Fire & Life Safety · Building Systems · Industrial Automation [email protected] +880 1347 561 256
Honeywell Process Measurement & Control

Single Burners

ThermAir

ThermAir supplies fixed combustion air through an integral blower while varying fuel over a broad range.

ThermAir supplies fixed combustion air through an integral blower while varying fuel over a broad range. Integrated orifices simplify adjustment, and the nozzle accepts natural gas, propane or butane without changing the nozzle. Published uses include textile ovens and moisture-removal heating, with rear service access and flexible piping orientation.

Features & Benefits

Control Motor Specifications
≤ 2 rpm, ≥ 25 in-lb torque, 90 deg stroke, Modulating control
Combustion Air Requirements
Fresh (20.9% O₂), clean, temperature ≤ 150 deg F (65 deg C)
Ignition Transformer Specs
6000 to 8000 VAC, ≥ 0.02 A, Full wave output
Installation Orientation
Vertical Down, Vertical Up, Horizontal
Valve Train Requirement
Main gas shut‑off valve train per NFPA recommendations
Pipe Connection Type
NPT or Rc Threaded
Limit Switch Options
High, low, high and low, or none
Combustion Principle
Nozzle‑mix combustion
Blower Configuration
Right-hand standard; left-hand optional
Primary Application
Direct and indirect air heating
Gas Control Options
Stripped, Basic (modulating valve), Complete (modulating valve + ratio regulator)
Combustor Materials
Alloy tube (low temp), SiC tube or refractory block (high temp)
Altitude Adjustment
Capacity reduced ~3% per 1000 ft (300 m) above sea level
Turndown Ratio
Greater than 30:1
Capacity Range
150,000 to 5,000,000 BTU/h (44 to 1465 kW)
Ignition Type
Direct Spark Ignition
Control Motor
Kromschröder IC 20 actuator or customer‑supplied motor
Burner Family
ThermAir®
Loading Line
Plastic, Flexible Braided Stainless Steel, Rigid Stainless Tube
Flame Sensor
Flame rod (TA0015 to TA0100), UV scanner (all models)
Burner Type
Nozzle‑mix air‑heating burner
Fuel Type
Multiple fuels (Natural Gas, Propane, Butane)
Low NOx emissions
60 ppm at high fire
  • One nozzle handles the three listed gases without changeover hardware.

Applications

  • Heaters
  • Textile ovens
  • Ovens requiring added moisture-carrying air

Detailed capabilities

Fixed-air firing and moisture removal

ThermAir holds combustion air fixed while fuel changes, making the integrated air/gas orifices useful during setup. The added air can carry moisture away in ovens, and the family handles the stated broad fuel-heating-value range. Natural gas, propane and butane use the same nozzle. Rear access, piping orientation and mixed metric/English interface options simplify installation without changing the published high-fire NOx reference.

Manufacturer reference ↗

Features and benefits

  • One nozzle handles the three listed gases without changeover hardware.

Manufacturer reference ↗

Published application context

  • Heaters
  • Textile ovens
  • Ovens requiring added moisture-carrying air

Manufacturer reference ↗

Technical facts in the product overview

  • Low NOx emissions: 60 ppm at high fire

Manufacturer reference ↗

Specifications

Overview

Models
TA0015 - TA0500
Burner Type
Nozzle‑mix air‑heating burner

Motor Specifications

Control Motor Specifications
≤ 2 rpm, ≥ 25 in-lb torque, 90 deg stroke, Modulating control
Control Motor
Kromschröder IC 20 actuator or customer‑supplied motor

Air & Combustion Air Specifications

Combustion Air Requirements
Fresh (20.9% O₂), clean, temperature ≤ 150 deg F (65 deg C)

Ignition, Flame & Supervision Specifications

Ignition Transformer Specs
6000 to 8000 VAC, ≥ 0.02 A, Full wave output
Ignition Type
Direct Spark Ignition
Flame Sensor
Flame rod (TA0015 to TA0100), UV scanner (all models)

Installation & Mounting Specifications

Installation Orientation
Vertical Down, Vertical Up, Horizontal

Actuation, Valve & Motion Control Specifications

Valve Train Requirement
Main gas shut‑off valve train per NFPA recommendations

Connections & Interfaces

Pipe Connection Type
NPT or Rc Threaded

Actuation, Control & Motion Characteristics

Limit Switch Options
High, low, high and low, or none

Combustion, Mixing & Fuel Dynamics

Combustion Principle
Nozzle‑mix combustion

Combustion Air, Blower & Emissions Specifications

Blower Configuration
Right-hand standard; left-hand optional

Applications & Compatibility

Primary Application
Direct and indirect air heating
Applications
Heaters, textile ovens, applications with highly variable fuel

