Volume Converters
EC250 Volume Corrector
EC250 corrects rotary-meter gas volumes using pressure and temperature measurements in a directly mounted package.
EC250 corrects rotary-meter gas volumes using pressure and temperature measurements in a directly mounted package. Redundant volume sensing and integrated differential-pressure monitoring support billing and meter-health checks. AMR interfaces and optional CloudLink 5G connectivity provide remote data access. The manufacturer explicitly marks several hazardous-location and metrological approvals as pending, so their status requires confirmation.
Models: EC250 Volume Corrector
Features & Benefits
- Mounting
- Direct rotary-meter mounting
- Monitoring
- Differential-pressure measurement and logging
- Connectivity
- AMR-ready, optional CloudLink 5G
- Supports remote meter-health assessment and billing accuracy
Applications
- Gas distribution, commercial and industrial metering, custody transfer
Detailed capabilities
EC250 Volume Corrector — product role
EC250 corrects rotary-meter gas volumes using pressure and temperature measurements in a directly mounted package. Redundant volume sensing and integrated differential-pressure monitoring support billing and meter-health checks. AMR interfaces and optional CloudLink 5G connectivity provide remote data access. The manufacturer explicitly marks several hazardous-location and metrological approvals as pending, so their status requires confirmation.
Correction and rotary-meter diagnostics
EC250 uses pressure and temperature measurements with redundant volume sensing. Direct rotary mounting supports mixed meter fleets, while integrated differential-pressure measurement and logging provide a continuing view of meter condition. This combines billing correction with a diagnostic task that would otherwise require manual differential-pressure checks at the installation.
Communications and security design
The device is AMR-ready for the named Itron, Aclara and Sensus ecosystems, with optional CloudLink 5G communication. The source identifies TLS encryption and secure-development standards in its cybersecurity discussion. Remote collection supports MDM or monitoring systems and is presented as a way to reduce routine field work.
Approval status and intended duties
Gas distribution, custody-transfer billing and commercial or industrial stations are the published applications. CSA and IECEx hazardous-location approvals, the listed Division/Zone classifications and metrological approvals are explicitly pending. Those qualifications remain part of the product content rather than being replaced by an unqualified approval claim.
Applications & Compatibility
- Compatible Meter Types
- Dresser LMMA and B3; Elster RABO; Romet RM and RMT
- Applications
- Commercial and Industrial Gas Distribution; Custody transfer Measurements; Supports AMR (Automatic Meter Reading) connections
Processing & Performance Metrics
- Temperature Accuracy
- Maximum error at reference conditions: ±0.1% of reading
- Long Term Stability
- Long-term drift - Pressure; Pressure Range > 15 PSI +/- 0.67% of full scale over 10 years; Pressure Range > 30PSI +/- 0.4% of full scale over 10 years; Pressure Range > 6 PSI +/- 1.3% of full scale over 10 year
- Pressure Accuracy
- Maximum error at reference conditions: ±0.04% of full scale
- Accuracy
- Maximum error over the full temperature range -40°F to 149°F (-40°C to 65°C) including linearity, repeatability, and hysteresis - Pressure:0.1% of full scale - Temperature: ±0.1% of reading
Functional & Control Features
- Compressibility
- Corrected volume calculation according to AGA-8 Gross (Methods 1&2) & AGA8 Detail, and NX-19
- Remote Upgrade
- via Firmware-over-the-air (FOTA)
- Audit Trail
- Single, configurable and flexible audit trail with up to 10 items with configurable interval: 1,5,10,15,30 minutes, hourly, daily, monthly, Year plus capacity hourly logging
Environmental Conditions
- Ambient Temperature Effects
- -40 to 149 deg F (-40 to 65 deg C)
- Relative Humidity
- 0 to 95% (Non-condensing)
Electrical Specifications
- External Power Supply
- No
- Power Supply
- Battery powered; No external power supply
- Battery Life
- Alkaline receptacle: up to 5 years; Lithium batteries: up to 15 years
- Battery
- Alkaline, Lithium
I/O Capabilities
- Inputs
- Redundant high frequency Wiegand sensor input
- Inputs/Outputs/Interfaces
- RS232 local configuration port plus RS232/485 serial interface
- Temperature Sensors
- RTD Temperature Sensor
- Integrated Sensors
- Optional differential pressure transmitter for rotary meter health insight
- Pressure Sensor
- 1 pressure, digital Plug and Play Pressure Transducer
- Outputs
