Fire & Life Safety · Building Systems · Industrial Automation [email protected] +880 1347 561 256
Honeywell Process Measurement & Control

Single Burners

RatioMatic

RatioMatic uses a pressure-ratio regulator that compensates for changing conditions without a second gas adjustment.

RatioMatic uses a pressure-ratio regulator that compensates for changing conditions without a second gas adjustment. A directly driven air butterfly avoids external linkage, while rapid nozzle mixing stabilizes the flame. The family spans several capacities, and its maximum turndown is explicitly dependent on burner size and chamber conditions.

Features & Benefits

Maximum Operating Temperature
1900 deg F (1040 deg C)
Control Motor Specifications
≤2 rpm, ≥25 in-lb torque, 90 deg stroke, reversible
Combustion Air Requirements
Fresh (20.9% O₂), clean, ≤150 deg F (65 deg C)
Valve Train Requirement
Main gas shut‑off valve train per NFPA recommendations
Excess Air Capability
10 to 15% at high fire|Higher at low fire
Air/Gas Ratio Control
Ratio regulator with impulse line
Gas Pipe Connections
Threaded Gas Connections (customer‑selected type)
Combustion Principle
Nozzle-mix, ratio-controlled combustion
Burner Configuration
Vertical Down, Vertical Up, Horizontal
Primary Application
Direct and indirect air heating; oven applications
Fuel Pressure Range
Must meet datasheet specs; low pressure may cause unsafe operation
Altitude Adjustment
Capacity reduced ~3% per 1000 ft above sea level
Flame Supervision
Flame rod (RM0050 to RM0700), UV scanner (all models)
Flame Monitoring
Individual or multiple burner control options
Hazard Warnings
Hot surfaces, combustion risks, crystalline silica exposure
Turndown Ratio
High‑turndown option available|Wide turndown
Combustor Tube
Alloy (low temp), SiC or refractory block (high temp)
Ignition Type
Direct Spark Ignition (low fire or bypass start gas)
Control Motor
Kromschröder IC 20 actuator or bracket for customer‑supplied motor
Burner Family
RatioMatic®
Burner Design
Modular design with various configurations
Loading Line
Plastic, Braided Stainless Steel, or Rigid Stainless Tube
Flame Sensor
Flame rod or UV scanner
Burner Type
Nozzle‑mix air‑heating burner
Fuel Type
Natural Gas, Propane, Butane
Approvals
NFPA Compliant (e.g., dual gas shut-off valves)
  • Automatic ratio compensation avoids a separate gas adjustment.
  • Direct drive removes a potentially slipping external linkage.

Applications

  • Process-air heating

Detailed capabilities

Pressure-ratio compensation and direct drive

RatioMatic's regulator automatically follows changing operating conditions, reducing the need to readjust a second gas setting. A directly driven butterfly controls combustion air without linkage that could slip or bind. Rapid fuel/air mixing retains a stable flame and releases heat into the chamber rather than concentrating it at the oven wall, supporting emission-sensitive air-heating processes.

Manufacturer reference ↗

Capacity and turndown belong to the installation

The published family covers 500,000–30,000,000 Btu/hr. Its stated maximum 90:1 turndown depends on burner size and chamber conditions; it is not a fixed value for every burner or every chamber. The source reports low NOx, CO and aldehydes but does not turn those general performance descriptions into one common emissions limit for all possible installations.

Manufacturer reference ↗

Features and benefits

  • Automatic ratio compensation avoids a separate gas adjustment.
  • Direct drive removes a potentially slipping external linkage.

Manufacturer reference ↗

Published application context

  • Process-air heating

Manufacturer reference ↗

Specifications

Overview

Models
RM0050 - RM3000
Burner Type
Nozzle‑mix air‑heating burner

Operating/Process Temperature Ranges

Maximum Operating Temperature
1900 deg F (1040 deg C)

Motor Specifications

Control Motor Specifications
≤2 rpm, ≥25 in-lb torque, 90 deg stroke, reversible
Control Motor
Kromschröder IC 20 actuator or bracket for customer‑supplied motor

Air & Combustion Air Specifications

Combustion Air Requirements
Fresh (20.9% O₂), clean, ≤150 deg F (65 deg C)
Excess Air Capability
10 to 15% at high fire; Higher at low fire
Air/Gas Ratio Control
Ratio regulator with impulse line

Actuation, Valve & Motion Control Specifications

Valve Train Requirement
Main gas shut‑off valve train per NFPA recommendations

Connections & Interfaces

Gas Pipe Connections
Threaded Gas Connections (customer‑selected type)

Combustion, Mixing & Fuel Dynamics

Combustion Principle
Nozzle-mix, ratio-controlled combustion

Combustion, Fuel & Mixing Sub‑Systems

Burner Configuration
Vertical Down, Vertical Up, Horizontal

Applications & Compatibility

Primary Application
Direct and indirect air heating; oven applications

Pressure Specifications

Fuel Pressure Range
Must meet datasheet specs; low pressure may cause unsafe operation

