Fire & Life Safety · Building Systems · Industrial Automation [email protected] +880 1347 561 256
Honeywell Process Measurement & Control

Single Burners

KINEDIZER® Staged LE

KINEDIZER Staged LE combines staged nozzle mixing with medium-velocity discharge for direct high-temperature processes.

KINEDIZER Staged LE combines staged nozzle mixing with medium-velocity discharge for direct high-temperature processes. Fuel/air ratio control can use SMARTLINK or SLATE, and the page states a possible 80% hydrogen mixture by volume. Indirect service above the published heat-flux threshold requires separate consideration and catalog values.

Features & Benefits

Process Back Pressure Range
-40 to +40 in WC (-100 to +100 mbar)
Combustion Air Oxygen Range
21% O₂ (standard combustion air)
Process Temperature Range
Ambient to 2000 deg F (1100 deg C)
Installation Orientation
Suitable for direct‑fired high‑temperature applications
Cross Velocity Tolerance
Up to 3000 ft/min (15 m/s)
Combustion Air Source
External blower
Emissions Capability
NOₓ < 20 ppm at 3% O₂ with 20% excess air; low CO with proper dwell time
Combustion Principle
Nozzle‑mix, medium‑velocity burner with staged fuel delivery
Flame Supervision
UV Scanner (up to 3 positions)
Control Options
Designed for SmartLink®, Slate®, or equivalent fuel‑air ratio control systems
Turndown Ratio
Up to 20:1 (10:1 for high heat density)
Capacity Range
2.5, 5, and 10 MMBtu/h (≈660, 1322, 2667 kW)
CO Performance
Low CO achievable with sufficient post‑flame dwell time
Ignition Type
Direct spark or pilot
Burner Family
KINEDIZER® Staged LE
Burner Sizes
030, 040, 060 KDZERLES
Burner Type
High‑capacity staged low‑NOx gas burner
Fuel Type
Natural Gas (standard), Propane/LPG on special versions
Material
Carbon‑Steel Body, Refractory Block; 304SS/310SS Nozzle and Staging Components
  • Staged firing reduces NOx and excess-air demand relative to the cited LE design.

Applications

  • Thermal oxidizers
  • Helical-coil fluid heaters
  • Direct high-temperature processes

Detailed capabilities

Staging, modulation and hydrogen mixture

KINEDIZER Staged LE retains nozzle mixing and medium-velocity discharge while targeting less excess air and lower NOx than the cited KINEDIZER LE arrangement. Fuel and air can be positioned through controls such as SMARTLINK or SLATE with an external combustion-air supply. The source states that an 80% hydrogen mixture by volume is possible; this must remain a configuration-specific capability rather than a qualification for every KINEDIZER product.

Manufacturer reference ↗

Direct and indirect application limits

Primary duties include thermal oxidizers, helical-coil fluid heaters and other high-temperature direct processes. Their chamber environments differ, so the burner is engineered around the actual application. Indirect use above 7000 Btu/hr/in² requires special consideration and separate catalog figures. The reinforced refractory block and steel burner/nozzle structure support industrial service, but they do not remove that heat-flux qualification.

Manufacturer reference ↗

Features and benefits

  • Staged firing reduces NOx and excess-air demand relative to the cited LE design.

Manufacturer reference ↗

Published application context

  • Thermal oxidizers
  • Helical-coil fluid heaters
  • Direct high-temperature processes

Manufacturer reference ↗

Specifications

Pressure Specifications

Process Back Pressure Range
-40 to +40 in WC (-100 to +100 mbar)

Air & Combustion Air Specifications

Combustion Air Oxygen Range
21% O₂ (standard combustion air)
Combustion Air Source
External blower

Operating/Process Temperature Ranges

Process Temperature Range
Ambient to 2000 deg F (1100 deg C)

Installation & Mounting Specifications

Installation Orientation
Suitable for direct‑fired high‑temperature applications

Processing & Performance Metrics

Cross Velocity Tolerance
Up to 3000 ft/min (15 m/s)
Emissions Capability
NOₓ < 20 ppm at 3% O₂ with 20% excess air; low CO with proper dwell time
Capacity Range
2.5, 5, and 10 MMBtu/h (≈660, 1322, 2667 kW)
CO Performance
Low CO achievable with sufficient post‑flame dwell time

Combustion, Mixing & Fuel Dynamics

Combustion Principle
Nozzle‑mix, medium‑velocity burner with staged fuel delivery

