Level Transmitters
SmartLine RM Series - Guided Level Meters
SmartLine RM guided radar meters use time-domain reflectometry along a probe to determine level, interface and distance, with derived volume and mass values.
SmartLine RM guided radar meters use time-domain reflectometry along a probe to determine level, interface and distance, with derived volume and mass values. Rigid and flexible probes support tanks and silos, including LPG and LNG duties. An optional second analogue output allows interface and level to be reported together in compatible installations.
Features & Benefits
- Technology
- TDR along rigid or flexible probes
- Output
- Optional second analogue output
- Avoids installation calibration requirements stated by Honeywell
Applications
- Blending tanks
- Separators
- Storage tanks
- LPG and LNG
- Powders and granulates
Detailed capabilities
What Is It?
The RM guided-radar meter provides distance, level, interface, volume and mass functions, with a second analog output available for simultaneous level/interface reporting. It supports the stated liquid and inventory applications, including LPG/LNG, and probes up to 35 m. Its dielectric statement of 1.6 or lower for powders/granulates differs from the separate SmartLine GWR page and must not be substituted across products.
How Does It Work?
Low-energy electromagnetic pulses travel along the rigid or flexible conductor. A material surface reflects part of the pulse according to its dielectric behavior, and the return time becomes the level measurement. The result is converted to 4–20 mA and/or a digital signal. Sharper pulses and stronger signal dynamics are described relative to conventional TDR devices, not as a separate free-space radar principle.
What Problems Does It Solve?
Guiding the signal along the probe limits sensitivity to the angle of repose in granular storage. Honeywell describes reduced sensitivity to conductivity, density, pressure and temperature changes relative to older measurement approaches. The source states no installation calibration/commissioning requirement for the meter, but the probe and process must still be selected within the published application envelope.
Software & Interface
- Display
- LCD, 9 Lines, 160x160 pixels, 8-step Grayscale, 4-button Keypad, 9 Languages
Technical Specifications
- Process Connection Type
- Thread (G 1/2, 1/2 NPT, 1-1/2 NPT), Flange (EN, ASME, JIS), Tri-Clamp, SMS
- Maximum Measuring Range
- Up to 35 m (115 ft) for cable probes (liquids/solids); Up to 8 m (26 ft) for double cable/rod
- Dielectric Constant
- Level (Direct Mode): ≥1.4 (Coaxial), ≥1.6 (Single/Double Probes); TBF Mode: ≥1.1
- Resolution
- 1 mm
I/O Capabilities
- Digital Communication
- PROFIBUS PA, FOUNDATION™ Fieldbus (4-wire, Galvanically Isolated)
Electrical Specifications
- Current Output Range
- 4 to 20 mA HART® or 3.8 to 20.5 mA (NAMUR NE 43)
- Power Supply
- 18 to 30 VDC (Device); 9 to 17.5 VDC (Bus, Ex); 9 to 32 VDC (Bus, non-Ex)
Standards & Certifications
- Protection Category
- IP66/IP67 (NEMA 6/6X)
- Approvals
- CE, ATEX, IECEx, FM, CSA, CEC, NEPSI, INMETRO, EMC, NAMUR NE 21/43, NACE MR0175/ISO 15156
Processing & Performance Metrics
- Measured Parameters
- Level, Distance, Interface, Volume, Mass
- Accuracy
- Interface: ±10 mm; Liquids: ±3 mm (Distance <10 m), ±0.03% (>10 m); Powders: ±20 mm
Environmental Conditions
- Ambient Temperature
- -40 to +80 deg C (-40 to +175 deg F)
Material Specifications
- Housing Material
- Aluminum, Stainless steel (316L)
Measurement & Sensor Related (Measurement Capabilities)
- Repeatability
- ±1 mm
Applications & Compatibility
- Applications
- Liquids, Solids (Powders, Granulates), Interface, Bypass Chamber, Stilling Well, Remote Display
Industries / Applications & Compatibility
- Industries
- Chemicals, Petrochemicals, Oil & Gas, Minerals & Mining, Water & Wastewater, Storage tanks
Others
- Storage Temperature
- -40 to +185 deg F; -40 to +85 deg C
| Parameter | Published value / configuration |
|---|---|
| Display | LCD, 9 Lines, 160x160 pixels, 8-step Grayscale, 4-button Keypad, 9 Languages |
| Process Connection Type | Thread (G 1/2, 1/2 NPT, 1-1/2 NPT), Flange (EN, ASME, JIS), Tri-Clamp, SMS |
| Maximum Measuring Range | Up to 35 m (115 ft) for cable probes (liquids/solids); Up to 8 m (26 ft) for double cable/rod |
| Dielectric Constant | Level (Direct Mode): ≥1.4 (Coaxial), ≥1.6 (Single/Double Probes); TBF Mode: ≥1.1 |
| Resolution | 1 mm |
| Digital Communication | PROFIBUS PA, FOUNDATION™ Fieldbus (4-wire, Galvanically Isolated) |
| Current Output Range | 4 to 20 mA HART® or 3.8 to 20.5 mA (NAMUR NE 43) |
| Power Supply | 18 to 30 VDC (Device); 9 to 17.5 VDC (Bus, Ex); 9 to 32 VDC (Bus, non-Ex) |
| Protection Category | IP66/IP67 (NEMA 6/6X) |
| Approvals | CE, ATEX, IECEx, FM, CSA, CEC, NEPSI, INMETRO, EMC, NAMUR NE 21/43, NACE MR0175/ISO 15156 |
| Measured Parameters | Level, Distance, Interface, Volume, Mass |
| Accuracy | Interface: ±10 mm; Liquids: ±3 mm (Distance <10 m), ±0.03% (>10 m); Powders: ±20 mm |
| Ambient Temperature | -40 to +80 deg C (-40 to +175 deg F) |
| Housing Material | Aluminum, Stainless steel (316L) |
| Repeatability | ±1 mm |
| Applications | Liquids, Solids (Powders, Granulates), Interface, Bypass Chamber, Stilling Well, Remote Display |
| Industries | Chemicals, Petrochemicals, Oil & Gas, Minerals & Mining, Water & Wastewater, Storage tanks |
| Storage Temperature | -40 to +185 deg F; -40 to +85 deg C |
Values retain manufacturer model qualifications. Review Honeywell specifications ↗
Resources
Resources linked from the manufacturer’s page. Confirm the document revision and applicable model before installation or ordering.
Honeywell resource listing ↗Manufacturer sources
Last source check: 2026-11-02
SmartLine RM Series – Guided Level Meters Image · Manufacturer ownership retained; republication licence not independently confirmed
SmartLine RM Series – Guided Level Meters Image 1 · Manufacturer ownership retained; republication licence not independently confirmed
ABID Automation LTD maintains this independent product reference. Honeywell owns its product names and trademarks. Current manufacturer documentation governs specification, availability and certification.
Your next project. A clear starting point.
Tell us about your facility and what you need to achieve.