Single Burners
VALUPAK®-II
VALUPAK-II is an all-metal packaged process-air burner with four size groups.
VALUPAK-II is an all-metal packaged process-air burner with four size groups. It supports UV or flame-rod supervision and includes a pilot-connection option. Switching between natural gas and propane provides fuel flexibility, while low gas-pressure requirements and multi-voltage/frequency blower choices support installation; the published capacity range uses HHV.
Features & Benefits
- Turndown Ratio
- High turndown (up to approximately 70:1 depending on model)
- Spark Ignitor Connection
- 1/2 in NPT
- Protection Class
- IP54
- Operating Pressure Range
- Balanced pressure (0 mbar duct pressure)
- Motor Voltage
- 230 to 480 V
- Motor Type
- Single‑phase (selected models), Triphase
- Installation Orientation
- Any orientation
- Ignition Type
- Direct Spark Ignition
- Heat Capacity Range
- 2 to 950 kW (LHV, size dependent)
- Gas Inlet Connection
- 1/2 to 1 in NPT (model dependent)
- Fuel Type
- Natural Gas (C1), LPG/Propane (C3)
- Frequency
- 50/60 Hz
- Emissions
- CO Emissions (NG) -< 25 to 50 mg/Nm³ at 17% O₂ (model dependent)|NOx Emissions (NG) - Typically 25 to 40 mg/Nm³ at 17% O₂
- Construction
- All‑metal
- Combustion Type
- Stable, clean combustion
- Burner Type
- Nozzle-mixing burner with packaged air blower
- Blower Types
- UHC102, UHC122, UHC142, UHC182, UHC202, UMI300, UMI390
- Approvals
- Eurasian Customs Union
- Gas/propane switching supports changes in fuel availability or cost.
Applications
- Process-air heating
Detailed capabilities
Fuel switching and blower selection
VALUPAK-II permits switching between natural gas and propane, with UV-scanner or flame-rod supervision and an available pilot connection. Four sizes cover the published HHV capacity range. All-metal construction, low gas-pressure demand and blower voltage/frequency choices adapt installation. Better CO control is a comparison with the legacy offering; it does not establish a single emissions value at every firing rate.
Features and benefits
- Gas/propane switching supports changes in fuel availability or cost.
Published application context
- Process-air heating
Applications & Compatibility
- Applications
- Process Air Heating, Textile Machines, Printing Machines, Dryers
Performance, Flow & Capacity
- Turndown Ratio
- High turndown (up to approximately 70:1 depending on model)
Connections & Interfaces
- Spark Ignitor Connection
- 1/2 in NPT
- Gas Inlet Connection
- 1/2 to 1 in NPT (model dependent)
Safety, Protection & Reliability
- Protection Class
- IP54
Pressure Specifications
- Operating Pressure Range
- Balanced pressure (0 mbar duct pressure)
Electrical Specifications
- Motor Voltage
- 230 to 480 V
- Frequency
- 50/60 Hz
Motor Specifications
- Motor Type
- Single‑phase (selected models), Triphase
Installation & Mounting Specifications
- Installation Orientation
- Any orientation
Ignition, Flame & Supervision Specifications
- Ignition Type
- Direct Spark Ignition
Performance Specifications
- Heat Capacity Range
- 2 to 950 kW (LHV, size dependent)
Fuel, Gas & Media Specifications
- Fuel Type
- Natural Gas (C1), LPG/Propane (C3)
Processing & Performance Metrics
- Emissions
- CO Emissions (NG) -< 25 to 50 mg/Nm³ at 17% O₂ (model dependent); NOx Emissions (NG) - Typically 25 to 40 mg/Nm³ at 17% O₂
Product Overview & Classification
- Construction
- All‑metal
Combustion Design & Characteristics
- Combustion Type
- Stable, clean combustion
Overview
- Burner Type
- Nozzle-mixing burner with packaged air blower
Combustion Air, Blower & Emissions Specifications
- Blower Types
- UHC102, UHC122, UHC142, UHC182, UHC202, UMI300, UMI390
Standards & Certifications
- Approvals
- Eurasian Customs Union
| Parameter | Published value / configuration |
|---|---|
| Applications | Process Air Heating, Textile Machines, Printing Machines, Dryers |
| Turndown Ratio | High turndown (up to approximately 70:1 depending on model) |
| Spark Ignitor Connection | 1/2 in NPT |
| Gas Inlet Connection | 1/2 to 1 in NPT (model dependent) |
| Protection Class | IP54 |
| Operating Pressure Range | Balanced pressure (0 mbar duct pressure) |
| Motor Voltage | 230 to 480 V |
| Frequency | 50/60 Hz |
| Motor Type | Single‑phase (selected models), Triphase |
| Installation Orientation | Any orientation |
| Ignition Type | Direct Spark Ignition |
| Heat Capacity Range | 2 to 950 kW (LHV, size dependent) |
| Fuel Type | Natural Gas (C1), LPG/Propane (C3) |
| Emissions | CO Emissions (NG) -< 25 to 50 mg/Nm³ at 17% O₂ (model dependent); NOx Emissions (NG) - Typically 25 to 40 mg/Nm³ at 17% O₂ |
| Construction | All‑metal |
| Combustion Type | Stable, clean combustion |
| Burner Type | Nozzle-mixing burner with packaged air blower |
| Blower Types | UHC102, UHC122, UHC142, UHC182, UHC202, UMI300, UMI390 |
| Approvals | Eurasian Customs Union |
Values retain manufacturer model qualifications. Review Honeywell specifications ↗
Part Number
Published part numbers
10 parts
| Part Number | Description | Enquiry |
|---|---|---|
| 306923 | VP II-150 Textile Package B. | Request quotation |
| 307149 | MIXING CONE VALUPAK II-60 | Request quotation |
| 307152 | VALUPAK II-60-UHC102-NG | Request quotation |
| 307153 | VALUPAK II-60-UHC122-NG+LPG | Request quotation |
| 307154 | VALUPAK II-60-UMI300-NG+LPG | Request quotation |
| 307155 | VALUPAK II-60-UHC102-LPG | Request quotation |
| 307911 | VAL II-150 EB & 150mm SLV | Request quotation |
| 307912 | VALUPAK II-300 EB | Request quotation |
| 307913 | VALUPAK II-600 EB | Request quotation |
| 307914 | VALUPAK II-900 EB | Request quotation |
Manufacturer sources
Last source check: 2026-11-02
VALUPAK®-II Product Image · Manufacturer ownership retained; republication licence not independently confirmed
ABID Automation LTD maintains this independent product reference. Honeywell owns its product names and trademarks. Current manufacturer documentation governs specification, availability and certification.
Your next project. A clear starting point.
Tell us about your facility and what you need to achieve.