Fire & Life Safety · Building Systems · Industrial Automation [email protected] +880 1347 561 256
Honeywell Process Measurement & Control

Immersion Tube Burners

TUBE-O-THERM®

TUBE-O-THERM fires directly into small-bore immersion tubes using natural gas, propane or butane.

TUBE-O-THERM fires directly into small-bore immersion tubes using natural gas, propane or butane. The package supports even tube heating with integral low-power or external-blower arrangements and wall-mounted service access. Flame-scanner capability covers the listed sizes, and the system does not require a powered exhaust under the published arrangement.

Features & Benefits

Version
Packaged burner; EB (external blower) burner
Tube Diameter Compatibility
3, 4, 6, 8,10 in
Maximum Heat Release
Up to 8,500,000 Btu/hr
Primary Application
Fires directly into small‑bore immersion tubes
Flame Supervision
Flame scanner capability available for all sizes
Combustion Method
Burner‑to‑tube direct firing system
Mounting Types
Wall‑mounted design
Product Type
Low temperature gas burner
Burner Type
Nozzle‑mixing, gas‑fired, refractory‑less
Fuel Type
Natural Gas; Propane; Butane; LPG blends
  • Direct small-bore firing improves heat distribution along the tube.
  • A separate powered exhaust is unnecessary in the described arrangement.

Applications

  • Industrial washers
  • Dip tanks
  • Water-bath heaters
  • Solution tanks

Detailed capabilities

Small-bore direct firing and air-supply choice

TUBE-O-THERM couples the burner directly to the immersion tube, reducing hot spots and distributing heat. A low-power blower can be integral, with external-blower models available. The wall-mounted arrangement gives service access, and flame-scanner capability is described across the sizes. The source lists both a model count and several tube diameters; those entries should remain visible rather than forcing an inferred one-to-one model/diameter matrix.

Manufacturer reference ↗

Features and benefits

  • Direct small-bore firing improves heat distribution along the tube.
  • A separate powered exhaust is unnecessary in the described arrangement.

Manufacturer reference ↗

Published application context

  • Industrial washers
  • Dip tanks
  • Water-bath heaters
  • Solution tanks

Manufacturer reference ↗

Specifications

Product Overview & Classification

Version
Packaged burner; EB (external blower) burner

Component/Geometry Compatibility

Tube Diameter Compatibility
3, 4, 6, 8,10 in

Applications & Compatibility

Typical Applications
Dip Tanks, Glycol Reboilers, Spray Washers, Pickling Tanks, Quench Tanks, Salt Baths, Indirect Air Heaters (With Proper Design), Bakery Ovens (With Proper Design)
Primary Application
Fires directly into small‑bore immersion tubes

Performance, Flow & Capacity

Maximum Heat Release
Up to 8,500,000 Btu/hr

Ignition, Flame & Supervision Specifications

Flame Supervision
Flame scanner capability available for all sizes

Combustion Design & Characteristics

Combustion Method
Burner‑to‑tube direct firing system

Installation & Mounting Specifications

Mounting Types
Wall‑mounted design

Overview

Product Type
Low temperature gas burner
Burner Type
Nozzle‑mixing, gas‑fired, refractory‑less

Fuel, Gas & Media Specifications

Fuel Type
Natural Gas; Propane; Butane; LPG blends
TUBE-O-THERM® — manufacturer page values
ParameterPublished value / configuration
VersionPackaged burner; EB (external blower) burner
Tube Diameter Compatibility3, 4, 6, 8,10 in
Typical ApplicationsDip Tanks, Glycol Reboilers, Spray Washers, Pickling Tanks, Quench Tanks, Salt Baths, Indirect Air Heaters (With Proper Design), Bakery Ovens (With Proper Design)
Primary ApplicationFires directly into small‑bore immersion tubes
Maximum Heat ReleaseUp to 8,500,000 Btu/hr
Flame SupervisionFlame scanner capability available for all sizes
Combustion MethodBurner‑to‑tube direct firing system
Mounting TypesWall‑mounted design
Product TypeLow temperature gas burner
Burner TypeNozzle‑mixing, gas‑fired, refractory‑less
Fuel TypeNatural Gas; Propane; Butane; LPG blends

Values retain manufacturer model qualifications. Review Honeywell specifications ↗

Part Number

Published part numbers

10 parts

Part NumberDescriptionEnquiry
10360466" FLG MAIN HSG ASY L/GSKT,+Request quotation
1044713MOD AIR INLT HSGRequest quotation
1049002TUBE-O-THERM SW ACT CAMRequest quotation
10522076-8 TOT MTR CONN RODRequest quotation
10596348" HC EB CONN ROD ASYRequest quotation
10596438" HC TRNSTN SLVRequest quotation
10596448" HC GAS NZLRequest quotation
10596458" HC AIR PLTRequest quotation
10598988" HC PERF PLTRequest quotation
10624368" HC CONN RODRequest quotation
Manufacturer sources

https://process.honeywell.com/us/en/products/thermal-solutions/burners-and-heat-exchangers/immersion-tube-burners/tube-o-therm

Last source check: 2026-11-02

TUBE-O-THERM® · Manufacturer ownership retained; republication licence not independently confirmed

ABID Automation LTD maintains this independent product reference. Honeywell owns its product names and trademarks. Current manufacturer documentation governs specification, availability and certification.

Your next project. A clear starting point.

Tell us about your facility and what you need to achieve.

CallSend enquiry