Volumetric Meters
V300 Volumetric Water Meter
V300, also identified as KG2000, measures water with a rotary-piston volumetric mechanism.
V300, also identified as KG2000, measures water with a rotary-piston volumetric mechanism. A thermoplastic chamber resists aggressive water and limits wear, while the design permits different pipeline orientations. Pulse units can be added without interrupting supply, providing a route to remote reading alongside its local kilolitre and litre registration.
Models: V300 Volumetric Water Meter
Features & Benefits
- Size
- 50 mm
- Flow range
- 0.15–30 kl/h
- Maximum temperature
- 50 °C
- Maximum pressure
- 1,400 kPa
- Measuring chamber is designed for low wear and no lifetime recalibration
Applications
- Water volume measurement
Detailed capabilities
V300 Volumetric Water Meter — purpose and arrangement
V300, also identified as KG2000, measures water with a rotary-piston volumetric mechanism. A thermoplastic chamber resists aggressive water and limits wear, while the design permits different pipeline orientations. Pulse units can be added without interrupting supply, providing a route to remote reading alongside its local kilolitre and litre registration.
Measuring chamber and installation
V300 uses a thermoplastic rotary-piston chamber intended to resist aggressive water and reduce wear. It can be installed horizontally, vertically or inclined, with a readable kilolitre/litre register. The manufacturer describes a low starting flow and operation without recalibration during service, while pulse units can be fitted without stopping the water supply.
Published meter envelope
The page identifies a fifty-millimeter meter,0.15–30kl/h flow, fifty-degree water limit and1,400kPa maximum working pressure. It also cites Australian AS3565.1-1998 class3. Those facts describe the published V300/KG2000 configuration; they are not transferred to the residential V100/V200 families simply because those also use volumetric measurement.
Performance
- Accuracy
- High accuracy across wide flow range, including very low flows
Operating Conditions
- Working Temperature Range
- 0.3 to 30 deg C
- Operating Temperature Range
- 0.3 to 50 deg C
Pressure Ratings
- Working Pressure
- 1400 kPa
Dimensions & Sizes
- Nominal Diameter
- DN50 (Q3/Q1 = 160)
General Overview
- Meter Types
- Volumetric rotary piston water meter
- Measurement Type
- Volumetric (direct measurement)
- Installation Orientation
- Horizontal, vertical, or inclined without accuracy loss
- Applications
- Cold potable (drinking) water measurement
Measurement
- Measurement Principle
- Positive displacement (rotary piston)
- Flow Rate
- Minimum Flowrate (Q1): 156 l/h; Permanent Flowrate (Q3): 25 kL/h; Transitional Flowrate (Q2): 250 l/h
Physical
- Dimensions
- 300 mm Length x 348 mm Height x 223 mm Width
Safety & Compliance
- Approvals
- NMI R49‑1 Class 2, AS 3565.1‑2010
| Parameter | Published value / configuration |
|---|---|
| Accuracy | High accuracy across wide flow range, including very low flows |
| Working Temperature Range | 0.3 to 30 deg C |
| Operating Temperature Range | 0.3 to 50 deg C |
| Working Pressure | 1400 kPa |
| Nominal Diameter | DN50 (Q3/Q1 = 160) |
| Meter Types | Volumetric rotary piston water meter |
| Measurement Type | Volumetric (direct measurement) |
| Installation Orientation | Horizontal, vertical, or inclined without accuracy loss |
| Applications | Cold potable (drinking) water measurement |
| Measurement Principle | Positive displacement (rotary piston) |
| Flow Rate | Minimum Flowrate (Q1): 156 l/h; Permanent Flowrate (Q3): 25 kL/h; Transitional Flowrate (Q2): 250 l/h |
| Dimensions | 300 mm Length x 348 mm Height x 223 mm Width |
| Approvals | NMI R49‑1 Class 2, AS 3565.1‑2010 |
Values retain manufacturer model qualifications. Review Honeywell specifications ↗
Resources
Resources linked from the manufacturer’s page. Confirm the document revision and applicable model before installation or ordering.
Honeywell resource listing ↗Part Number
Published model / variant identifiers. A full ordering code requires the manufacturer configuration.
Published part numbers
10 parts
| Part Number | Description | Enquiry |
|---|---|---|
| LUHPL7004 | CHECK VALVE ASSEMBLY | Request quotation |
| LUI121 | CONNS 1 1/2" BSP RF | Request quotation |
| LUMEN4071 | SENSOR & CARRIER ASSEMBLY | Request quotation |
| LUPSM5807 | V100C060M260EXRNM | Request quotation |
| MEB0450 | V100-t Probe Screw | Request quotation |
| MEB7454 | PULSE PROBE & CABLE, V100 | Request quotation |
| MFM4001-00 | METER, 50MM V300, STD | Request quotation |
| MFM4001-00SYD | METER, 50MM V300, STD, (SYD WATER) | Request quotation |
| MFM4001-00WC | METER, 50MM V300, STD, (WATER CORP) | Request quotation |
| MFM4001-01 | METER, 50MM V300, GRV | Request quotation |
Manufacturer sources
Last source check: 2026-11-02
V300 product image · Manufacturer ownership retained; republication licence not independently confirmed
ABID Automation LTD maintains this independent product reference. Honeywell owns its product names and trademarks. Current manufacturer documentation governs specification, availability and certification.
Your next project. A clear starting point.
Tell us about your facility and what you need to achieve.