Smart Gas Meters
Absolute-ENCODER AE5
Absolute ENCODER AE5 reads all eight rollers of a mechanical diaphragm-meter index optically and transfers an absolute digital reading.
Absolute ENCODER AE5 reads all eight rollers of a mechanical diaphragm-meter index optically and transfers an absolute digital reading. Wired versions receive electrical energy from the M-bus master, while radio arrangements use a communication-module battery. This preserves the gas-powered measuring mechanism and allows communication modules to be added after meter installation.
Features & Benefits
- Reading
- Optical scan of 8 digit rollers
- Wired power
- M-bus master
- Radio power
- Battery in communication module
- Absolute digital reading avoids reliance on pulse transmission
Applications
- Smart reading of diaphragm gas meters
Detailed capabilities
Absolute-ENCODER AE5 — product role
Absolute ENCODER AE5 reads all eight rollers of a mechanical diaphragm-meter index optically and transfers an absolute digital reading. Wired versions receive electrical energy from the M-bus master, while radio arrangements use a communication-module battery. This preserves the gas-powered measuring mechanism and allows communication modules to be added after meter installation.
Absolute reading and replaceable communication
Eight index rollers are scanned optically and transferred as an absolute data word, while gas pressure continues to power the mechanical meter. Electrical energy is needed for readout: an M-bus master supplies wired operation and a module battery supplies radio. Plug-and-seal modules synchronize automatically and can be changed without reprogramming the metrology component.
Wired M-bus and required factory variant
ACM M-BUS WIRE supports standard M-bus or OMS. Standard use requires the AE5 factory Standard variant; OMS requires the Multi-Protocol variant, and the source explicitly says that OMS wired communication is not encrypted. The module uses IP54 protection, -25 to55°C ambient and a two-meter, two-core cable, with3mA supply corresponding to two M-bus loads.
SCR connection
ACM SCR WIRE connects compatible SCR receiving equipment using OMS-related OBIS identifiers. It requires the AE5 Multi-Protocol factory variant and is explicitly unencrypted. The source lists IP54, -25 to55°C, a two-meter two-core cable with ferrules and3mA SCR supply; it does not equate that wired link with encrypted radio.
ACM5.X radio behavior
The radio module is supplied programmed for the Multi-Protocol AE5 and sends encrypted one-way OMS Generation4 Security ProfileB/Mode7 data at868MHz. It transmits every five minutes but refreshes the meter reading every twenty. The source gives up to four hundred meters depending on environment, IP54, -25 to55°C and a nonreplaceable3.6V lithium battery with twenty-year calculated life.
Published radio data ambiguity
The radio power is printed as approximately7mW with14dBm in parentheses, which are not equivalent quantities. Both source figures are therefore treated as a manufacturer inconsistency rather than normalized into a new rating. The storage range is -30 to60°C and relative humidity0–85%, distinct from the ambient operating limits.
Operating Conditions
- Ambient Temperature Range
- -25 to +55 deg C
- Storage Temperature
- -30 to +60 deg C (via communication module spec)
- Enclosure Rating
- IP54
Communication
- Wireless Option
- 868 MHz Wireless M‑Bus (OMS Gen4, encrypted mode)
- Supported Protocols
- M‑Bus, M‑Bus/OMS, SCR, Wireless M‑Bus
- Interface Type
- Cable-based or wireless (via communication modules)
Variants & Options
- Protocol Options
- Multi-protocol (M‑Bus, OMS, SCR)
General Overview
- Product Type
- Electronic encoder index for diaphragm gas meters
- Primary Function
- Records gas volume and provides electronic readout
- Applications
- Residential, commercial, and industrial diaphragm gas meters (BK‑G..A, G1.6–G100)
Pressure & Mechanical
- Mechanical Link
- Magnetic coupling from diaphragm mechanism
- Maximum Operating Pressure
- 0.5 bar
- Fire Resistance
- Up to 0.1 bar (HTR)
Pressure & Measurement
- Measurement Type
- Volume at measurement conditions
Construction
- Housing Material
- Integrated into diaphragm gas meter (steel housing)
- Finish
- Powder-coated (RAL 7035 light grey)
Functionality
- Data Transfer
- Via communication modules to downstream receiving unit
- Data Output
- Absolute meter readings (non-resettable position encoding)
Measurement Principle
- Base Meter Type
- Diaphragm gas meter (pneumatic principle)
Safety & Compliance
- Approvals
- MID, EN 1359, DVGW, PTB approvals
| Parameter | Published value / configuration |
|---|---|
| Ambient Temperature Range | -25 to +55 deg C |
| Storage Temperature | -30 to +60 deg C (via communication module spec) |
| Enclosure Rating | IP54 |
| Wireless Option | 868 MHz Wireless M‑Bus (OMS Gen4, encrypted mode) |
| Supported Protocols | M‑Bus, M‑Bus/OMS, SCR, Wireless M‑Bus |
| Interface Type | Cable-based or wireless (via communication modules) |
| Protocol Options | Multi-protocol (M‑Bus, OMS, SCR) |
| Product Type | Electronic encoder index for diaphragm gas meters |
| Primary Function | Records gas volume and provides electronic readout |
| Applications | Residential, commercial, and industrial diaphragm gas meters (BK‑G..A, G1.6–G100) |
| Mechanical Link | Magnetic coupling from diaphragm mechanism |
| Maximum Operating Pressure | 0.5 bar |
| Fire Resistance | Up to 0.1 bar (HTR) |
| Measurement Type | Volume at measurement conditions |
| Housing Material | Integrated into diaphragm gas meter (steel housing) |
| Finish | Powder-coated (RAL 7035 light grey) |
| Data Transfer | Via communication modules to downstream receiving unit |
| Data Output | Absolute meter readings (non-resettable position encoding) |
| Base Meter Type | Diaphragm gas meter (pneumatic principle) |
| Approvals | MID, EN 1359, DVGW, PTB approvals |
Values retain manufacturer model qualifications. Review Honeywell specifications ↗
Part Number
Published part numbers
1 parts
| Part Number | Description | Enquiry |
|---|---|---|
| BU80001432 | BK-G4 V1,2 AE5.01 T A110 DN25 | Request quotation |
Manufacturer sources
Last source check: 2026-11-02
Absolute-ENCODER AE5 image · Manufacturer ownership retained; republication licence not independently confirmed
ABID Automation LTD maintains this independent product reference. Honeywell owns its product names and trademarks. Current manufacturer documentation governs specification, availability and certification.
Your next project. A clear starting point.
Tell us about your facility and what you need to achieve.