Fire & Life Safety · Building Systems · Industrial Automation [email protected] +880 1347 561 256
Honeywell Process Measurement & Control

Single Burners

MEGAFIRE® HD

MEGAFIRE HD supports gas, No.

MEGAFIRE HD supports gas, No. 2 oil or simultaneous dual-fuel firing for kilns, dryers and process heaters. An inline-blower version includes its air supply, while an external-blower version addresses backpressure duties. Oil atomization uses steam or compressed air; published turndown differs between gas and oil configurations.

Features & Benefits

Combustion Air Preheat Capability
Up to 200 deg C (HD version)
Process Temperature Range
Upstream: 500 deg C, Downstream: 850 deg C (with HT refractory)
Flame Characteristics
Long, high‑momentum flame; oil flames longer and more radiant than gas flames
Maximum Heat Release
Up to 13,200 kW (13.2 MW)
Dual Fuel Capability
Can fire gas and oil simultaneously
Combustion Principle
Nozzle‑mix design with mixing cone and discharge sleeve
Orientation Options
EB version allows 22.5 deg increments|U (Up), D (Down), L (Left), R (Right)
Control System Type
External air/gas/oil control; compatible with MAXON MICRO-RATIO® and SMARTLINK®
Flame Supervision
UV Scanner (no flame rod)
Minimum Capacity
Gas Firing: As low as 250-500 kW, size‑dependent|Oil Firing: 500-1000 kW, size‑ and temperature‑dependent
Maximum Capacity
Gas Firing: 4,400 kW (15M‑HD), 8,800 kW (30M‑HD), 13,200 kW (45M‑HD)|Oil Firing: 4,000 kW (15M‑HD), 8,000 kW (30M‑HD), 12,000 kW (45M‑HD)
Burner Variant
HD - Heavy‑Duty
Ignition Type
Built-in pilot burner (gas standard, oil optional)
Burner Family
MEGAFIRE®
Burner Sizes
15M‑HD, 30M‑HD, 45M‑HD
Burner Type
Medium‑temperature, dual‑fuel nozzle‑mix burner
Fuel Type
Natural Gas, Propane, Butane, Biogas, Light Oil (#2), Kerosene
Material
Carbon Steel (1.0037)
  • Dual-fuel capability permits standby or alternate-fuel operation.

Applications

  • Kilns
  • Dryers
  • Process heaters

Detailed capabilities

Gas, oil and simultaneous firing

MEGAFIRE HD can burn natural gas or propane, No. 2 oil, or both at once. Oil atomization uses steam or compressed air, and the published turndown differs between gas and oil. Inline-blower packages include the air machine; external-blower versions address backpressure. Preassembled controls and trains are available, but nine styles/three sizes do not imply that every package includes all accessory options.

Manufacturer reference ↗

Features and benefits

  • Dual-fuel capability permits standby or alternate-fuel operation.

Manufacturer reference ↗

Published application context

  • Kilns
  • Dryers
  • Process heaters

Manufacturer reference ↗

Specifications

Air & Combustion Air Specifications

Combustion Air Preheat Capability
Up to 200 deg C (HD version)

Operating/Process Temperature Ranges

Process Temperature Range
Upstream: 500 deg C, Downstream: 850 deg C (with HT refractory)

Ignition, Flame & Supervision Specifications

Flame Characteristics
Long, high‑momentum flame; oil flames longer and more radiant than gas flames
Flame Supervision
UV Scanner (no flame rod)
Ignition Type
Built-in pilot burner (gas standard, oil optional)

Performance, Flow & Capacity

Maximum Heat Release
Up to 13,200 kW (13.2 MW)

Fuel, Gas & Media Specifications

Dual Fuel Capability
Can fire gas and oil simultaneously
Fuel Type
Natural Gas, Propane, Butane, Biogas, Light Oil (#2), Kerosene

Combustion, Mixing & Fuel Dynamics

Combustion Principle
Nozzle‑mix design with mixing cone and discharge sleeve

Mechanical Design & Hardware Details

Orientation Options
EB version allows 22.5 deg increments; U (Up), D (Down), L (Left), R (Right)

Control, Logic & Functional Behavior

Control System Type
External air/gas/oil control; compatible with MAXON MICRO-RATIO® and SMARTLINK®

