Eclipse standard train segments distinguish NFPA versions using the stated UL/CSA/FM-approved components from EN 746-2 versions using CE-marked components.
Eclipse standard train segments distinguish NFPA versions using the stated UL/CSA/FM-approved components from EN 746-2 versions using CE-marked components. Threaded or flanged arrangements depend on pipe size. Configured trains can add strainers, regulators and gauges; the source's component approval basis should not be generalized into an unrelated whole-system certification.
Features & Benefits
- Series
- Series CE, Series NFPA
- Maximum Assembly Pressure
- 4.7 PSI (33 kPa)
- Ambient Temperature Range
- +14 to +140°F (‑10 to +60°C)
- Fluid Temperature Range
- +5 to +140°F (‑15 to +60°C)
- Enclosure Rating
- NEMA 12/IP54
- Ambient Humidity
- 5 to 95% RH
- Supply Voltage
- 120V or 230V
- Process Media
- Clean Fuel Gas: Natural Gas (Methane), Propane, Butane
- Frequency
- 50 to 60 Hz
- Approvals
- Series CE - EN 746‑2 CE Approval|Series NFPA - NFPA 86‑2007, UL, FM, CSA
- Standardized segments reduce gas-train installation work.
Applications
- Industrial gas-train installation
Overview
- Series
- Series CE, Series NFPA
Pressure Specifications
- Maximum Assembly Pressure
- 4.7 PSI (33 kPa)
Environmental Conditions
- Ambient Temperature Range
- +14 to +140°F (‑10 to +60°C)
- Enclosure Rating
- NEMA 12/IP54
- Ambient Humidity
- 5 to 95% RH
Fluid/Media/Component Temperatures
- Fluid Temperature Range
- +5 to +140°F (‑15 to +60°C)
Electrical Specifications
- Supply Voltage
- 120V or 230V
- Frequency
- 50 to 60 Hz
Fuel, Gas & Media Specifications
- Process Media
- Clean Fuel Gas: Natural Gas (Methane), Propane, Butane
Applications & Compatibility
- Applications
- Assembly into complete gas valve trains with additional piping/components
Standards & Certifications
- Approvals
- Series CE - EN 746‑2 CE Approval; Series NFPA - NFPA 86‑2007, UL, FM, CSA
| Parameter | Published value / configuration |
|---|---|
| Series | Series CE, Series NFPA |
| Maximum Assembly Pressure | 4.7 PSI (33 kPa) |
| Ambient Temperature Range | +14 to +140°F (‑10 to +60°C) |
| Enclosure Rating | NEMA 12/IP54 |
| Ambient Humidity | 5 to 95% RH |
| Fluid Temperature Range | +5 to +140°F (‑15 to +60°C) |
| Supply Voltage | 120V or 230V |
| Frequency | 50 to 60 Hz |
| Process Media | Clean Fuel Gas: Natural Gas (Methane), Propane, Butane |
| Applications | Assembly into complete gas valve trains with additional piping/components |
| Approvals | Series CE - EN 746‑2 CE Approval; Series NFPA - NFPA 86‑2007, UL, FM, CSA |
Values retain manufacturer model qualifications. Review Honeywell specifications ↗
Part Number
Published part numbers
10 parts
| Part Number | Description | Enquiry |
|---|---|---|
| 10029408 | VLVTRN,GAS,SEG,NFPA,0.5 IN.,NPT,120V | Request quotation |
| 10029410 | VLVTRN,GAS,SEG,CE,0.5 IN.,BSP,120V | Request quotation |
| 10029412 | VLVTRN,GAS,SEG,NFPA,0.75 IN.,NPT,120V | Request quotation |
| 10029413 | VLVTRN,GAS,SEG,CE,0.75 IN.,BSP,120V | Request quotation |
| 10029414 | VLVTRN,GAS,SEG,NFPA,1.0 IN.,NPT,120V | Request quotation |
| 10029415 | VLVTRN,GAS,SEG,CE,1.0 IN.,BSP,120V | Request quotation |
| 10029416 | VLVTRN,GAS,SEG,NFPA,1.5 IN.,NPT,120V | Request quotation |
| 10029417 | VLVTRN,GAS,SEG,CE,1.5 IN.,BSP,120V | Request quotation |
| 10029418 | VLVTRN,GAS,SEG,NFPA,2.0 IN.,NPT,120V | Request quotation |
| 10029420 | VLVTRN,GAS,SEG,NFPA,2.5 IN.,NPT,120V | Request quotation |