Fire & Life Safety · Building Systems · Industrial Automation [email protected] +880 1347 561 256
Honeywell Process Measurement & Control

Probes & Pulsers

PR6/PR7

PR6 and PR7 are self-contained solid-state pulse units for compatible Elster water meters.

PR6 and PR7 are self-contained solid-state pulse units for compatible Elster water meters. They support mobile or fixed AMR collection and major data loggers without external power. Residential versions attach by a push fit, while bulk meters use screws; fixed-network arrangements can generate backflow alarms, and tamper-evident labels reveal attempted removal.

Features & Benefits

Protection
IP68
Residential battery design
12–14 years in normal use
Power
Self contained
  • Quick fitting to pre-equipped meters

Applications

  • Water AMR and data logging

Detailed capabilities

PR6/PR7 — purpose and arrangement

PR6 and PR7 are self-contained solid-state pulse units for compatible Elster water meters. They support mobile or fixed AMR collection and major data loggers without external power. Residential versions attach by a push fit, while bulk meters use screws; fixed-network arrangements can generate backflow alarms, and tamper-evident labels reveal attempted removal.

Manufacturer reference ↗

Self-contained pulse collection

PR6 and PR7 need no external supply and connect compatible Elster meters to loggers or AMR systems. Residential attachment is push-fit, while bulk arrangements use thumb screws or screws. The source gives a normal-use residential battery design of twelve to fourteen years and IP68 construction, keeping the service statement tied to that usage context.

Manufacturer reference ↗

Mobile and fixed networks

The pulsers support walk-by collection and fixed reading, with automatic backflow alarms in the fixed-network arrangement. Tamper-evident labels can expose attempted removal. This joins consumption pulse generation with installation and monitoring features, while the selected unit still needs to match the meter’s prepared interface.

Manufacturer reference ↗

Specifications

General Overview

Applications
Domestic water meters and bulk (Woltman) meters
Product Type
Pulse output module (PR6/PR7)
Intended Use
High‑quality, reliable transmission of meter readings

Product Identification

Technology
Contact‑free resonant target scanning technology

Electrical & Power

Sink Current
Maximum 30 mA
Power Supply
3.6 VDC lithium battery or external 3.6 VDC supply
Output Voltage
Maximum 30 VDC

Outputs

Pulse Width
PR6: 80 ms (K=1); 100 ms (K≥10); PR7: 10 ms (K=1); 100 ms (K≥10)

Interfaces

Output Channels
Two outputs (Channel 1 and Channel 2)
Maximum Pulse Rate
75 Hz (meter‑dependent)

Operating Conditions

Operating Temperature Range
-15 to +70 deg C
Humidity
Up to 100% RH

Measurement & Metrology

K‑Factor Options
1, 10, 100, 1000 (model dependent)

Protection

Ingress Protection
IP68

Prepayment (STS)

Data Integrity
Parity between mechanical register and transmitted data ensured

Installation & Configuration

Compatible Meter Types
PR6: V200, V200P, V210, V210P, C4000 Bypass Meters; PR7: H4000, H4200, S2000, C4000 Main Meter, C3100 Main Meter

Physical

Cable Length
PR6: 2 m; PR7: 5 m

Power

Battery Lifetime
Up to 10 years (at 25 deg C environmental temperature)

Safety & Compliance

Approvals
Designed in compliance with Elster/Honeywell metrological systems
PR6/PR7 — manufacturer page values
ParameterPublished value / configuration
ApplicationsDomestic water meters and bulk (Woltman) meters
Product TypePulse output module (PR6/PR7)
Intended UseHigh‑quality, reliable transmission of meter readings
TechnologyContact‑free resonant target scanning technology
Sink CurrentMaximum 30 mA
Power Supply3.6 VDC lithium battery or external 3.6 VDC supply
Output VoltageMaximum 30 VDC
Pulse WidthPR6: 80 ms (K=1); 100 ms (K≥10); PR7: 10 ms (K=1); 100 ms (K≥10)
Output ChannelsTwo outputs (Channel 1 and Channel 2)
Maximum Pulse Rate75 Hz (meter‑dependent)
Operating Temperature Range-15 to +70 deg C
HumidityUp to 100% RH
K‑Factor Options1, 10, 100, 1000 (model dependent)
Ingress ProtectionIP68
Data IntegrityParity between mechanical register and transmitted data ensured
Compatible Meter TypesPR6: V200, V200P, V210, V210P, C4000 Bypass Meters; PR7: H4000, H4200, S2000, C4000 Main Meter, C3100 Main Meter
Cable LengthPR6: 2 m; PR7: 5 m
Battery LifetimeUp to 10 years (at 25 deg C environmental temperature)
ApprovalsDesigned in compliance with Elster/Honeywell metrological systems

Values retain manufacturer model qualifications. Review Honeywell specifications ↗

Resources

Filter documents by type

Resources linked from the manufacturer’s page. Confirm the document revision and applicable model before installation or ordering.

Honeywell resource listing ↗

Part Number

Published part numbers

10 parts

Part NumberDescriptionEnquiry
2925M1222PULSER, INDUCTIVE, PR7 10:10Request quotation
2925M1264INDUCTIVE PR7 K1:1000Request quotation
EB000PROBE ASY+1/2M CABLERequest quotation
LU2925M1221BI-DIRECTIONAL INDUCTIVE PULSER PR6 1:1Request quotation
LU2925M1223BI-DIRECTIONAL INDUCT PULSER PR7 1:Request quotation
LU2925M1261INDUCTIVE PULSER PR6 - 1:100Request quotation
LU2925M1262INDUCTIVE PULSER PR6 - 1:1000Request quotation
LU2925M1265FALCON PULSER-PR6-1:10Request quotation
LU2925M1280PR7 pulse out module 10:100, 5m cableRequest quotation
LU2925M1291PULSER PR6 1:1 -SAURRequest quotation
Manufacturer sources

https://process.honeywell.com/us/en/products/utilities/water/digital-metering/probes-and-pulsers/pr6-pr7

Last source check: 2026-11-02

PR6/PR7 product image · Manufacturer ownership retained; republication licence not independently confirmed

ABID Automation LTD maintains this independent product reference. Honeywell owns its product names and trademarks. Current manufacturer documentation governs specification, availability and certification.

Your next project. A clear starting point.

Tell us about your facility and what you need to achieve.

CallSend enquiry