Combustion, Fuel & Mixing Sub‑Systems

Gas Control Options
Stripped, Basic (modulating valve), Complete (modulating valve + ratio regulator)

Material Specifications

Combustor Materials
Alloy tube (low temp), SiC tube or refractory block (high temp)

Operating Limits, Durability & Lifecycle

Altitude Adjustment
Capacity reduced ~3% per 1000 ft (300 m) above sea level

Performance, Flow & Capacity

Turndown Ratio
Greater than 30:1

Processing & Performance Metrics

Capacity Range
150,000 to 5,000,000 BTU/h (44 to 1465 kW)

Product Design & Configuration

Burner Family
ThermAir®

Mechanical Design & Adjustment Characteristics

Loading Line
Plastic, Flexible Braided Stainless Steel, Rigid Stainless Tube

Fuel, Gas & Media Specifications

Fuel Type
Multiple fuels (Natural Gas, Propane, Butane)

Technical Specifications

Low NOx emissions
60 ppm at high fire
ThermAir — manufacturer page values
ParameterPublished value / configuration
ModelsTA0015 - TA0500
Burner TypeNozzle‑mix air‑heating burner
Control Motor Specifications≤ 2 rpm, ≥ 25 in-lb torque, 90 deg stroke, Modulating control
Control MotorKromschröder IC 20 actuator or customer‑supplied motor
Combustion Air RequirementsFresh (20.9% O₂), clean, temperature ≤ 150 deg F (65 deg C)
Ignition Transformer Specs6000 to 8000 VAC, ≥ 0.02 A, Full wave output
Ignition TypeDirect Spark Ignition
Flame SensorFlame rod (TA0015 to TA0100), UV scanner (all models)
Installation OrientationVertical Down, Vertical Up, Horizontal
Valve Train RequirementMain gas shut‑off valve train per NFPA recommendations
Pipe Connection TypeNPT or Rc Threaded
Limit Switch OptionsHigh, low, high and low, or none
Combustion PrincipleNozzle‑mix combustion
Blower ConfigurationRight-hand standard; left-hand optional
Primary ApplicationDirect and indirect air heating
ApplicationsHeaters, textile ovens, applications with highly variable fuel
Gas Control OptionsStripped, Basic (modulating valve), Complete (modulating valve + ratio regulator)
Combustor MaterialsAlloy tube (low temp), SiC tube or refractory block (high temp)
Altitude AdjustmentCapacity reduced ~3% per 1000 ft (300 m) above sea level
Turndown RatioGreater than 30:1
Capacity Range150,000 to 5,000,000 BTU/h (44 to 1465 kW)
Burner FamilyThermAir®
Loading LinePlastic, Flexible Braided Stainless Steel, Rigid Stainless Tube
Fuel TypeMultiple fuels (Natural Gas, Propane, Butane)
Low NOx emissions60 ppm at high fire

Values retain manufacturer model qualifications. Review Honeywell specifications ↗

Part Number

Published part numbers

10 parts

Part NumberDescriptionEnquiry
10053407-1KIT,LIT,TA,TA0015,ENGRequest quotation
10053407-2KIT,LIT,TA,TA0025,ENGRequest quotation
10053407-3KIT,LIT,TA,TA0040,ENGRequest quotation
10053407-4KIT,LIT,TA,TA0075,ENGRequest quotation
10053407-5KIT,LIT,TA,TA0100,ENGRequest quotation
10053407-5-DKIT,LIT,TA,TA0100,ENG,Request quotation
10053407-6KIT,LIT,TA,TA0200,ENGRequest quotation
10053407-7KIT,LIT,TA,TA0300,ENGRequest quotation
10053407-8KIT,LIT,TA,TA0400,ENGRequest quotation
10053407-9KIT,LIT,TA,TA0500,ENGRequest quotation
Manufacturer sources

https://process.honeywell.com/us/en/products/thermal-solutions/burners-and-heat-exchangers/single-burners/thermair

Last source check: 2026-11-02

Image · Manufacturer ownership retained; republication licence not independently confirmed

ThermAir Product Diagram · Manufacturer ownership retained; republication licence not independently confirmed

ABID Automation LTD maintains this independent product reference. Honeywell owns its product names and trademarks. Current manufacturer documentation governs specification, availability and certification.

Your next project. A clear starting point.

Tell us about your facility and what you need to achieve.

CallSend enquiry