Processing & Performance Metrics

Minimum Capacity
Gas Firing: As low as 250-500 kW, size‑dependent; Oil Firing: 500-1000 kW, size‑ and temperature‑dependent
Maximum Capacity
Gas Firing: 4,400 kW (15M‑HD), 8,800 kW (30M‑HD), 13,200 kW (45M‑HD); Oil Firing: 4,000 kW (15M‑HD), 8,000 kW (30M‑HD), 12,000 kW (45M‑HD)

Electrical Specifications

Burner Variant
HD - Heavy‑Duty

Product Design & Configuration

Burner Family
MEGAFIRE®

Dimensions & Size Specifications

Burner Sizes
15M‑HD, 30M‑HD, 45M‑HD

Applications & Compatibility

Applications
High‑capacity air heaters, paper machines (TADs), large industrial dryers, cement and sand dryers, fertilizer dehydrators, waste and fume incinerators, kilns

Overview

Burner Type
Medium‑temperature, dual‑fuel nozzle‑mix burner

Material Specifications

Material
Carbon Steel (1.0037)
MEGAFIRE® HD — manufacturer page values
ParameterPublished value / configuration
Combustion Air Preheat CapabilityUp to 200 deg C (HD version)
Process Temperature RangeUpstream: 500 deg C, Downstream: 850 deg C (with HT refractory)
Flame CharacteristicsLong, high‑momentum flame; oil flames longer and more radiant than gas flames
Flame SupervisionUV Scanner (no flame rod)
Ignition TypeBuilt-in pilot burner (gas standard, oil optional)
Maximum Heat ReleaseUp to 13,200 kW (13.2 MW)
Dual Fuel CapabilityCan fire gas and oil simultaneously
Fuel TypeNatural Gas, Propane, Butane, Biogas, Light Oil (#2), Kerosene
Combustion PrincipleNozzle‑mix design with mixing cone and discharge sleeve
Orientation OptionsEB version allows 22.5 deg increments; U (Up), D (Down), L (Left), R (Right)
Control System TypeExternal air/gas/oil control; compatible with MAXON MICRO-RATIO® and SMARTLINK®
Minimum CapacityGas Firing: As low as 250-500 kW, size‑dependent; Oil Firing: 500-1000 kW, size‑ and temperature‑dependent
Maximum CapacityGas Firing: 4,400 kW (15M‑HD), 8,800 kW (30M‑HD), 13,200 kW (45M‑HD); Oil Firing: 4,000 kW (15M‑HD), 8,000 kW (30M‑HD), 12,000 kW (45M‑HD)
Burner VariantHD - Heavy‑Duty
Burner FamilyMEGAFIRE®
Burner Sizes15M‑HD, 30M‑HD, 45M‑HD
ApplicationsHigh‑capacity air heaters, paper machines (TADs), large industrial dryers, cement and sand dryers, fertilizer dehydrators, waste and fume incinerators, kilns
Burner TypeMedium‑temperature, dual‑fuel nozzle‑mix burner
MaterialCarbon Steel (1.0037)

Values retain manufacturer model qualifications. Review Honeywell specifications ↗

Part Number

Published part numbers

10 parts

Part NumberDescriptionEnquiry
046379SHUTTER 30M MEGAFIRE IIRequest quotation
101018336GLND,PKG,14.25 MM OD,9.5 MM ID,7.95 MM TRequest quotation
1047565132" CTL CBLRequest quotation
1055544130" 45M MNFLD,DIS SLV GSKTRequest quotation
1095367SPL 15M AIR VLV W/SLVRequest quotation
1095368SPL 15M GAS TIP SI PLTRequest quotation
1095369MOD 15M MXG CONERequest quotation
111526215M AIR TBRequest quotation
112720045M EB TRNSTN SECT+Request quotation
15MHD15MBTURequest quotation
Manufacturer sources

https://process.honeywell.com/us/en/products/thermal-solutions/burners-and-heat-exchangers/single-burners/megafire-hd

Last source check: 2026-11-02

MEGAFIRE HD Industrial Burner · Manufacturer ownership retained; republication licence not independently confirmed

ABID Automation LTD maintains this independent product reference. Honeywell owns its product names and trademarks. Current manufacturer documentation governs specification, availability and certification.

Your next project. A clear starting point.

Tell us about your facility and what you need to achieve.