Fire & Life Safety · Building Systems · Industrial Automation [email protected] +880 1347 561 256
Honeywell Process Measurement & Control

Ignition Components

Q624 Ignition Transformer

Q624 is an interrupted-ignition transformer for gas pilots, with a published 15,000 V peak output and spark gaps up to 1/4 inch.

Q624 is an interrupted-ignition transformer for gas pilots, with a published 15,000 V peak output and spark gaps up to 1/4 inch. It fits conventional transformer space while reducing weight. Correct use with the listed MiniPeeper UV sensors prevents the detector from treating the ignition spark as a flame.

Features & Benefits

Ambient Temperature Range
-40 to +125°F (-40 to +52°C)
Maximum Lead Length
15 ft (4.6 m) High Voltage
Primary VA Rating
66 VA at 120 VAC
Power Dissipation
~12 watts per second
Energy Discharge
200 millijoules per spark
Ambient Humidity
95% RH
Output Voltage
15,000 V peak (firing cycle), 22,000 V peak-to-peak (nonsinusoidal)
Mounting Types
Surface mount
Discharge Time
0.3 milliseconds per spark
Firing Rate
60 sparks per second
Spark Gap
Up to 1/4 in (6 mm)
Frequency
50/60 Hz
Temperature Range
-40 to +125°F
Approximate, Dimensions
6 3/4 in. high x 4 1/4 in. wide x 3 in. deep (171.5 mm high x 108 mm wide x 76 mm deep)
Weight lb. (kg)
3 lb (1.4 kg)
Approvals, Underwriters Laboratories Inc.
Component Recognized Approvals, CSA: Certified: File No. LR95329
Operating Humidity Range (% RH)
95% RH
  • Lower weight simplifies replacement in conventional transformer space.

Applications

  • Interrupted gas-pilot ignition

Detailed capabilities

Ignition duty and flame-detector interaction

Q624 is limited to interrupted ignition, with its peak output intended for the stated gas-pilot gap. Correct installation with C7027/C7035/C7044 avoids falsely detecting the spark. The mounting envelope matches conventional transformers while reducing weight. Temperature, humidity and approval facts belong to the specified transformer; they do not authorize continuous ignition or a larger electrode spacing than the published limit.

Manufacturer reference ↗

Features and benefits

  • Lower weight simplifies replacement in conventional transformer space.

Manufacturer reference ↗

Published application context

  • Interrupted gas-pilot ignition

Manufacturer reference ↗

Technical facts in the product overview

  • Temperature Range: -40 to +125°F
  • Approximate, Dimensions: 6 3/4 in. high x 4 1/4 in. wide x 3 in. deep (171.5 mm high x 108 mm wide x 76 mm deep)
  • Weight lb. (kg): 3 lb (1.4 kg)
  • Approvals, Underwriters Laboratories Inc.: Component Recognized Approvals, CSA: Certified: File No. LR95329
  • Operating Humidity Range (% RH): 95% RH

Manufacturer reference ↗

Specifications

Environmental Conditions

Ambient Temperature Range
-40 to +125°F (-40 to +52°C)
Ambient Humidity
95% RH

Dimensions & Length Specifications

Maximum Lead Length
15 ft (4.6 m) High Voltage

Electrical Specifications

Primary VA Rating
66 VA at 120 VAC
Power Dissipation
~12 watts per second
Output Voltage
15,000 V peak (firing cycle), 22,000 V peak-to-peak (nonsinusoidal)
Frequency
50/60 Hz

Actuation, Valve & Motion Control Specifications

Energy Discharge
200 millijoules per spark
Discharge Time
0.3 milliseconds per spark

Installation & Mounting Specifications

Mounting Types
Surface mount

Applications & Compatibility

Applications
Ignites gas pilots on commercial or industrial gas burners; not recommended for oil ignition

Ignition, Flame & Supervision Specifications

Firing Rate
60 sparks per second
Spark Gap
Up to 1/4 in (6 mm)

Technical Specifications

Temperature Range
-40 to +125°F
Approximate, Dimensions
6 3/4 in. high x 4 1/4 in. wide x 3 in. deep (171.5 mm high x 108 mm wide x 76 mm deep)
Weight lb. (kg)
3 lb (1.4 kg)
Approvals, Underwriters Laboratories Inc.
Component Recognized Approvals, CSA: Certified: File No. LR95329
Operating Humidity Range (% RH)
95% RH
Q624 Ignition Transformer — manufacturer page values
ParameterPublished value / configuration
Ambient Temperature Range-40 to +125°F (-40 to +52°C)
Ambient Humidity95% RH
Maximum Lead Length15 ft (4.6 m) High Voltage
Primary VA Rating66 VA at 120 VAC
Power Dissipation~12 watts per second
Output Voltage15,000 V peak (firing cycle), 22,000 V peak-to-peak (nonsinusoidal)
Frequency50/60 Hz
Energy Discharge200 millijoules per spark
Discharge Time0.3 milliseconds per spark
Mounting TypesSurface mount
ApplicationsIgnites gas pilots on commercial or industrial gas burners; not recommended for oil ignition
Firing Rate60 sparks per second
Spark GapUp to 1/4 in (6 mm)
Temperature Range-40 to +125°F
Approximate, Dimensions6 3/4 in. high x 4 1/4 in. wide x 3 in. deep (171.5 mm high x 108 mm wide x 76 mm deep)
Weight lb. (kg)3 lb (1.4 kg)
Approvals, Underwriters Laboratories Inc.Component Recognized Approvals, CSA: Certified: File No. LR95329
Operating Humidity Range (% RH)95% RH

Values retain manufacturer model qualifications. Review Honeywell specifications ↗

Part Number

Published part numbers

6 parts

Part NumberDescriptionEnquiry
32004766-001/UIgnition cable assyRequest quotation
32004766-002/U3.05M IGNITION CABLE FOR Q624Request quotation
32004766-003/UIgnition/flame rod cable priced per footRequest quotation
Q624A1014/BSPARK IGNITERRequest quotation
Q624A1014/UIGNITION TRANSFORMERRequest quotation
S720A1040/UIGNITION SPARK GENERATOR S720Request quotation
Manufacturer sources

https://process.honeywell.com/us/en/products/thermal-solutions/burner-management-systems/ignition-components/q624-ignition-transformer

Last source check: 2026-11-02

Q624 Product Image · Manufacturer ownership retained; republication licence not independently confirmed

ABID Automation LTD maintains this independent product reference. Honeywell owns its product names and trademarks. Current manufacturer documentation governs specification, availability and certification.

Your next project. A clear starting point.

Tell us about your facility and what you need to achieve.