Safety Devices
S100 Slamshut Valve
S100 Slamshut protects gas installations by closing flow on overpressure.
S100 Slamshut protects gas installations by closing flow on overpressure. Its full-bore construction limits pressure loss and includes a visible trip indication. The manufacturer lists flanged sizes and an external sensing connection, with the selected spring determining the response setting. The actual protection assembly must match the downstream pressure and piping arrangement.
Models: S100 Slamshut Valve
Features & Benefits
- Sizes
- 2, 3 and 4 in flanged
- External sense
- ¼ in NPT
- Published setting range
- 7 in water column–87 psig
- Full-bore construction provides low pressure drop
Applications
- Gas installation overpressure shut-off
General Overview
- Applications
- Protects gas systems from overpressure; installed upstream of regulator
- Product Type
- Slam shut valve (safety shut-off device)
- Installation Orientation
- Suitable for vertical or horizontal pipework
- Compatible Gases
- Natural Gas, LPG, Manufactured Gases
Construction
- Valve Seat Material
- Stainless Steel
- Spring Material
- Carbon Steel Loaded Spring, Stainless Steel Wire Mechanism Spring
- Diaphragm/Seals Material
- Nitrile (Buna)
- Body Material
- Nodular Iron
Pressure Ratings
- Trip Pressure Range
- 6 bar (87 psig)
- Maximum Inlet Pressure
- 19 bar (275 psig)
Operating Conditions
- Temperature Range
- -20 to +60 deg C
Functionality
- Operating Principle
- Pressure sensing via impulse line; trips and shuts valve when pressure exceeds set value
- Indicators
- Visual valve position indicator
Connection Options
- Impulse Connection
- Rc 1/4 tapping
- Connection Type
- Flanged (BS EN 1092-2 NP16)
- Connection Size
- DN50, DN80, DN100
Control & Operation
- Control Type
- Spring‑loaded, pressure‑activated mechanism
Safety & Compliance
- Approvals
- BS EN 14382, BGES/V9, DIN 3381, PED 2014/68/EU (CE), UKCA (Category IV safety accessory)
| Parameter | Published value / configuration |
|---|---|
| Applications | Protects gas systems from overpressure; installed upstream of regulator |
| Product Type | Slam shut valve (safety shut-off device) |
| Installation Orientation | Suitable for vertical or horizontal pipework |
| Compatible Gases | Natural Gas, LPG, Manufactured Gases |
| Valve Seat Material | Stainless Steel |
| Spring Material | Carbon Steel Loaded Spring, Stainless Steel Wire Mechanism Spring |
| Diaphragm/Seals Material | Nitrile (Buna) |
| Body Material | Nodular Iron |
| Trip Pressure Range | 6 bar (87 psig) |
| Maximum Inlet Pressure | 19 bar (275 psig) |
| Temperature Range | -20 to +60 deg C |
| Operating Principle | Pressure sensing via impulse line; trips and shuts valve when pressure exceeds set value |
| Indicators | Visual valve position indicator |
| Impulse Connection | Rc 1/4 tapping |
| Connection Type | Flanged (BS EN 1092-2 NP16) |
| Connection Size | DN50, DN80, DN100 |
| Control Type | Spring‑loaded, pressure‑activated mechanism |
| Approvals | BS EN 14382, BGES/V9, DIN 3381, PED 2014/68/EU (CE), UKCA (Category IV safety accessory) |
Values retain manufacturer model qualifications. Review Honeywell specifications ↗
Part Number
Published model / variant identifiers. A full ordering code requires the manufacturer configuration.
Published part numbers
8 parts
| Part Number | Description | Enquiry |
|---|---|---|
| 73007626 | Adjusting ring SSV over set pr. >100mbar | Request quotation |
| 73008955 | SSV-spring 59-138 mbar white | Request quotation |
| 73008956 | SSV-spring 117-276 mbar light blue | Request quotation |
| 73008957 | SSV-spring 236-470 mbar cadmium yellow | Request quotation |
| 73011415 | Valveplate SSV, MR50 | Request quotation |
| J10012-005 | SPRING CLOSING 4" | Request quotation |
| S1VC09 | Seat disc assembly S100, 2" | Request quotation |
| SK209-02 | S/KIT,S200,50mm,HP | Request quotation |
Manufacturer sources
Last source check: 2026-11-02
S100 Slamshut Valve product image · Manufacturer ownership retained; republication licence not independently confirmed
ABID Automation LTD maintains this independent product reference. Honeywell owns its product names and trademarks. Current manufacturer documentation governs specification, availability and certification.