Fire & Life Safety · Building Systems · Industrial Automation [email protected] +880 1347 561 256
Honeywell Process Measurement & Control
Antisurge Product Image

Compressor Control

Antisurge Control

CCC Antisurge Control monitors compressor conditions and calculates how close operation is to the surge limit.

CCC Antisurge Control monitors compressor conditions and calculates how close operation is to the surge limit. It adjusts recycle or blow-off valves using coordinated closed- and open-loop responses, helping maintain protection while avoiding unnecessary recycle. The application serves centrifugal and axial compressors, where appropriate surge margins must be balanced against process stability, throughput and energy use.

Features & Benefits

Control
Recycle/blow-off valve modulation relative to surge limit
  • Supports compressor protection with less unnecessary recycle

Applications

  • Centrifugal and axial compressors

Detailed capabilities

Product and configuration

CCC Antisurge Control monitors compressor conditions and calculates how close operation is to the surge limit. It adjusts recycle or blow-off valves using coordinated closed- and open-loop responses, helping maintain protection while avoiding unnecessary recycle. The application serves centrifugal and axial compressors, where appropriate surge margins must be balanced against process stability, throughput and energy use.

  • Control: Recycle/blow-off valve modulation relative to surge limit

Manufacturer reference ↗

Operation and integration

The controller models the compressor surge limit and combines PI, derivative, Recycle Trip and Safety On responses to position the recycle or blow-off valve. It can transfer among a primary loop and up to three limiting loops, sequence loading/unloading and shutdown, account for changing gas composition and coordinate parallel/series machines with Performance Control. Published functions also cover recycle balancing, choke proximity, sidestream and variable-geometry arrangements.

Manufacturer reference ↗

Application and selection

The goal is to retain the stable compressor envelope with less unnecessary recycle or blow-off. Low suction or high discharge pressure can be handled through limiting control. Configuration ranges from single-stage air machines to complex refrigeration arrangements; these options need the appropriate compressor model, geometry, sequencing and companion applications rather than a universal default setup.

Manufacturer reference ↗

Case studies & further resources

Manufacturer Document

Replace Your Surge Detector with a Smart EAS3 | Brochure

View resource ↗

Resources

Filter documents by type

Resources linked from the manufacturer’s page. Confirm the document revision and applicable model before installation or ordering.

Honeywell resource listing ↗
Manufacturer sources

https://process.honeywell.com/us/en/products/turbomachinery-automation-systems/ccc-control-software/compressor-control/antisurge-control

Last source check: 2026-11-02

Antisurge Product Image · Manufacturer ownership retained; republication licence not independently confirmed

ABID Automation LTD maintains this independent product reference. Honeywell owns its product names and trademarks. Current manufacturer documentation governs specification, availability and certification.

Your next project. A clear starting point.

Tell us about your facility and what you need to achieve.

CallSend enquiry