Ignition, Flame & Supervision Specifications

Flame Supervision
UV Scanner (up to 3 positions)
Ignition Type
Direct spark or pilot

Control, Logic & Functional Behavior

Control Options
Designed for SmartLink®, Slate®, or equivalent fuel‑air ratio control systems

Performance, Flow & Capacity

Turndown Ratio
Up to 20:1 (10:1 for high heat density)

Product Design & Configuration

Burner Family
KINEDIZER® Staged LE

Dimensions & Size Specifications

Burner Sizes
030, 040, 060 KDZERLES

Applications & Compatibility

Applications
Thermal Oxidizers, Helical‑Coil Fluid Heaters, Kilns, Furnaces, Dryers, Waste Incineration

Overview

Burner Type
High‑capacity staged low‑NOx gas burner

Fuel, Gas & Media Specifications

Fuel Type
Natural Gas (standard), Propane/LPG on special versions

Material Specifications

Material
Carbon‑Steel Body, Refractory Block; 304SS/310SS Nozzle and Staging Components
KINEDIZER® Staged LE — manufacturer page values
ParameterPublished value / configuration
Process Back Pressure Range-40 to +40 in WC (-100 to +100 mbar)
Combustion Air Oxygen Range21% O₂ (standard combustion air)
Combustion Air SourceExternal blower
Process Temperature RangeAmbient to 2000 deg F (1100 deg C)
Installation OrientationSuitable for direct‑fired high‑temperature applications
Cross Velocity ToleranceUp to 3000 ft/min (15 m/s)
Emissions CapabilityNOₓ < 20 ppm at 3% O₂ with 20% excess air; low CO with proper dwell time
Capacity Range2.5, 5, and 10 MMBtu/h (≈660, 1322, 2667 kW)
CO PerformanceLow CO achievable with sufficient post‑flame dwell time
Combustion PrincipleNozzle‑mix, medium‑velocity burner with staged fuel delivery
Flame SupervisionUV Scanner (up to 3 positions)
Ignition TypeDirect spark or pilot
Control OptionsDesigned for SmartLink®, Slate®, or equivalent fuel‑air ratio control systems
Turndown RatioUp to 20:1 (10:1 for high heat density)
Burner FamilyKINEDIZER® Staged LE
Burner Sizes030, 040, 060 KDZERLES
ApplicationsThermal Oxidizers, Helical‑Coil Fluid Heaters, Kilns, Furnaces, Dryers, Waste Incineration
Burner TypeHigh‑capacity staged low‑NOx gas burner
Fuel TypeNatural Gas (standard), Propane/LPG on special versions
MaterialCarbon‑Steel Body, Refractory Block; 304SS/310SS Nozzle and Staging Components

Values retain manufacturer model qualifications. Review Honeywell specifications ↗

Part Number

Published part numbers

10 parts

Part NumberDescriptionEnquiry
030KDZERLES2.5 MBtu/h Staged KinedizerRequest quotation
040KDZERLES5.0 MBtu/h Staged KinedizerRequest quotation
060KDZERLES10.0 MBtu/h Staged KinedizerRequest quotation
080KDZERLES15.0 MBtu/h Staged KinedizerRequest quotation
50193837-001BLOCK, W/SLEEVE, 060 KDLE-SRequest quotation
50193839-001GASKET, BLOCK, 060 KDLE-SRequest quotation
50193848-001IGNITOR, SELF-GROUND, 127mm, 0.25in.NPTRequest quotation
50194022-001O-RING, VITON, SIZE 331Request quotation
50194023-001O-RING, VITON, SIZE 337Request quotation
50197870-001BLOCK, 080KDZERLESRequest quotation
Manufacturer sources

https://process.honeywell.com/us/en/products/thermal-solutions/burners-and-heat-exchangers/single-burners/kinedizer-staged-le

Last source check: 2026-11-02

KINEDIZER® Staged LE Product Image · Manufacturer ownership retained; republication licence not independently confirmed

KINEDIZER® Staged LE Secondary Image · Manufacturer ownership retained; republication licence not independently confirmed

KINEDIZER® Staged LE Secondary Image 2 · Manufacturer ownership retained; republication licence not independently confirmed

ABID Automation LTD maintains this independent product reference. Honeywell owns its product names and trademarks. Current manufacturer documentation governs specification, availability and certification.

Your next project. A clear starting point.

Tell us about your facility and what you need to achieve.

CallSend enquiry