Irrigation Meters
R1200 Paddle Wheel Irrigation Meter
R1200 uses a paddle-wheel arrangement that leaves the water passage open for suspended solids.
R1200 uses a paddle-wheel arrangement that leaves the water passage open for suspended solids. A removable mechanism simplifies service, while its dry register and wear-resistant materials suit agricultural installations. Horizontal and vertical orientations are permitted, and an optional reed pulser provides output, with temperature and pressure selected within the published operating limits.
Models: R1200 Paddle Wheel Irrigation Meter
Features & Benefits
- Sizes
- DN50–200
- Register
- IP68 dry dial
- PN
- 10 or 16 bar
- Temperature
- 30 °C maximum operating, operation guaranteed to 50 °C
- Unrestricted flow reduces jamming by suspended material
Applications
- Agricultural irrigation measurement
General Overview
- Applications
- Irrigation, raw water, untreated water, wastewater, borehole, agriculture
- Nominal Sizes
- DN50 to DN200
- Meter Types
- Paddle wheel irrigation water meter
Classes
- Temperature Class
- T30
Flow & Performance
- Starting Flow Rate
- 125 to 1800 l/h (size dependent)
Mechanical & Physical
- Rotor Position
- Outside main flow stream
- Lens Material
- Tempered mineral glass
Functional Features
- Register Type
- Hermetically sealed dry dial
Protection & Environmental
- Register Protection
- IP68
Installation & Configuration
- Orientation
- Horizontal and Vertical
Pressure Ratings
- Nominal Pressure
- 10/16 bar
Operating Conditions
- Maximum Operating Temperature
- 30 deg C (up to 50 deg C allowed)
Construction
- Housing Material
- Epoxy resin-coated cast iron
Physical
- Dimensions
- 200 to 350 mm L x 250 to 378 mm H x 165 to 340 mm Diameter
Safety & Compliance
- Approvals
- Directive 2004/22/EC, MID Ratio R40 (Q3/Q1)
| Parameter | Published value / configuration |
|---|---|
| Applications | Irrigation, raw water, untreated water, wastewater, borehole, agriculture |
| Nominal Sizes | DN50 to DN200 |
| Meter Types | Paddle wheel irrigation water meter |
| Temperature Class | T30 |
| Starting Flow Rate | 125 to 1800 l/h (size dependent) |
| Rotor Position | Outside main flow stream |
| Lens Material | Tempered mineral glass |
| Register Type | Hermetically sealed dry dial |
| Register Protection | IP68 |
| Orientation | Horizontal and Vertical |
| Nominal Pressure | 10/16 bar |
| Maximum Operating Temperature | 30 deg C (up to 50 deg C allowed) |
| Housing Material | Epoxy resin-coated cast iron |
| Dimensions | 200 to 350 mm L x 250 to 378 mm H x 165 to 340 mm Diameter |
| Approvals | Directive 2004/22/EC, MID Ratio R40 (Q3/Q1) |
Values retain manufacturer model qualifications. Review Honeywell specifications ↗
Resources
Resources linked from the manufacturer’s page. Confirm the document revision and applicable model before installation or ordering.
Honeywell resource listing ↗Part Number
Published model / variant identifiers. A full ordering code requires the manufacturer configuration.
Published part numbers
10 parts
| Part Number | Description | Enquiry |
|---|---|---|
| GMWI125 | COMPTEUR D'IRRIGATION À HÉLICE DN125 | Request quotation |
| GMWI150 | COMPTEUR D'IRRIGATION À HÉLICE DN150 | Request quotation |
| GMWI200 | COMPTEUR D'IRRIGATION À HÉLICE DN200 | Request quotation |
| GMWI50 | COMPTEUR D'IRRIGATION À HÉLICE DN50 | Request quotation |
| GMWI65 | COMPTEUR D'IRRIGATION À HÉLICE DN65 | Request quotation |
| GMWI80 | COMPTEUR D'IRRIGATION À HÉLICE DN80 | Request quotation |
| QQC14041 | R1200 40 40 050 200 N P2 | Request quotation |
| QQC14045 | R1200 63 40 065 200 N P2 | Request quotation |
| QQC14050 | R1200 63 40 080 225 N P2 | Request quotation |
| QQC14055 | R1200 100 40 100 250 N P2 | Request quotation |
Manufacturer sources
Last source check: 2026-11-02
R1200 product image · Manufacturer ownership retained; republication licence not independently confirmed
ABID Automation LTD maintains this independent product reference. Honeywell owns its product names and trademarks. Current manufacturer documentation governs specification, availability and certification.
Your next project. A clear starting point.
Tell us about your facility and what you need to achieve.