Honeywell Process Measurement & Control

Single Burners

Vortometric

Vortometric uses strong combustion-air swirl for stable high-output firing with gas or light/heavy oil.

Vortometric uses strong combustion-air swirl for stable high-output firing with gas or light/heavy oil. A vortex arrangement supports oil vaporization, and alloy or refractory versions address different duties. Horizontal firing is standard; vertical firing requires added gas-lance support. Packaged systems can include air supply, valve trains, controls and flame supervision.

Features & Benefits

Combustion Air Temperature Range
500 deg F
Maximum Combustor Temperature
HI: Up to 2200 deg F (1204 deg C)|MI: 1200 to 2200 deg F (depending on combustor type)
Main Gas Shut-Off Valve Train
Must comply with NFPA/EN; minimum two shut-off valves
Installation Orientation
Horizontal or vertical (including vertical down)
Gas Inlet Orientation
0 deg , 90 deg , 180 deg , 270 deg positions
Preheated Air Limits
Max 500 deg F; MI requires burner upsizing above 250 deg F
Pipe Connection Type
NPT, BSP; ANSI or DIN flange for sizes 16V and above
Combustion Principle
High‑swirl combustion air
Combustion Air Swirl
High swirl for stable flame, high turndown, low NOₓ and CO emissions
Turndown Capability
High turndown
Heat Input Range
1,760 to 61,500 kW
Air Inlet Design
Requires straight ducting; velocity variation ≤ ±20%
Number of Sizes
12 sizes per series
Capacity Range
6,000,000 to 210,000,000 BTU/h (1,760 to 61,500 kW)
Ignition Type
Raw gas pilot with spark rod
Burner Series
Vortometric
Flame Sensor
UV Scanner (standard); IR Scanner (for oil/high CO); Dual Scanners for steam atomized oil
Fuel Type
Natural Gas, Propane, Butane, Fuel Oil (#2, #6), Bio-gas, Hydrogen, Alcohol, etc.
Approvals
NFPA and EN compliance for safety systems|UL, FM, CSA, CGA, CE (for approved valves/switches)
  • High swirl stabilizes firing over the operating range.

Applications

  • High-output industrial gas/oil heating

Detailed capabilities

Swirl, liquid-fuel vaporization and mounting

Vortometric stabilizes its flame with high air swirl, while the vortex generator vaporizes oil to support clean combustion. Low excess air serves efficiency; higher excess air supports large process-air volumes. Alloy, air-cooled alloy and refractory versions serve different duties. Horizontal mounting is standard, with additional lance supports required for vertical firing. Complete train/blower/control packages are optional configurations.

Manufacturer reference ↗

Features and benefits

  • High swirl stabilizes firing over the operating range.

Manufacturer reference ↗

Published application context

  • High-output industrial gas/oil heating

Manufacturer reference ↗

Specifications

Overview

Models
MI (Medium Intensity), HI (High Intensity)

Combustion/Furnace/Chamber Temperatures

Combustion Air Temperature Range
500 deg F
Maximum Combustor Temperature
HI: Up to 2200 deg F (1204 deg C); MI: 1200 to 2200 deg F (depending on combustor type)

Actuation, Valve & Motion Control Specifications

Main Gas Shut-Off Valve Train
Must comply with NFPA/EN; minimum two shut-off valves

Installation & Mounting Specifications

Installation Orientation
Horizontal or vertical (including vertical down)

Combustion, Fuel & Mixing Sub‑Systems

Gas Inlet Orientation
0 deg , 90 deg , 180 deg , 270 deg positions

Air & Combustion Air Specifications

Preheated Air Limits
Max 500 deg F; MI requires burner upsizing above 250 deg F
Combustion Air Swirl
High swirl for stable flame, high turndown, low NOₓ and CO emissions
Air Inlet Design
Requires straight ducting; velocity variation ≤ ±20%

Connections & Interfaces

Pipe Connection Type
NPT, BSP; ANSI or DIN flange for sizes 16V and above

Combustion, Mixing & Fuel Dynamics

Combustion Principle
High‑swirl combustion air

Processing & Performance Metrics

Turndown Capability
High turndown
Capacity Range
6,000,000 to 210,000,000 BTU/h (1,760 to 61,500 kW)

