SmartLine ST800 Pressure Transmitters
SmartLine STF800 - Flange Mount
STF800 transmitters use a flange connection to mount at the tank, with several process-connection variants.
STF800 transmitters use a flange connection to mount at the tank, with several process-connection variants. Honeywell publishes STF828, STF832, STF82F and STF83F range and span combinations for selection. The instruments address measurement duties requiring stable readings, including natural-gas custody transfer and energy or material balances, subject to the chosen transmitter and installation.
Models: STF828, STF82F, STF832, STF83F
Features & Benefits
- Published variants
- STF828, STF832, STF82F and STF83F
Applications
- Natural-gas custody transfer
- Energy and material balances
Product videos
Overview
- Models
- STF828, STF82F, STF832, STF83F
Environmental Conditions
- Maximum Allowable Working Pressure (MAWP)
- Varies by flange class and material
- Ambient Temperature Limits
- -40 to +85 deg C (Ambient); -55 to +120 deg C (Storage)
- Relative Humidity
- 0 to 100% RH
- Measurement Type
- Flange Mounted Level (Hydrostatic Pressure)
- Rangeability
- Up to 100:1
- Stability
- Up to 0.01% of URL per year for 15 years
Communication Interfaces
- Process Interface Temp.
- Up to 175 deg C (350 deg F) for STF828, STF832
I/O Capabilities
- Process Connection Type
- 1/4 in NPT, 1/2 in NPT with Adapter, DIN, Flange: 2, 3, 4 in ANSI 150/300, DN50/80/100 PN40 DIN
- Marine Certification
- ABS, BV, DNV, KR, LR
- Response Time
- As fast as 90 ms millisecond
- Configuration
- External Zero, Span & Configuration Capability; Three-Button Local Configuration
Processing & Performance Metrics
- Maximum Turndown Ratio
- 100:1
- Minimum Span
- STF828/STF82F: 4 inH₂O (10 mbar); STF832/STF83F: 1 psi (0.07 bar)
- Accuracy
- Up to 0.0375% of span (standard), 0.025% (optional)
Communication & Protocols
- Output/Communications
- 4 to 20 mA, Honeywell DE, HART (v7.0), FOUNDATION Fieldbus
Functional & Control Features
- Sensor Technology
- Piezoresistive sensor with static pressure & temperature compensation
- Diagnostics
- Comprehensive On-Board Diagnostics, Plugged Impulse Line Detection (PILD) option
Mechanical & Physical Properties
- Wetted Materials
- 316L Stainless Steel, Hastelloy C-276, Monel 400
Standards & Certifications
- Safety Approvals
- SIL 2/3 certified, Dual Seal design, NAMUR NE-107 Extended Diagnostics
- Approvals
- FM, CSA, ATEX, IECEx, NEPSI, KOSHA, EAC, CCoE, UATR, SAEx, INMETRO, Marine (ABS, BV, DNV, KR, LR), IEC 61508 SIL 2/3
Technical Specifications
- STF828
- -400 to 400 inH2O (-1000 to 1000 mbar) | 4 to 400 inH2O (10 to 1000 mbar)
- STF832
- -100 to 100 psi (-7 to 7 bar) | 1 to 100 psi (0.07 to 7 bar)
- STF82F
- -400 to 400 inH2O (-1000 to 1000 mbar) | 1 to 400 inH2O (2.5 to 1000 mbar)
- STF83F
- -100 to 100 psi (-7 to 7 bar) | 1 to 100 psi (0.07 to 7 bar)
Electrical Specifications
- Supply Voltage
- DE: 15 to 49.3 VDC; FF: 9 to 32 VDC; HART: 10.8 to 42.4 VDC
- Pressure Range
- STF828/STF82F: 400 inH₂O (1000 mbar); STF832/STF83F: 100 psi (7 bar)
Software & Interface
- Fill Fluids
- Silicone Oil 200, CTFE, NEOBEE M-20, Silicone Oil 704
Wiring / Mechanical & Physical Properties
- Wiring
- Up to 16 AWG (1.5 mm diameter)
| Parameter | Published value / configuration |
|---|---|
| Models | STF828, STF82F, STF832, STF83F |
| Maximum Allowable Working Pressure (MAWP) | Varies by flange class and material |
| Ambient Temperature Limits | -40 to +85 deg C (Ambient); -55 to +120 deg C (Storage) |
| Relative Humidity | 0 to 100% RH |
