Fire & Life Safety · Building Systems · Industrial Automation [email protected] +880 1347 561 256
Honeywell Process Measurement & Control

Pressure Regulators

Variable air/gas ratio controls GIKH

GIKH maintains an approximately 4:1 gas/air relationship in systems using preheated combustion air.

GIKH maintains an approximately 4:1 gas/air relationship in systems using preheated combustion air. It is a DN25 control with threaded or flanged connection options. Published inlet, outlet, air-control differential and maximum pressure-difference limits define the arrangement; it should not be substituted for a 1:1 ratio regulator without application review.

Features & Benefits

Gas Type
Town Gas, Natural Gas, LPG (gaseous), Biogas (max. 0.02% H2S) (GIKH..L for air only, must be clean and dry)
Storage Temperature Range
-20 to +40 deg C
Ambient Temperature Range
-20 to +60 deg C
Gas/Air Pressure Ratio
4:1
Maximum Pressure Drop
100 mbar
Connection Type
Rp Internal Thread (ISO 7-1), NPT Internal Thread
Nominal Sizes
Single Nominal Size (see datasheet for details)
Approvals
EU 2016/426 GAR; EN 88-1:2022 + A1:2023; Eurasian Customs Union Compliance
Material
Aluminum
DN
25
pu
max. 200 mbar
delta p
max. 100 mbar
delta psa
0.15 to 30 mbar
pd
0.2 to 120 mbar

Applications

  • Gas/air ratio control with preheated combustion air

Specifications

Fuel, Gas & Media Specifications

Gas Type
Town Gas, Natural Gas, LPG (gaseous), Biogas (max. 0.02% H2S) (GIKH..L for air only, must be clean and dry)

Storage/Transport Temperatures

Storage Temperature Range
-20 to +40 deg C

Environmental Conditions

Ambient Temperature Range
-20 to +60 deg C

Pressure Specifications

Gas/Air Pressure Ratio
4:1
Maximum Pressure Drop
100 mbar

Connections & Interfaces

Connection Type
Rp Internal Thread (ISO 7-1), NPT Internal Thread

Dimensions & Size Specifications

Nominal Sizes
Single Nominal Size (see datasheet for details)

Applications & Compatibility

Applications
Maintains constant gas/air pressure ratio and controls gas pressure in systems with recuperative air preheating; Used in iron, steel, glass, ceramics industries, and commercial heat generation (packaging, paper, foodstuffs)

Standards & Certifications

Approvals
EU 2016/426 GAR; EN 88-1:2022 + A1:2023; Eurasian Customs Union Compliance

Material Specifications

Material
Aluminum

Technical Specifications

DN
25
pu
max. 200 mbar
delta p
max. 100 mbar
delta psa
0.15 to 30 mbar
pd
0.2 to 120 mbar
Variable air/gas ratio controls GIKH — manufacturer page values
ParameterPublished value / configuration
Gas TypeTown Gas, Natural Gas, LPG (gaseous), Biogas (max. 0.02% H2S) (GIKH..L for air only, must be clean and dry)
Storage Temperature Range-20 to +40 deg C
Ambient Temperature Range-20 to +60 deg C
Gas/Air Pressure Ratio4:1
Maximum Pressure Drop100 mbar
Connection TypeRp Internal Thread (ISO 7-1), NPT Internal Thread
Nominal SizesSingle Nominal Size (see datasheet for details)
ApplicationsMaintains constant gas/air pressure ratio and controls gas pressure in systems with recuperative air preheating; Used in iron, steel, glass, ceramics industries, and commercial heat generation (packaging, paper, foodstuffs)
ApprovalsEU 2016/426 GAR; EN 88-1:2022 + A1:2023; Eurasian Customs Union Compliance
MaterialAluminum
DN25
pumax. 200 mbar
delta pmax. 100 mbar
delta psa0.15 to 30 mbar
pd0.2 to 120 mbar

Values retain manufacturer model qualifications. Review Honeywell specifications ↗

Manufacturer sources

https://process.honeywell.com/us/en/products/thermal-solutions/fuel-and-air-delivery/pressure-regulators/variable-air-gas-ratio-controls-gikh

Last source check: 2026-11-02

Variable air/gas ratio controls · Manufacturer ownership retained; republication licence not independently confirmed

ABID Automation LTD maintains this independent product reference. Honeywell owns its product names and trademarks. Current manufacturer documentation governs specification, availability and certification.

Your next project. A clear starting point.

Tell us about your facility and what you need to achieve.

CallSend enquiry