Single Burners
ThermAir
ThermAir supplies fixed combustion air through an integral blower while varying fuel over a broad range.
ThermAir supplies fixed combustion air through an integral blower while varying fuel over a broad range. Integrated orifices simplify adjustment, and the nozzle accepts natural gas, propane or butane without changing the nozzle. Published uses include textile ovens and moisture-removal heating, with rear service access and flexible piping orientation.
Features & Benefits
- Control Motor Specifications
- ≤ 2 rpm, ≥ 25 in-lb torque, 90 deg stroke, Modulating control
- Combustion Air Requirements
- Fresh (20.9% O₂), clean, temperature ≤ 150 deg F (65 deg C)
- Ignition Transformer Specs
- 6000 to 8000 VAC, ≥ 0.02 A, Full wave output
- Installation Orientation
- Vertical Down, Vertical Up, Horizontal
- Valve Train Requirement
- Main gas shut‑off valve train per NFPA recommendations
- Pipe Connection Type
- NPT or Rc Threaded
- Limit Switch Options
- High, low, high and low, or none
- Combustion Principle
- Nozzle‑mix combustion
- Blower Configuration
- Right-hand standard; left-hand optional
- Primary Application
- Direct and indirect air heating
- Gas Control Options
- Stripped, Basic (modulating valve), Complete (modulating valve + ratio regulator)
- Combustor Materials
- Alloy tube (low temp), SiC tube or refractory block (high temp)
- Altitude Adjustment
- Capacity reduced ~3% per 1000 ft (300 m) above sea level
- Turndown Ratio
- Greater than 30:1
- Capacity Range
- 150,000 to 5,000,000 BTU/h (44 to 1465 kW)
- Ignition Type
- Direct Spark Ignition
- Control Motor
- Kromschröder IC 20 actuator or customer‑supplied motor
- Burner Family
- ThermAir®
- Loading Line
- Plastic, Flexible Braided Stainless Steel, Rigid Stainless Tube
- Flame Sensor
- Flame rod (TA0015 to TA0100), UV scanner (all models)
- Burner Type
- Nozzle‑mix air‑heating burner
- Fuel Type
- Multiple fuels (Natural Gas, Propane, Butane)
- Low NOx emissions
- 60 ppm at high fire
- One nozzle handles the three listed gases without changeover hardware.
Applications
- Heaters
- Textile ovens
- Ovens requiring added moisture-carrying air
Detailed capabilities
Fixed-air firing and moisture removal
ThermAir holds combustion air fixed while fuel changes, making the integrated air/gas orifices useful during setup. The added air can carry moisture away in ovens, and the family handles the stated broad fuel-heating-value range. Natural gas, propane and butane use the same nozzle. Rear access, piping orientation and mixed metric/English interface options simplify installation without changing the published high-fire NOx reference.
Features and benefits
- One nozzle handles the three listed gases without changeover hardware.
Published application context
- Heaters
- Textile ovens
- Ovens requiring added moisture-carrying air
Technical facts in the product overview
- Low NOx emissions: 60 ppm at high fire
Overview
- Models
- TA0015 - TA0500
- Burner Type
- Nozzle‑mix air‑heating burner
Motor Specifications
- Control Motor Specifications
- ≤ 2 rpm, ≥ 25 in-lb torque, 90 deg stroke, Modulating control
- Control Motor
- Kromschröder IC 20 actuator or customer‑supplied motor
Air & Combustion Air Specifications
- Combustion Air Requirements
- Fresh (20.9% O₂), clean, temperature ≤ 150 deg F (65 deg C)
Ignition, Flame & Supervision Specifications
- Ignition Transformer Specs
- 6000 to 8000 VAC, ≥ 0.02 A, Full wave output
- Ignition Type
- Direct Spark Ignition
- Flame Sensor
- Flame rod (TA0015 to TA0100), UV scanner (all models)
Installation & Mounting Specifications
- Installation Orientation
- Vertical Down, Vertical Up, Horizontal
Actuation, Valve & Motion Control Specifications
- Valve Train Requirement
- Main gas shut‑off valve train per NFPA recommendations
Connections & Interfaces
- Pipe Connection Type
- NPT or Rc Threaded
Actuation, Control & Motion Characteristics
- Limit Switch Options
- High, low, high and low, or none
Combustion, Mixing & Fuel Dynamics
- Combustion Principle
- Nozzle‑mix combustion
Combustion Air, Blower & Emissions Specifications
- Blower Configuration