Performance, Flow & Capacity

Heat Input Range
1,760 to 61,500 kW

Dimensions & Size Specifications

Number of Sizes
12 sizes per series

Ignition, Flame & Supervision Specifications

Ignition Type
Raw gas pilot with spark rod
Flame Sensor
UV Scanner (standard); IR Scanner (for oil/high CO); Dual Scanners for steam atomized oil

Product Design & Configuration

Burner Series
Vortometric

Applications & Compatibility

Applications
Dryers, Ovens, Kilns, Thermal Oxidizers, Boilers, Incinerators

Fuel, Gas & Media Specifications

Fuel Type
Natural Gas, Propane, Butane, Fuel Oil (#2, #6), Bio-gas, Hydrogen, Alcohol, etc.

Standards & Certifications

Approvals
NFPA and EN compliance for safety systems; UL, FM, CSA, CGA, CE (for approved valves/switches)
Vortometric — manufacturer page values
ParameterPublished value / configuration
ModelsMI (Medium Intensity), HI (High Intensity)
Combustion Air Temperature Range500 deg F
Maximum Combustor TemperatureHI: Up to 2200 deg F (1204 deg C); MI: 1200 to 2200 deg F (depending on combustor type)
Main Gas Shut-Off Valve TrainMust comply with NFPA/EN; minimum two shut-off valves
Installation OrientationHorizontal or vertical (including vertical down)
Gas Inlet Orientation0 deg , 90 deg , 180 deg , 270 deg positions
Preheated Air LimitsMax 500 deg F; MI requires burner upsizing above 250 deg F
Combustion Air SwirlHigh swirl for stable flame, high turndown, low NOₓ and CO emissions
Air Inlet DesignRequires straight ducting; velocity variation ≤ ±20%
Pipe Connection TypeNPT, BSP; ANSI or DIN flange for sizes 16V and above
Combustion PrincipleHigh‑swirl combustion air
Turndown CapabilityHigh turndown
Capacity Range6,000,000 to 210,000,000 BTU/h (1,760 to 61,500 kW)
Heat Input Range1,760 to 61,500 kW
Number of Sizes12 sizes per series
Ignition TypeRaw gas pilot with spark rod
Flame SensorUV Scanner (standard); IR Scanner (for oil/high CO); Dual Scanners for steam atomized oil
Burner SeriesVortometric
ApplicationsDryers, Ovens, Kilns, Thermal Oxidizers, Boilers, Incinerators
Fuel TypeNatural Gas, Propane, Butane, Fuel Oil (#2, #6), Bio-gas, Hydrogen, Alcohol, etc.
ApprovalsNFPA and EN compliance for safety systems; UL, FM, CSA, CGA, CE (for approved valves/switches)

Values retain manufacturer model qualifications. Review Honeywell specifications ↗

Part Number

Published part numbers

10 parts

Part NumberDescriptionEnquiry
00.4100152.16AH-SF 80 compl new generation Position IRequest quotation
00.4100511.26RAH 80 compl new generation Position IIRequest quotation
10027022NZL,LNC,OIL,VM,32VRequest quotation
10027023CONE,NOSE,LNC,OIL,VM,32VRequest quotation
10027082RING,ASY,INLT,LNC,OIL,VM,32V,36VRequest quotation
10027085ATMZR,LNC,OIL,VM,32V,CWRequest quotation
10035205BDY,TIP,NZL,OIL,VM,14VRequest quotation
10035206TIP,NZL,LNC,OIL,VM,14VRequest quotation
10035207BDY,TIP,NZL,OIL,VM,16VRequest quotation
10035208TIP,NZL,LNC,OIL,VM,16VRequest quotation
Manufacturer sources

https://process.honeywell.com/us/en/products/thermal-solutions/burners-and-heat-exchangers/single-burners/vortometric

Last source check: 2026-11-02

Vortometric Product Image · Manufacturer ownership retained; republication licence not independently confirmed

ABID Automation LTD maintains this independent product reference. Honeywell owns its product names and trademarks. Current manufacturer documentation governs specification, availability and certification.

Your next project. A clear starting point.

Tell us about your facility and what you need to achieve.

CallSend enquiry