| Measurement Type | Flange Mounted Level (Hydrostatic Pressure) |
| Rangeability | Up to 100:1 |
| Stability | Up to 0.01% of URL per year for 15 years |
| Process Interface Temp. | Up to 175 deg C (350 deg F) for STF828, STF832 |
| Process Connection Type | 1/4 in NPT, 1/2 in NPT with Adapter, DIN, Flange: 2, 3, 4 in ANSI 150/300, DN50/80/100 PN40 DIN |
| Marine Certification | ABS, BV, DNV, KR, LR |
| Response Time | As fast as 90 ms millisecond |
| Configuration | External Zero, Span & Configuration Capability; Three-Button Local Configuration |
| Maximum Turndown Ratio | 100:1 |
| Minimum Span | STF828/STF82F: 4 inH₂O (10 mbar); STF832/STF83F: 1 psi (0.07 bar) |
| Accuracy | Up to 0.0375% of span (standard), 0.025% (optional) |
| Output/Communications | 4 to 20 mA, Honeywell DE, HART (v7.0), FOUNDATION Fieldbus |
| Sensor Technology | Piezoresistive sensor with static pressure & temperature compensation |
| Diagnostics | Comprehensive On-Board Diagnostics, Plugged Impulse Line Detection (PILD) option |
| Wetted Materials | 316L Stainless Steel, Hastelloy C-276, Monel 400 |
| Safety Approvals | SIL 2/3 certified, Dual Seal design, NAMUR NE-107 Extended Diagnostics |
| Approvals | FM, CSA, ATEX, IECEx, NEPSI, KOSHA, EAC, CCoE, UATR, SAEx, INMETRO, Marine (ABS, BV, DNV, KR, LR), IEC 61508 SIL 2/3 |
| Display Options | Modular LCD (Alphanumeric or Advanced Graphics), Multiple Screens, Configurable units |
| Supply Voltage | DE: 15 to 49.3 VDC; FF: 9 to 32 VDC; HART: 10.8 to 42.4 VDC |
| Pressure Range | STF828/STF82F: 400 inH₂O (1000 mbar); STF832/STF83F: 100 psi (7 bar) |
| Fill Fluids | Silicone Oil 200, CTFE, NEOBEE M-20, Silicone Oil 704 |
| Wiring | Up to 16 AWG (1.5 mm diameter) |
| STF828 | -400 to 400 inH2O (-1000 to 1000 mbar) | 4 to 400 inH2O (10 to 1000 mbar) |
| STF832 | -100 to 100 psi (-7 to 7 bar) | 1 to 100 psi (0.07 to 7 bar) |
| STF82F | -400 to 400 inH2O (-1000 to 1000 mbar) | 1 to 400 inH2O (2.5 to 1000 mbar) |
| STF83F | -100 to 100 psi (-7 to 7 bar) | 1 to 100 psi (0.07 to 7 bar) |
Values retain manufacturer model qualifications. Review Honeywell specifications ↗
Resources
Resources linked from the manufacturer’s page. Confirm the document revision and applicable model before installation or ordering.
Honeywell resource listing ↗Part Number
Published model / variant identifiers. A full ordering code requires the manufacturer configuration.
Published part numbers
10 parts
| Part Number | Description | Enquiry |
|---|---|---|
| 30369468-501 | VENT PLUG KIT LOW DISPLACEMNT | Request quotation |
| 30369468-502 | MONEL VENT PLUG KIT | Request quotation |
| 30369468-503 | VENT PLUG KIT HASTELLOY | Request quotation |
| 30369468C001 | VENT PLUG W/CERTIFIC W/ 316 S/S | Request quotation |
| 30369468C003 | VENT/PLUG(HASTELLOY) W/CERT | Request quotation |
| 30679622-501 | REPL GASKET KIT CL41 | Request quotation |
| 30756445-508 | KIT GASKET PULP & PAPER ORING | Request quotation |
| 50049832-501 | ST700/800 ALUM CAP W/WINDOW | Request quotation |
| 50049832-521 | ST700/800 STAINLESS CAP W/WINDOW | Request quotation |
| 50049839-501 | TERMINAL BLOCK ASSY, PRESSURE HART/DE | Request quotation |
Manufacturer sources
Last source check: 2026-11-02
STF800_Flanged_Level-Transmitter-with-Adv-Display · Manufacturer ownership retained; republication licence not independently confirmed
ABID Automation LTD maintains this independent product reference. Honeywell owns its product names and trademarks. Current manufacturer documentation governs specification, availability and certification.
Your next project. A clear starting point.