Residential Meters
ALPHA® 4 RES METER
ALPHA 4 Residential brings four-quadrant revenue measurement and continuous power-quality monitoring to residential endpoints.
ALPHA 4 Residential brings four-quadrant revenue measurement and continuous power-quality monitoring to residential endpoints. It records sag and swell events and maintains load and instrumentation profiles. Configurable tests can generate local warnings, dated logs or communication notifications, while an optical port and optional communication boards provide data access and network integration.
Models: ALPHA® 4 RES METER
Features & Benefits
- Power-quality tests
- 23 tests every 200 ms
- Interfaces
- Optical port and optional communication boards
- Integrated monitoring avoids separate option hardware for stated functions
Applications
- Residential electricity metering and service-condition monitoring
Detailed capabilities
ALPHA® 4 RES METER — product role
ALPHA 4 Residential brings four-quadrant revenue measurement and continuous power-quality monitoring to residential endpoints. It records sag and swell events and maintains load and instrumentation profiles. Configurable tests can generate local warnings, dated logs or communication notifications, while an optical port and optional communication boards provide data access and network integration.
Residential power-quality functions
A4Res runs twenty-three tests every two hundred milliseconds against user limits, independently from energy measurement. Voltage, current and distortion exceptions can generate display warnings, dated logs or push messages. Open-neutral alerts are specified for form2S services. Four-quadrant revenue measurement, sag/swell recording and profiles are included in the described platform.
Communication and protected history
The standard optical port can be supplemented by communication option boards. Motion and magnetic-tamper detection and ANSI C12.22 128-bit encrypted communication protect the arrangement. Event and history logs hold one thousand entries each, and the legally relevant parameter log applies from metrology version3.0 rather than all prior revisions.
Residential storage and profiling limits
A4Res provides eight megabytes of nonvolatile memory, forty self reads and 366 midnight snapshots. Up to twelve instrumentation channels record 79,200 one-minute intervals, corresponding to fifty-five days. More than fifty quantities can be selected, with independent minimum, maximum, average or interval-end storage choices where supported. These values differ from A4CI and must remain model-specific.
Compliance & Standards
- Accuracy
- ANSI C12.20 Class 0.5%
Operating Conditions
- Voltage Range
- 120 to 240 V (96 to 264 V operating)
- Temperature Range
- -40 to +85 deg C
- Power Consumption
- <1 W (meter only), up to 10 W with radios
- Humidity
- 0 to 100% non-condensing
- Frequency Range
- 50/60 Hz ±2%
Safety & Security
- Tamper Detection
- Magnetic tamper detection, motion detection
- Data Encryption
- AES‑128 bit encryption (ANSI C12.22)
- Alerts
- LCD warnings, logs, push notifications
Performance
- Self Reads
- Up to 40
- Memory
- 8 MB nonvolatile memory
- Interval Data Storage
- Instrumentation profiles + self-reads + snapshots; Up to 79,200 intervals (~55 days)
- Data Storage
- Extensive profile + logging capabilities
General Overview
- Product Type
- Smart electric revenue meter
- Platform
- Shared platform with Alpha 4 Commercial and Industrial (A4CI)
- Applications
- Residential smart grid metering
Control & Operation
- Processor
- ARM dual-core, 100 MHz, 32-bit CPU
- Optical Port
- Standard optical communication port
- Demand Control
- Block or rolling demand, calendar scheduling
Functionality
- Primary Function
- Measures and records electrical energy and demand
- Data Output
- Real-time energy, demand, and instrumentation data
Construction
- Form Factors
- 1S, 2S, 3S, 4S, 12S
Measurement & Data
- Energy Registers
- kWh, kVARh, kVAh (delivered, received, sum, net options)
- Demand Registers
- kW, kVAR, kVA (multiple programmable options)
- Bidirectional Metering
- Supported
Outage Management
- Clock Backup
- Up to 8 hours RTC during outage
Instrumentation Profiling
- Channels
- Up to 12 channels
Safety & Compliance
- Approvals
- ANSI C12.1, C12.10, C12.20, C12.21, C12.22
| Parameter | Published value / configuration |
|---|---|
| Accuracy | ANSI C12.20 Class 0.5% |
| Voltage Range | 120 to 240 V (96 to 264 V operating) |
| Temperature Range | -40 to +85 deg C |
| Power Consumption | <1 W (meter only), up to 10 W with radios |
| Humidity | 0 to 100% non-condensing |
| Frequency Range | 50/60 Hz ±2% |
| Tamper Detection | Magnetic tamper detection, motion detection |
| Data Encryption | AES‑128 bit encryption (ANSI C12.22) |
| Alerts | LCD warnings, logs, push notifications |
| Self Reads | Up to 40 |
| Memory | 8 MB nonvolatile memory |
| Interval Data Storage | Instrumentation profiles + self-reads + snapshots; Up to 79,200 intervals (~55 days) |
| Data Storage | Extensive profile + logging capabilities |
| Product Type | Smart electric revenue meter |
| Platform | Shared platform with Alpha 4 Commercial and Industrial (A4CI) |
| Applications | Residential smart grid metering |
| Processor | ARM dual-core, 100 MHz, 32-bit CPU |
| Optical Port | Standard optical communication port |
| Demand Control | Block or rolling demand, calendar scheduling |
| Primary Function | Measures and records electrical energy and demand |
| Data Output | Real-time energy, demand, and instrumentation data |
| Form Factors | 1S, 2S, 3S, 4S, 12S |
| Energy Registers | kWh, kVARh, kVAh (delivered, received, sum, net options) |
| Demand Registers | kW, kVAR, kVA (multiple programmable options) |
| Bidirectional Metering | Supported |
| Clock Backup | Up to 8 hours RTC during outage |
| Channels | Up to 12 channels |
| Approvals | ANSI C12.1, C12.10, C12.20, C12.21, C12.22 |
Values retain manufacturer model qualifications. Review Honeywell specifications ↗
Resources
Resources linked from the manufacturer’s page. Confirm the document revision and applicable model before installation or ordering.
Honeywell resource listing ↗Part Number
Published model / variant identifiers. A full ordering code requires the manufacturer configuration.
Published part numbers
3 parts
| Part Number | Description | Enquiry |
|---|---|---|
| 5D26218G01 | COVER WITH PORT PLATE | Request quotation |
| 5D26260G01 | A4 ELEC ASSY, RES, 8M, 2CT, SDS, OUTAGE | Request quotation |
| A4RES | HONEYWELL A4 RESIDENTIAL METER | Request quotation |
Manufacturer sources
Last source check: 2026-11-02
A4Res image · Manufacturer ownership retained; republication licence not independently confirmed
ABID Automation LTD maintains this independent product reference. Honeywell owns its product names and trademarks. Current manufacturer documentation governs specification, availability and certification.
Your next project. A clear starting point.