Test Equipment
Dry Test Meters
Dry Test Meters measure gas for field or laboratory testing where the sample is not saturated with water vapor.
Dry Test Meters measure gas for field or laboratory testing where the sample is not saturated with water vapor. The official page identifies this testing role but publishes little model-specific narrative. Actual meter size, capacity and test conditions must therefore follow the selected manufacturer's test-meter documentation rather than a single specification for the entire offering.
Models: DTM-200A, DTM-325
Features & Benefits
- Gas condition
- Unsaturated with water vapor
Applications
- Field and laboratory gas testing
Flow & Performance
- Angular Error Control
- Valve motion eliminates angular errors
General Overview
- Usage Benefits
- Field and laboratory gas testing
- Product Type
- Dry test gas meter
- Models
- DTM-200A, DTM-325
- Meter Types
- Diaphragm-type dry test meter
- Measurement Type
- Accurate volume measurement of gases
Operating Conditions
- Temperature Gauge
- -40 to 160 deg F (-40 to 70 deg C)
Measurement & Metrology
- Special Indexes
- 1/10 ft³, 1 ft³, 1 L, 10 L, 100 L options
- Dial Size
- 6 in Circular Dial
- Dial Resolution
- 1/10 ft³ to 100 L (model dependent)
Performance
- Pressure Gauges
- DTM-200A: 0 to 5 psig; DTM-325: 0 to 15 psig
Functional Features
- Portability
- Carrying handle provided
Capacity
- Flow Capacity
- DTM-200A: ~200 CFH or 5600 L/h; DTM-325: ~325 CFH or 9200 L/h
Construction
- Coating Type
- Polyester primer with polyurethane top coat
- Body Material
- One-piece die-cast aluminum
Safety & Compliance
- Approvals
- Certificate of Accuracy available
Product Identification
- Application Medium
- Hydrocarbon and non-corrosive gases
| Parameter | Published value / configuration |
|---|---|
| Angular Error Control | Valve motion eliminates angular errors |
| Usage Benefits | Field and laboratory gas testing |
| Product Type | Dry test gas meter |
| Models | DTM-200A, DTM-325 |
| Meter Types | Diaphragm-type dry test meter |
| Measurement Type | Accurate volume measurement of gases |
| Temperature Gauge | -40 to 160 deg F (-40 to 70 deg C) |
| Special Indexes | 1/10 ft³, 1 ft³, 1 L, 10 L, 100 L options |
| Dial Size | 6 in Circular Dial |
| Dial Resolution | 1/10 ft³ to 100 L (model dependent) |
| Pressure Gauges | DTM-200A: 0 to 5 psig; DTM-325: 0 to 15 psig |
| Portability | Carrying handle provided |
| Flow Capacity | DTM-200A: ~200 CFH or 5600 L/h; DTM-325: ~325 CFH or 9200 L/h |
| Coating Type | Polyester primer with polyurethane top coat |
| Body Material | One-piece die-cast aluminum |
| Approvals | Certificate of Accuracy available |
| Application Medium | Hydrocarbon and non-corrosive gases |
Values retain manufacturer model qualifications. Review Honeywell specifications ↗
Resources
Resources linked from the manufacturer’s page. Confirm the document revision and applicable model before installation or ordering.
Honeywell resource listing ↗Part Number
Published model / variant identifiers. A full ordering code requires the manufacturer configuration.
Published part numbers
10 parts
| Part Number | Description | Enquiry |
|---|---|---|
| 11607G038 | AXLE SHAFT&GEAR DTM-200 | Request quotation |
| 11607G039 | AXLE SHAFT&GEAR DTM-325 | Request quotation |
| 22571P051 | CLIP SPR DTM | Request quotation |
| 25276G075 | CR FR CR &TANG ASSY DTM | Request quotation |
| 25276G079 | CR FR CR &TANG ASSY DTM 325 | Request quotation |
| 25276G131 | CR CR FR&TAN DTM 2001/7' | Request quotation |
| 35758P013 | WASHER NYLON DTM | Request quotation |
| 39451P053 | VALVE SEAT PHEN AL175 | Request quotation |
| 39643P802 | DIAL 1 LITER (DTM) FAM | Request quotation |
| 39643P803 | DIAL 1/10 CU FT. (DTM) FAM | Request quotation |
Manufacturer sources
https://process.honeywell.com/us/en/products/utilities/gas/test-equipment/dry-test-meters
Last source check: 2026-11-02
Dry Test Meters image · Manufacturer ownership retained; republication licence not independently confirmed