Fire & Life Safety · Building Systems · Industrial Automation [email protected] +880 1347 561 256
Honeywell Process Measurement & Control

Meter Hardware & Accessories

Critical Flow Provers

The Sonic Nozzle Flow Prover calibrates gas meters by passing gas or air through the meter and the prover.

The Sonic Nozzle Flow Prover calibrates gas meters by passing gas or air through the meter and the prover. The operator times the registration of a chosen volume with a stopwatch. This provides a critical-flow proving method, with the particular nozzle and test arrangement selected according to the meter and required calibration procedure.

Features & Benefits

Method
Sonic-nozzle critical-flow proving
Timing
Stopwatch over selected registered volume

Applications

  • Gas meter calibration

Specifications

Performance

Accuracy
±0.15% (standard time)
Test Pressure Range
3.6 to 1000 psig
Pressure Ratings
Method A: 500 psig, Method B: 1000 psig

Dimensions & Sizes

Throat Diameter Range
~0.094 to 0.625 in

Measurement & Metrology

Test Media
Air and Natural Gas

Operating Conditions

Temperature Range
Method A: 20 to 100 deg F, Method B: 0 to 200 deg F

Functional Features

Standard Time
Time for 1 cubic foot of air at 60 deg F and 10 psig inlet pressure

Construction

Seal Type
O-ring seals on nozzle flange
Nozzle Material
Stainless Steel
Components
Sonic flow nozzles, prover holder, accessories

Flow & Performance

Recommended Flow Points
10 to 20%, ~50%, 80 to 100% of meter capacity

General Overview

Function
Provides precise gas flow measurement and calibration for meters
Applications
Gas meter testing and calibration

Measurement

Flow Rate
250 to 6000 scfh

Installation & Configuration

Compatibility
Designed for 2 in critical flow prover holders
Critical Flow Provers — manufacturer page values
ParameterPublished value / configuration
Accuracy±0.15% (standard time)
Test Pressure Range3.6 to 1000 psig
Pressure RatingsMethod A: 500 psig, Method B: 1000 psig
Throat Diameter Range~0.094 to 0.625 in
Test MediaAir and Natural Gas
Temperature RangeMethod A: 20 to 100 deg F, Method B: 0 to 200 deg F
Standard TimeTime for 1 cubic foot of air at 60 deg F and 10 psig inlet pressure
Seal TypeO-ring seals on nozzle flange
Nozzle MaterialStainless Steel
ComponentsSonic flow nozzles, prover holder, accessories
Recommended Flow Points10 to 20%, ~50%, 80 to 100% of meter capacity
FunctionProvides precise gas flow measurement and calibration for meters
ApplicationsGas meter testing and calibration
Flow Rate250 to 6000 scfh
CompatibilityDesigned for 2 in critical flow prover holders

Values retain manufacturer model qualifications. Review Honeywell specifications ↗

Resources

Filter documents by type

Resources linked from the manufacturer’s page. Confirm the document revision and applicable model before installation or ordering.

Honeywell resource listing ↗

Part Number

Published part numbers

8 parts

Part NumberDescriptionEnquiry
50156297-H01DN50 PN16 HP , Assembly, M.SONICRequest quotation
50156297-L01DN50 PN16 LP , Assembly, M.SONICRequest quotation
50156297-L02DN80 PN16 LP , Assembly, M.SONICRequest quotation
50156297-L03DN100 PN16 LP , Assembly, M.SONICRequest quotation
50156297-M01DN50 PN16 MP , ASSEMBLY, M.SONICRequest quotation
52091P005SONIC NOZZLE (B)Request quotation
52091P007SONIC NOZZLE (D)Request quotation
52091P009SONIC NOZZLE (F)Request quotation
Manufacturer sources

https://process.honeywell.com/us/en/products/utilities/gas/meter-hardware-and-accessories/critical-flow-provers

Last source check: 2026-11-02

Critical Flow Provers image · Manufacturer ownership retained; republication licence not independently confirmed

ABID Automation LTD maintains this independent product reference. Honeywell owns its product names and trademarks. Current manufacturer documentation governs specification, availability and certification.

Your next project. A clear starting point.

Tell us about your facility and what you need to achieve.

CallSend enquiry