Fire & Life Safety · Building Systems · Industrial Automation [email protected] +880 1347 561 256
Honeywell Process Measurement & Control

Multivariable Transmitters

SmartLine SMV800 Multivariable Transmitter

SMV800 combines differential pressure, static pressure and an external temperature measurement to calculate compensated mass or volume flow.

SMV800 combines differential pressure, static pressure and an external temperature measurement to calculate compensated mass or volume flow. Four published variants offer different pressure ranges, and temperature can come from a standard RTD or thermocouple. The transmitter applies established flow-calculation methods for steam, liquids and gases within the configured measurement application.

Models: SMA810, SMA845, SMG870, SMG890

Features & Benefits

Inputs
Differential pressure, static pressure and temperature
Calculated value
Compensated mass or volume flow

Applications

  • Gas, steam and liquid flow measurement

Product videos

Specifications

Software & Interface

Display
Modular LCD with multiple languages and graphical formats

Environmental Conditions

Storage Temperature Range
-55 to +120 deg C
Ambient Temperature Range
-40 to +85 deg C
Relative Humidity
0 to 100% RH
Rangeability
Up to 400:1

Communication & Protocols

Protocols Supported
HART 7, Honeywell DE, Modbus (RS-485)

I/O Capabilities

Response Time
Upto 2X per second for compensated flow measurement. millisecond

Functional & Control Features

Diagnostics
Advanced onboard diagnostics with critical and non-critical alerts

Technical Specifications

Model
DP | SP
SMA810
0-62.5 mbar | 0-7 bar A
SMA845
0-1000 mbar | 0-104 bar A
SMG870
0-1000 mbar | 0-310 bar g
SMG890
0-5000 mbar | 0-310 bar g​
SmartLine SMV800 Multivariable Transmitter — manufacturer page values
ParameterPublished value / configuration
DisplayModular LCD with multiple languages and graphical formats
Storage Temperature Range-55 to +120 deg C
Ambient Temperature Range-40 to +85 deg C
Relative Humidity0 to 100% RH
RangeabilityUp to 400:1
Protocols SupportedHART 7, Honeywell DE, Modbus (RS-485)
Response TimeUpto 2X per second for compensated flow measurement. millisecond
DiagnosticsAdvanced onboard diagnostics with critical and non-critical alerts
ModelDP | SP
SMA8100-62.5 mbar | 0-7 bar A
SMA8450-1000 mbar | 0-104 bar A
SMG8700-1000 mbar | 0-310 bar g
SMG8900-5000 mbar | 0-310 bar g​

Values retain manufacturer model qualifications. Review Honeywell specifications ↗

Resources

Filter documents by type

Resources linked from the manufacturer’s page. Confirm the document revision and applicable model before installation or ordering.

Honeywell resource listing ↗

Part Number

Published model / variant identifiers. A full ordering code requires the manufacturer configuration.

Published part numbers

10 parts

Part NumberDescriptionEnquiry
30679622-501REPL GASKET KIT CL41Request quotation
30756445-508KIT GASKET PULP & PAPER ORINGRequest quotation
50049846-506INTL MTD ADV IND KIT (EN,GE,FR,SP,RU,TU)Request quotation
50049846-507ADV. DIS KIT, SMV 800 MODBUS, WEST LANG.Request quotation
50086421-523TERMINAL STRIP WITH LP KIT FOR HART/DERequest quotation
50086421-532TERMINAL MODULE KIT WITH LP, MODBUSRequest quotation
50087087-503INTL MTD ADV IND KIT (EN,CH,JP)Request quotation
50087087-507ADV. DIS KIT, SMV 800 MODBUS, EAST LANG.Request quotation
50098718-501HART ELECTRONICS MODULERequest quotation
50098718-502SMV HART ELECTRONIC MODULE W/EXT BUTTONSRequest quotation
Manufacturer sources

https://process.honeywell.com/us/en/products/field-instruments/multivariable-transmitters/smartline-smv800-multivariable-transmitter

Last source check: 2026-11-02

SmartLine SMV800 Multivariable Transmitter Image · Manufacturer ownership retained; republication licence not independently confirmed

ABID Automation LTD maintains this independent product reference. Honeywell owns its product names and trademarks. Current manufacturer documentation governs specification, availability and certification.

Your next project. A clear starting point.

Tell us about your facility and what you need to achieve.

CallSend enquiry