ configurable interval: 1,5,10,15,30 minutes, hourly, daily, monthly, Year plus capacity hourly logging
Ambient Temperature Effects-40°F to 149°F (-40°C to 65°C)
Relative Humidity0 to 95% (Non-condensing)
External Power SupplyNo
Power SupplyBattery powered
Battery LifeAlkaline receptacle: up to 5 years; Lithium batteries: up to 15 years
BatteryAlkaline, Lithium
InputsRedundant high frequency Wiegand sensor input
Inputs/Outputs/InterfacesRS232 local configuration port plus RS232/485 serial interface
Temperature SensorsRTD Temperature Sensor
Outputs4 Digital outputs (volume pulse + alarm), AMR-Ready and compatible with Itron, Aclara & Sensus AMR Devices
Configuration SoftwareMasterLink
DisplayMulti-line Display with Single push button operation
Communication ProtocolsMercury Instruments
CommunicationOptional class I Div. 1 cellular radio modem CloudLink 5G
Metrological ApprovalsMeasurement Canada (pending)
Explosion ProtectionAmbient Temperature: -40 °C to +65 °C; CSA IECx (in progress):; Class I, Zone 2 AEx ic IIB Gc; IECEx: Ex ia IIB + H2 T4 Ga; IECEx: Ex ic IIB + H2 T4 Gc; Intrinsically Safe, Class I, Division 1 Groups B, C, D T4; Non Incendive Field Wiring, Class I, Division 2 Groups B, C, D T4; Non Incendive, Class I, Division 2 Groups B, C, D T4
Protection ClassNEMAX 4

Values retain manufacturer model qualifications. Review Honeywell specifications ↗

Part Number

Published model / variant identifiers. A full ordering code requires the manufacturer configuration.

TCI250 Temperature Compensating IndexRequest quotation ›

Published part numbers

1 parts

Part NumberDescriptionEnquiry
TC250TEMPERATURE COMPENSATING INDEXRequest quotation
Manufacturer sources

https://process.honeywell.com/us/en/products/gas/distribution/volume-converters/tci250-temperature-compensating-index

Last source check: 2026-11-02

TCI250 Product Image · Manufacturer ownership retained; republication licence not independently confirmed

ABID Automation LTD maintains this independent product reference. Honeywell owns its product names and trademarks. Current manufacturer documentation governs specification, availability and certification.

Your next project. A clear starting point.

Tell us about your facility and what you need to achieve.

CallSend enquiry