MAXON combustion chambers and heater boxes are standard or custom assemblies shaped around the burner flame and process. Material choices and fast thermal response support different heating duties. The page also describes commissioning and after-sales technical support through the manufacturer's network, with common spare parts held at its offices.

Features & Benefits

Capacity
1 million to 70 million Btu/hr
Outer Shell Temperature
120 deg F
Temperature Rating
150 to 2000 deg F
Insulation Options
Ceramic fiber modules, blankets, insulating castable, double shell design
Control Features
Temperature Control, Flame Supervision, Pressure Switches, Shutoff Valves
Air Flow Range
1,000 to 300,000 CFM
Pressure Type
Negative (Pull-Thru) or Positive (Push-Thru)
Pressure Drop
1 to 2 in wc
Heater Type
Direct Fired Air Heater
Fuel Type
Natural Gas, Oil, Propane

Applications

  • Burner combustion chambers matched to the process

Specifications

Performance Specifications

Capacity
1 million to 70 million Btu/hr

Fluid/Media/Component Temperatures

Outer Shell Temperature
120 deg F

Temperature Control/Measurement

Temperature Rating
150 to 2000 deg F

Mechanical Design & Adjustment Characteristics

Insulation Options
Ceramic fiber modules, blankets, insulating castable, double shell design

Control, Logic & Functional Behavior

Control Features
Temperature Control, Flame Supervision, Pressure Switches, Shutoff Valves

Air & Combustion Air Specifications

Air Flow Range
1,000 to 300,000 CFM

Pressure Specifications

Pressure Type
Negative (Pull-Thru) or Positive (Push-Thru)
Pressure Drop
1 to 2 in wc

Applications & Compatibility

Applications
Drying, Preheating, Calcining, Distilling, Grinding

Mechanical & Hardware Characteristics

Heater Type
Direct Fired Air Heater

Fuel, Gas & Media Specifications

Fuel Type
Natural Gas, Oil, Propane
Air Ducts, Heaters, and Heater Boxes — manufacturer page values
ParameterPublished value / configuration
Capacity1 million to 70 million Btu/hr
Outer Shell Temperature120 deg F
Temperature Rating150 to 2000 deg F
Insulation OptionsCeramic fiber modules, blankets, insulating castable, double shell design
Control FeaturesTemperature Control, Flame Supervision, Pressure Switches, Shutoff Valves
Air Flow Range1,000 to 300,000 CFM
Pressure TypeNegative (Pull-Thru) or Positive (Push-Thru)
Pressure Drop1 to 2 in wc
ApplicationsDrying, Preheating, Calcining, Distilling, Grinding
Heater TypeDirect Fired Air Heater
Fuel TypeNatural Gas, Oil, Propane

Values retain manufacturer model qualifications. Review Honeywell specifications ↗

Part Number

Published part numbers

3 parts

Part NumberDescriptionEnquiry
50163353-452COMBUSTION CHAMBERRequest quotation
50163353-462COMBUSTION CHAMBER VP-II-150Request quotation
50163353-463COMBUSTION CHAMBER VP-II-150Request quotation
Manufacturer sources

https://process.honeywell.com/us/en/products/thermal-solutions/complete-combustion-solutions/air-heaters-ah/air-ducts-heaters-and-heater-boxes

Last source check: 2026-11-02

Air Heaters AH Product Image · Manufacturer ownership retained; republication licence not independently confirmed

Air Heaters AH Product Image 3 · Manufacturer ownership retained; republication licence not independently confirmed

Air Heaters AH Product Image 2 · Manufacturer ownership retained; republication licence not independently confirmed

Air Heaters AH Product Image 1 · Manufacturer ownership retained; republication licence not independently confirmed

ABID Automation LTD maintains this independent product reference. Honeywell owns its product names and trademarks. Current manufacturer documentation governs specification, availability and certification.

Your next project. A clear starting point.

Tell us about your facility and what you need to achieve.

CallSend enquiry