Fire & Life Safety · Building Systems · Industrial Automation [email protected] +880 1347 561 256
Honeywell Process Measurement & Control

Valves

Excess Flow Valves

Perfection Excess Flow Valves close automatically when gas flow exceeds a critical level.

Perfection Excess Flow Valves close automatically when gas flow exceeds a critical level. Flow force moves a ball against its seat; after downstream damage is repaired, bleed or bypass flow can equalize pressure and reopen the automatic-reset version. A full shut-off version is also offered, and that configuration requires manual resetting.

Features & Benefits

Trigger
Excess flow
Reset
Automatic equalization, or manual on full-shut-off version
  • Limits major gas leakage after downstream damage

Applications

  • Gas service excess-flow protection

Specifications

Safety & Compliance

Approvals
ASTM F2138, ASTM F1802

General Overview

Valve Type
Excess Flow Valve
Primary Function
Automatically limits gas flow during line rupture

Construction

Valve Body Material
Stainless Steel (stamped)
Valve Ball Material
Precision‑ground Nylon
Elastomer/Seal Material
Buna‑Nitrile

Dimensions & Sizes

Service Line Size
1/2 CTS, 3/4 IPS, 1 CTS, 1 IPS

Functional Features

Reset Type
Bleed‑by automatic reset

Protection & Compliance

Regulatory Compliance
U.S. DOT CFR Title 49, Part 192.381

Flow & Performance

Rated Flow Capacities
400, 600, 800, 1100, 1800 SCFH

Mechanical & Physical

Fitting Configuration
Tapping Tee, Shut‑off Valve, Stick, Permasert

Media & Industry

Compatible Media
Gas
Excess Flow Valves — manufacturer page values
ParameterPublished value / configuration
ApprovalsASTM F2138, ASTM F1802
Valve TypeExcess Flow Valve
Primary FunctionAutomatically limits gas flow during line rupture
Valve Body MaterialStainless Steel (stamped)
Valve Ball MaterialPrecision‑ground Nylon
Elastomer/Seal MaterialBuna‑Nitrile
Service Line Size1/2 CTS, 3/4 IPS, 1 CTS, 1 IPS
Reset TypeBleed‑by automatic reset
Regulatory ComplianceU.S. DOT CFR Title 49, Part 192.381
Rated Flow Capacities400, 600, 800, 1100, 1800 SCFH
Fitting ConfigurationTapping Tee, Shut‑off Valve, Stick, Permasert
Compatible MediaGas

Values retain manufacturer model qualifications. Review Honeywell specifications ↗

Resources

Filter documents by type
NameLast checkedType
NIST Data Sheet ↗2026-11-02PDF
EFV Data Sheet ↗2026-11-02PDF

Resources linked from the manufacturer’s page. Confirm the document revision and applicable model before installation or ordering.

Honeywell resource listing ↗

Part Number

Published part numbers

10 parts

Part NumberDescriptionEnquiry
50561025GNKIT STICK 1IPS-SDR 11.0 FLP2600 BSC XMDRequest quotation
51102010GNSTICK FLP11 BSCxS/F 1CTS-099 XMD BRG SLVRequest quotation
51102GNSTICK,FLP8 BSCXS/F 1T099 XMDRequest quotation
51128010GNSTICK FLP4 BSC 1/2IPS-SDR9.3 PE4710Request quotation
51128011GNSTICK FLP800 BSC 1/2 IPS-SDR 9.3 XMDRequest quotation
51128013GNSTICK FLP1100 1/2IPS-SDR 9.3 BSC XMDRequest quotation
51128017GNSTICK FLP600 BSC 1/2IPS-SDR 9.3 PE4710Request quotation
51128023STICK FLP800 BSC 1/2 IPS-SDR 9.3 4710/MDRequest quotation
51128031GNSTICK FLP600 BSC 3/4CTS-.090 XMDRequest quotation
51128033GNSTICK FLP1100 BSC 3/4CTS-.090 XMDRequest quotation
Manufacturer sources

https://process.honeywell.com/us/en/products/utilities/gas/perfection-distribution-products/valves/excess-flow-valves

Last source check: 2026-11-02

Excess Flow Valves product image · Manufacturer ownership retained; republication licence not independently confirmed

ABID Automation LTD maintains this independent product reference. Honeywell owns its product names and trademarks. Current manufacturer documentation governs specification, availability and certification.

Your next project. A clear starting point.

Tell us about your facility and what you need to achieve.

CallSend enquiry