Fire & Life Safety · Building Systems · Industrial Automation [email protected] +880 1347 561 256
Honeywell Process Measurement & Control

SmartLine ST800 Pressure Transmitters

SmartLine STD800 - Differential Pressure

SmartLine STD800 measures differential pressure using a piezoresistive sensor with static-pressure and temperature compensation.

SmartLine STD800 measures differential pressure using a piezoresistive sensor with static-pressure and temperature compensation. Published variants cover low differential-pressure spans through higher-pressure service. The family supports local configuration, diagnostics and integration with Experion PKS.

Models: STD810, STD815, STD820, STD830, STD870

Features & Benefits

Sensor Technology
Piezoresistive sensor with on-chip static pressure & temperature compensation
Diagnostics
Comprehensive On-board Diagnostics, Plugged Impulse Line Detection (PILD) option
Configuration
External Zero, Span & Configuration Capability; Three-Button Local Configuration
Display Options
Modular LCD (Alphanumeric or Advanced Graphics), Multiple Screens, Configurable Units

Applications

  • Combustion airflow
  • Hydrostatic tank measurement
  • Custody transfer
  • Energy and material balances

Product videos

Source discrepancy: the live specification tab lists up to 0.035% standard accuracy. Specification 34-ST-03-82 (December 2025), page 1, lists up to 0.0325% standard accuracy. Both list 0.025% as optional. The overview range table also differs from the document for STD870 lower range. Do not resolve these differences without checking the configured model.

Specifications

Processing & Performance Metrics

Accuracy
Up to 0.035% of span (standard), 0.025% (optional)
Minimum Span
STD810: 0.1 inH₂O (0.25 mbar); STD815: 0.5 inH₂O (1.25 mbar); STD820: 1 inH₂O (2.5 mbar); STD830: 1 psi (0.07 bar); STD870: 30 psi (2.1 bar)
Maximum Turndown Ratio
STD810: 100:1; STD815: 200:1; STD820: 400:1; STD830/STD870: 100:1

Wiring / Mechanical & Physical Properties

Wiring
Up to 16 AWG (1.5 mm diameter)

Mechanical & Physical Properties

Wetted Materials
316L Stainless Steel, Hastelloy C-276, Monel 400, Tantalum, Gold-Plated options
Head Gasket Materials
Glass-Filled PTFE (Standard), Viton, Graphite (Optional)

Electrical Specifications

Supply Voltage
DE: 15 to 49.3 VDC; FF: 9 to 32 VDC; HART: 10.8 to 42.4 VDC
Pressure Range
STD810: 10 inH₂O (25 mbar); STD815: 100 inH₂O (250 mbar); STD820: 400 inH₂O (1000 mbar); STD830: 100 psi (7 bar); STD870: 3000 psi (210 bar)

Environmental Conditions

Stability
Up to 0.01% of URL per year for 15 years
Relative Humidity
0 to 100% RH
Rangeability
Up to 400:1 (model dependent)
Maximum Allowable Working Pressure (MAWP)
Up to 4,500 psi (310 bar) Standard, 6,000 psi (420 bar) Optional (model dependent)
Ambient Temperature Limits
-40 to +85 deg C (Ambient), -55 to +120 deg C (Storage)

Functional & Control Features

Sensor Technology
Piezoresistive sensor with on-chip static pressure & temperature compensation
Diagnostics
Comprehensive On-board Diagnostics, Plugged Impulse Line Detection (PILD) option

Standards & Certifications

Safety Approvals
SIL 2/3 Certified, Dual Seal design, NAMUR NE-107 Extended Diagnostics
Approvals
FM, CSA, ATEX, IECEx, NEPSI, KOSHA, EAC, CCoE, UATR, SAEx, INMETRO, Marine (ABS, BV, DNV, KR, LR), IEC 61508 SIL 2/3

I/O Capabilities

Response Time
As fast as 90 ms millisecond
Process Connection Type
1/4 in NPT or 1/2 in NPT with Adapter (DIN compatible)
Mounting Bracket
Carbon Steel, 304 Stainless Steel, 316 Stainless Steel
Marine Certification
ABS, BV, DNV, KR, LR
Configuration
External Zero, Span & Configuration Capability; Three-Button Local Configuration