- 4 Digital outputs (volume pulse + alarm), AMR-Ready and compatible with Itron, Aclara & Sensus AMR Devices
Software & Interface
- Configuration Software
- MasterLink
- Display
- Multi-line Display with Single push button operation
Communication & Protocols
- Communication Protocols
- Mercury Instruments
- Communication
- Optional class I Div. 1 cellular radio modem CloudLink 5G
Standards & Certifications
- Metrological Approvals
- Measurement Canada (pending)
- Explosion Protection
- Ambient Temperature: -40 to +65 deg C; CSA IECx (in progress); Class I, Zone 0 AEx ia IIB T4 Ga; Class I, Zone 2 AEx ic IIB Gc; Intrinsically Safe, Class I, Division 1 Groups B, C, D T4
- Protection Class
- NEMAX 4
Others
- Mounting Options
- Integrated Rotary mount for leading brand rotary gas meters
| Parameter | Published value / configuration |
|---|---|
| Compatible Meter Types | Dresser LMMA and B3; Elster RABO; Romet RM and RMT |
| Applications | Commercial and Industrial Gas Distribution; Custody transfer Measurements; Supports AMR (Automatic Meter Reading) connections |
| Temperature Accuracy | Maximum error at reference conditions: ±0.1% of reading |
| Long Term Stability | Long-term drift - Pressure; Pressure Range > 15 PSI +/- 0.67% of full scale over 10 years; Pressure Range > 30PSI +/- 0.4% of full scale over 10 years; Pressure Range > 6 PSI +/- 1.3% of full scale over 10 year |
| Pressure Accuracy | Maximum error at reference conditions: ±0.04% of full scale |
| Accuracy | Maximum error over the full temperature range -40°F to 149°F (-40°C to 65°C) including linearity, repeatability, and hysteresis - Pressure:0.1% of full scale - Temperature: ±0.1% of reading |
| Compressibility | Corrected volume calculation according to AGA-8 Gross (Methods 1&2) & AGA8 Detail, and NX-19 |
| Remote Upgrade | via Firmware-over-the-air (FOTA) |
| Audit Trail | Single, configurable and flexible audit trail with up to 10 items with configurable interval: 1,5,10,15,30 minutes, hourly, daily, monthly, Year plus capacity hourly logging |
| Ambient Temperature Effects | -40 to 149 deg F (-40 to 65 deg C) |
| Relative Humidity | 0 to 95% (Non-condensing) |
| External Power Supply | No |
| Power Supply | Battery powered; No external power supply |
| Battery Life | Alkaline receptacle: up to 5 years; Lithium batteries: up to 15 years |
| Battery | Alkaline, Lithium |
| Inputs | Redundant high frequency Wiegand sensor input |
| Inputs/Outputs/Interfaces | RS232 local configuration port plus RS232/485 serial interface |
| Temperature Sensors | RTD Temperature Sensor |
| Integrated Sensors | Optional differential pressure transmitter for rotary meter health insight |
| Pressure Sensor | 1 pressure, digital Plug and Play Pressure Transducer |
| Outputs | 4 Digital outputs (volume pulse + alarm), AMR-Ready and compatible with Itron, Aclara & Sensus AMR Devices |
| Configuration Software | MasterLink |
| Display | Multi-line Display with Single push button operation |
| Communication Protocols | Mercury Instruments |
| Communication | Optional class I Div. 1 cellular radio modem CloudLink 5G |
| Metrological Approvals | Measurement Canada (pending) |
| Explosion Protection | Ambient Temperature: -40 to +65 deg C; CSA IECx (in progress); Class I, Zone 0 AEx ia IIB T4 Ga; Class I, Zone 2 AEx ic IIB Gc; Intrinsically Safe, Class I, Division 1 Groups B, C, D T4 |
| Protection Class | NEMAX 4 |
| Mounting Options | Integrated Rotary mount for leading brand rotary gas meters |
Values retain manufacturer model qualifications. Review Honeywell specifications ↗
Resources
Resources linked from the manufacturer’s page. Confirm the document revision and applicable model before installation or ordering.
Honeywell resource listing ↗Part Number
Published model / variant identifiers. A full ordering code requires the manufacturer configuration.
Published part numbers
1 parts
| Part Number | Description | Enquiry |
|---|---|---|
| EC250 | ELECTRONIC VOLUME CORRECTOR | Request quotation |
Manufacturer sources
Last source check: 2026-11-02
EC250 Product Image · Manufacturer ownership retained; republication licence not independently confirmed
EC250 Product Alternate Image · Manufacturer ownership retained; republication licence not independently confirmed
EC250 Product Alternate Image2 · Manufacturer ownership retained; republication licence not independently confirmed
ABID Automation LTD maintains this independent product reference. Honeywell owns its product names and trademarks. Current manufacturer documentation governs specification, availability and certification.
Your next project. A clear starting point.
Tell us about your facility and what you need to achieve.