- Right-hand standard; left-hand optional
Applications & Compatibility
- Primary Application
- Direct and indirect air heating
- Applications
- Heaters, textile ovens, applications with highly variable fuel
Combustion, Fuel & Mixing Sub‑Systems
- Gas Control Options
- Stripped, Basic (modulating valve), Complete (modulating valve + ratio regulator)
Material Specifications
- Combustor Materials
- Alloy tube (low temp), SiC tube or refractory block (high temp)
Operating Limits, Durability & Lifecycle
- Altitude Adjustment
- Capacity reduced ~3% per 1000 ft (300 m) above sea level
Performance, Flow & Capacity
- Turndown Ratio
- Greater than 30:1
Processing & Performance Metrics
- Capacity Range
- 150,000 to 5,000,000 BTU/h (44 to 1465 kW)
Product Design & Configuration
- Burner Family
- ThermAir®
Mechanical Design & Adjustment Characteristics
- Loading Line
- Plastic, Flexible Braided Stainless Steel, Rigid Stainless Tube
Fuel, Gas & Media Specifications
- Fuel Type
- Multiple fuels (Natural Gas, Propane, Butane)
Technical Specifications
- Low NOx emissions
- 60 ppm at high fire
| Parameter | Published value / configuration |
|---|---|
| Models | TA0015 - TA0500 |
| Burner Type | Nozzle‑mix air‑heating burner |
| Control Motor Specifications | ≤ 2 rpm, ≥ 25 in-lb torque, 90 deg stroke, Modulating control |
| Control Motor | Kromschröder IC 20 actuator or customer‑supplied motor |
| Combustion Air Requirements | Fresh (20.9% O₂), clean, temperature ≤ 150 deg F (65 deg C) |
| Ignition Transformer Specs | 6000 to 8000 VAC, ≥ 0.02 A, Full wave output |
| Ignition Type | Direct Spark Ignition |
| Flame Sensor | Flame rod (TA0015 to TA0100), UV scanner (all models) |
| Installation Orientation | Vertical Down, Vertical Up, Horizontal |
| Valve Train Requirement | Main gas shut‑off valve train per NFPA recommendations |
| Pipe Connection Type | NPT or Rc Threaded |
| Limit Switch Options | High, low, high and low, or none |
| Combustion Principle | Nozzle‑mix combustion |
| Blower Configuration | Right-hand standard; left-hand optional |
| Primary Application | Direct and indirect air heating |
| Applications | Heaters, textile ovens, applications with highly variable fuel |
| Gas Control Options | Stripped, Basic (modulating valve), Complete (modulating valve + ratio regulator) |
| Combustor Materials | Alloy tube (low temp), SiC tube or refractory block (high temp) |
| Altitude Adjustment | Capacity reduced ~3% per 1000 ft (300 m) above sea level |
| Turndown Ratio | Greater than 30:1 |
| Capacity Range | 150,000 to 5,000,000 BTU/h (44 to 1465 kW) |
| Burner Family | ThermAir® |
| Loading Line | Plastic, Flexible Braided Stainless Steel, Rigid Stainless Tube |
| Fuel Type | Multiple fuels (Natural Gas, Propane, Butane) |
| Low NOx emissions | 60 ppm at high fire |
Values retain manufacturer model qualifications. Review Honeywell specifications ↗
Part Number
Published part numbers
10 parts
| Part Number | Description | Enquiry |
|---|---|---|
| 10053407-1 | KIT,LIT,TA,TA0015,ENG | Request quotation |
| 10053407-2 | KIT,LIT,TA,TA0025,ENG | Request quotation |
| 10053407-3 | KIT,LIT,TA,TA0040,ENG | Request quotation |
| 10053407-4 | KIT,LIT,TA,TA0075,ENG | Request quotation |
| 10053407-5 | KIT,LIT,TA,TA0100,ENG | Request quotation |
| 10053407-5-D | KIT,LIT,TA,TA0100,ENG, | Request quotation |
| 10053407-6 | KIT,LIT,TA,TA0200,ENG | Request quotation |
| 10053407-7 | KIT,LIT,TA,TA0300,ENG | Request quotation |
| 10053407-8 | KIT,LIT,TA,TA0400,ENG | Request quotation |
| 10053407-9 | KIT,LIT,TA,TA0500,ENG | Request quotation |
Manufacturer sources
Last source check: 2026-11-02
Image · Manufacturer ownership retained; republication licence not independently confirmed
ThermAir Product Diagram · Manufacturer ownership retained; republication licence not independently confirmed
ABID Automation LTD maintains this independent product reference. Honeywell owns its product names and trademarks. Current manufacturer documentation governs specification, availability and certification.
Your next project. A clear starting point.
Tell us about your facility and what you need to achieve.