Communication & Protocols

Output/Communications
4 to 20 mA, Honeywell DE, HART (v7.0), FOUNDATION Fieldbus

Overview

Models
STD810, STD815, STD820, STD830, STD870

Software & Interface

Fill Fluids
Silicone Oil 200, Silicone Oil 704, CTFE, NEOBEE® M-20

Technical Specifications

STD810
-10 to 10 inH2O | -25 to 25 mbar
STD815
-100 to 100 inH2O | -249 to 249 mbar
STD820
-400 to 400 inH2O | -996 to 996 mbar
STD830
-100 to 100 psi | -6.9 to 6.9 bar
STD870
-3,000 to 3,000 psi | -207 to 207 bar
SmartLine STD800 - Differential Pressure — manufacturer page values
ParameterPublished value / configuration
AccuracyUp to 0.035% of span (standard), 0.025% (optional)
Minimum SpanSTD810: 0.1 inH₂O (0.25 mbar); STD815: 0.5 inH₂O (1.25 mbar); STD820: 1 inH₂O (2.5 mbar); STD830: 1 psi (0.07 bar); STD870: 30 psi (2.1 bar)
Maximum Turndown RatioSTD810: 100:1; STD815: 200:1; STD820: 400:1; STD830/STD870: 100:1
WiringUp to 16 AWG (1.5 mm diameter)
Wetted Materials316L Stainless Steel, Hastelloy C-276, Monel 400, Tantalum, Gold-Plated options
Head Gasket MaterialsGlass-Filled PTFE (Standard), Viton, Graphite (Optional)
Supply VoltageDE: 15 to 49.3 VDC; FF: 9 to 32 VDC; HART: 10.8 to 42.4 VDC
Pressure RangeSTD810: 10 inH₂O (25 mbar); STD815: 100 inH₂O (250 mbar); STD820: 400 inH₂O (1000 mbar); STD830: 100 psi (7 bar); STD870: 3000 psi (210 bar)
StabilityUp to 0.01% of URL per year for 15 years
Relative Humidity0 to 100% RH
RangeabilityUp to 400:1 (model dependent)
Maximum Allowable Working Pressure (MAWP)Up to 4,500 psi (310 bar) Standard, 6,000 psi (420 bar) Optional (model dependent)
Ambient Temperature Limits-40 to +85 deg C (Ambient), -55 to +120 deg C (Storage)
Sensor TechnologyPiezoresistive sensor with on-chip static pressure & temperature compensation
DiagnosticsComprehensive On-board Diagnostics, Plugged Impulse Line Detection (PILD) option
Safety ApprovalsSIL 2/3 Certified, Dual Seal design, NAMUR NE-107 Extended Diagnostics
ApprovalsFM, CSA, ATEX, IECEx, NEPSI, KOSHA, EAC, CCoE, UATR, SAEx, INMETRO, Marine (ABS, BV, DNV, KR, LR), IEC 61508 SIL 2/3
Response TimeAs fast as 90 ms millisecond
Process Connection Type1/4 in NPT or 1/2 in NPT with Adapter (DIN compatible)
Mounting BracketCarbon Steel, 304 Stainless Steel, 316 Stainless Steel
Marine CertificationABS, BV, DNV, KR, LR
ConfigurationExternal Zero, Span & Configuration Capability; Three-Button Local Configuration
Output/Communications4 to 20 mA, Honeywell DE, HART (v7.0), FOUNDATION Fieldbus
ModelsSTD810, STD815, STD820, STD830, STD870
Fill FluidsSilicone Oil 200, Silicone Oil 704, CTFE, NEOBEE® M-20
Display OptionsModular LCD (Alphanumeric or Advanced Graphics), Multiple Screens, Configurable Units
STD810-10 to 10 inH2O | -25 to 25 mbar
STD815-100 to 100 inH2O | -249 to 249 mbar
STD820-400 to 400 inH2O | -996 to 996 mbar
STD830-100 to 100 psi | -6.9 to 6.9 bar
STD870-3,000 to 3,000 psi | -207 to 207 bar

Values retain manufacturer model qualifications. Review Honeywell specifications ↗

Resources

Filter documents by type

Resources linked from the manufacturer’s page. Confirm the document revision and applicable model before installation or ordering.

Honeywell resource listing ↗

Part Number

Published model / variant identifiers. A full ordering code requires the manufacturer configuration.

Published part numbers

10 parts

Part NumberDescriptionEnquiry
30352520-508TEFLON PIPE PLUG KITRequest quotation
30369468-501VENT PLUG KIT LOW DISPLACEMNTRequest quotation
30369468-502MONEL VENT PLUG KITRequest quotation
30369468-503VENT PLUG KIT HASTELLOYRequest quotation
30369468C001VENT PLUG W/CERTIFIC W/ 316 S/SRequest quotation
30369468C003VENT/PLUG(HASTELLOY) W/CERTRequest quotation
30679622-501REPL GASKET KIT CL41Request quotation
30752770-503ANGLE BRACKET KIT DP/DHGP CSRequest quotation
30752770-504ANGLE BRACKET KIT LGP/LAP CS​Request quotation
30752770-603ANGLE BRACKET KIT DP/DHGP 304 SSRequest quotation
Manufacturer sources

https://process.honeywell.com/us/en/products/field-instruments/pressure-transmitters/smartline-st800-pressure-transmitters/smartline-std800-differential-pressure

Last source check: 2026-11-02

Smartline STD800 Differential Pressure Transmitter image · Manufacturer ownership retained; republication licence not independently confirmed

ABID Automation LTD maintains this independent product reference. Honeywell owns its product names and trademarks. Current manufacturer documentation governs specification, availability and certification.