Operating Limits, Durability & Lifecycle

Altitude Adjustment
Capacity reduced ~3% per 1000 ft above sea level

Ignition, Flame & Supervision Specifications

Flame Supervision
Flame rod (RM0050 to RM0700), UV scanner (all models)
Flame Monitoring
Individual or multiple burner control options
Ignition Type
Direct Spark Ignition (low fire or bypass start gas)
Flame Sensor
Flame rod or UV scanner

Safety, Protection & Reliability

Hazard Warnings
Hot surfaces, combustion risks, crystalline silica exposure

Performance, Flow & Capacity

Turndown Ratio
High‑turndown option available; Wide turndown

Combustion Design & Characteristics

Combustor Tube
Alloy (low temp), SiC or refractory block (high temp)

Product Design & Configuration

Burner Family
RatioMatic®
Burner Design
Modular design with various configurations

Mechanical Design & Adjustment Characteristics

Loading Line
Plastic, Braided Stainless Steel, or Rigid Stainless Tube

Fuel, Gas & Media Specifications

Fuel Type
Natural Gas, Propane, Butane

Standards & Certifications

Approvals
NFPA Compliant (e.g., dual gas shut-off valves)
RatioMatic — manufacturer page values
ParameterPublished value / configuration
ModelsRM0050 - RM3000
Burner TypeNozzle‑mix air‑heating burner
Maximum Operating Temperature1900 deg F (1040 deg C)
Control Motor Specifications≤2 rpm, ≥25 in-lb torque, 90 deg stroke, reversible
Control MotorKromschröder IC 20 actuator or bracket for customer‑supplied motor
Combustion Air RequirementsFresh (20.9% O₂), clean, ≤150 deg F (65 deg C)
Excess Air Capability10 to 15% at high fire; Higher at low fire
Air/Gas Ratio ControlRatio regulator with impulse line
Valve Train RequirementMain gas shut‑off valve train per NFPA recommendations
Gas Pipe ConnectionsThreaded Gas Connections (customer‑selected type)
Combustion PrincipleNozzle-mix, ratio-controlled combustion
Burner ConfigurationVertical Down, Vertical Up, Horizontal
Primary ApplicationDirect and indirect air heating; oven applications
Fuel Pressure RangeMust meet datasheet specs; low pressure may cause unsafe operation
Altitude AdjustmentCapacity reduced ~3% per 1000 ft above sea level
Flame SupervisionFlame rod (RM0050 to RM0700), UV scanner (all models)
Flame MonitoringIndividual or multiple burner control options
Ignition TypeDirect Spark Ignition (low fire or bypass start gas)
Flame SensorFlame rod or UV scanner
Hazard WarningsHot surfaces, combustion risks, crystalline silica exposure
Turndown RatioHigh‑turndown option available; Wide turndown
Combustor TubeAlloy (low temp), SiC or refractory block (high temp)
Burner FamilyRatioMatic®
Burner DesignModular design with various configurations
Loading LinePlastic, Braided Stainless Steel, or Rigid Stainless Tube
Fuel TypeNatural Gas, Propane, Butane
ApprovalsNFPA Compliant (e.g., dual gas shut-off valves)

Values retain manufacturer model qualifications. Review Honeywell specifications ↗

Part Number

Published part numbers

10 parts

Part NumberDescriptionEnquiry
10020506NZL,MACHG,RM,RM0300,NATRequest quotation
10024135NZL,RM,RM0300,PROP/BUTANERequest quotation
10024136NZL,RM,RM0300,NATRequest quotation
10039113NZL,RM,200,NAT,TWO PC ASYRequest quotation
10039114NZL,RM,200,PROP/BUT,TWO PC ASYRequest quotation
10039141NZL,RM,500,NAT,TWO PC ASYRequest quotation
10039142NZL,RM,500,PROP/BUT,TWO PC ASYRequest quotation
10039143NZL,RM,700,NAT,TWO PC ASYRequest quotation
10039144NZL,RM,700,PROP/BUT,TWO PC ASYRequest quotation
10040035NZL,BRNR,RM400,V3,NAT,SS,WLDMNTRequest quotation
Manufacturer sources

https://process.honeywell.com/us/en/products/thermal-solutions/burners-and-heat-exchangers/single-burners/ratiomatic

Last source check: 2026-11-02

RatioMatic Product Image · Manufacturer ownership retained; republication licence not independently confirmed

RatioMatic Product Diagram · Manufacturer ownership retained; republication licence not independently confirmed

RatioMatic Flame Image · Manufacturer ownership retained; republication licence not independently confirmed

ABID Automation LTD maintains this independent product reference. Honeywell owns its product names and trademarks. Current manufacturer documentation governs specification, availability and certification.

Your next project. A clear starting point.

Tell us about your facility and what you need to achieve.

CallSend enquiry