Turbine & Quantometers
Q75 - Quantometer
Q75 is a short-pattern turbine meter offered in several constructions, including cast bodies and spool pieces.
Q75 is a short-pattern turbine meter offered in several constructions, including cast bodies and spool pieces. The manufacturer identifies fiscal approval in a number of countries, without listing one universal jurisdictional approval. Sizes extend to large pipelines, while lubrication systems and high-frequency outputs form part of the available options for the selected configuration.
Models: Q75 - Quantometer
Features & Benefits
- Maximum pipe size
- DN750 / 30 in
- Options
- Lubrication systems and high-frequency output
- Multiple body and output arrangements
Applications
- Industrial gas measurement and jurisdiction-specific fiscal metering
Processing & Performance Metrics
- Accuracy
- ±1.5% from 0.2 Qmax to Qmax; ±3.0% from Qmin to 0.2 Qmax
Technical Specifications
- Flange Connections
- EN or ASME standards
- Suitable Media
- Natural Gas, Air, Methane, Nitrogen, Other Non-Corrosive Gases
- Pulse Output
- 2x Low Frequency (LF) Standard, High Frequency (HF) Optional
- Design Type
- Flanged or Sandwich
Environmental Conditions
- Temperature Range
- -10 to +60 deg C (others on request)
- Measuring Range
- Up to 1:20
Standards & Certifications
- Protection Class
- IP67 (Suitable for Outdoor Installation)
Overview
- Index Variants
- MI-2
Software & Interface
- Index Display
- 8-Digit Mechanical Roller Counter
Material Specifications
- Body Material
- Cast Iron or Steel
Applications & Compatibility
- Applications
- Consumption monitoring for burners, boilers, furnaces; In-plant allocation metering; Volume input for controls
- Mounting
- Horizontal Only
Mechanical & Physical Properties
- Meter Sizes
- DN 200 to DN 600 (8 to 24 in)
I/O Capabilities
- LF Pulsers
- IN-S10 (Standard), IN-S11/IN-S12 (Optional)
- HF Pulsers
- BI-ISM-Y1 Type
Industries / Applications & Compatibility
- Industries
- Heavy Industry, Petrochemicals, Steel, Power, Minerals, Heating
Electrical Specifications
- Flow Rate
- 6 to 25,000 m³/h
| Parameter | Published value / configuration |
|---|---|
| Accuracy | ±1.5% from 0.2 Qmax to Qmax; ±3.0% from Qmin to 0.2 Qmax |
| Flange Connections | EN or ASME standards |
| Suitable Media | Natural Gas, Air, Methane, Nitrogen, Other Non-Corrosive Gases |
| Pulse Output | 2x Low Frequency (LF) Standard, High Frequency (HF) Optional |
| Design Type | Flanged or Sandwich |
| Temperature Range | -10 to +60 deg C (others on request) |
| Measuring Range | Up to 1:20 |
| Protection Class | IP67 (Suitable for Outdoor Installation) |
| Index Variants | MI-2 |
| Index Display | 8-Digit Mechanical Roller Counter |
| Body Material | Cast Iron or Steel |
| Applications | Consumption monitoring for burners, boilers, furnaces; In-plant allocation metering; Volume input for controls |
| Mounting | Horizontal Only |
| Meter Sizes | DN 200 to DN 600 (8 to 24 in) |
| LF Pulsers | IN-S10 (Standard), IN-S11/IN-S12 (Optional) |
| HF Pulsers | BI-ISM-Y1 Type |
| Industries | Heavy Industry, Petrochemicals, Steel, Power, Minerals, Heating |
| Flow Rate | 6 to 25,000 m³/h |
Values retain manufacturer model qualifications. Review Honeywell specifications ↗
Resources
Resources linked from the manufacturer’s page. Confirm the document revision and applicable model before installation or ordering.
Honeywell resource listing ↗Part Number
Published model / variant identifiers. A full ordering code requires the manufacturer configuration.
Manufacturer sources
Last source check: 2026-11-02
Q75 - Quantometer Image · Manufacturer ownership retained; republication licence not independently confirmed
ABID Automation LTD maintains this independent product reference. Honeywell owns its product names and trademarks. Current manufacturer documentation governs specification, availability and certification.
Your next project. A clear starting point.