Small Volume Provers (SVP) and Controllers
Small Volume Prover Controller
The Small Volume Prover controller supervises proving cycles and provides live status, alarms and diagnostics.
The Small Volume Prover controller supervises proving cycles and provides live status, alarms and diagnostics. Its local display shows piston and motor information alongside cycle-related data, while a handheld access device supports operation. Honeywell describes it as a replacement path for older control modules and a controller for new provers, including control of water-draw operations when needed.
Features & Benefits
- Functions
- Proving-cycle control, alarms and diagnostics
- Display
- 3.5-inch six-line display
- Improves visibility of proving operation
Applications
- Small Volume Prover control and water draw
Detailed capabilities
Product and configuration
The Small Volume Prover controller supervises proving cycles and provides live status, alarms and diagnostics. Its local display shows piston and motor information alongside cycle-related data, while a handheld access device supports operation. Honeywell describes it as a replacement path for older control modules and a controller for new provers, including control of water-draw operations when needed.
- Functions: Proving-cycle control, alarms and diagnostics
- Display: 3.5-inch six-line display
Operation and integration
A local 3.5-inch six-line display shows piston position, motor and error status, cycle data and sweep time. The handheld Local Access Device provides menu access to settings and system information. A cycle counter can trigger a user-set maintenance alarm. Sweep time and repeatability information describe piston travel between optical switches, supporting proving-pulse calculations and run comparison.
Application and selection
The controller supports live proving supervision, diagnostics, data handling and water draw when required. The page describes an intrinsically safe arrangement with ATEX/CSA approvals for the relevant installation. Selecting it as an upgrade requires the applicable prover and control-module compatibility, not merely a matching display size.
Software & Interface
- Display
- 3.5 in Full Color LCD, 6-line Multifunction Display; Real-Time Monitoring and Control
Environmental Conditions
- Ambient Temperature Range
- -40 to +40 deg C (-40 to 104 deg F); -20 to +60 deg C (-4 to 140 deg F) (model dependent)
- Relative Humidity
- 5 to 95% RH (Non-Condensing)
- Pressure Drop
- ≤ 10 psig (using water)
Processing & Performance Metrics
- Flow Rate Rangeability
- >1200:1
Overview
- Handheld Controller
- Local Access Device (LAD), Menu-Driven Display, Programming, Alarms, Water Draw, Cycle Counter
Standards & Certifications
- Ingress Protection
- IP56
- Approvals
- ATEX II 2 (1) G Ex d [ia Ga] IIB T4 (T3) Gb; CSA/us Class I, Div.1, Group C T3B; CSA/us Class I, Div.1, Group D T2C; IECEx Ex d [ia] IIB T4 Gb
Measurement & Sensor Related (Measurement Capabilities)
- Repeatability
- ≤ 0.02% (API MPMS Chapter 4.2)
Electrical Specifications
- Power Supply
- 100 to 240 VAC (Single Phase), 24 VDC (70 W Recommended)
Others
- Fluid Temperature Range
- -40 to +80 deg C; -40 to 176 deg F
| Parameter | Published value / configuration |
|---|---|
| Display | 3.5 in Full Color LCD, 6-line Multifunction Display; Real-Time Monitoring and Control |
| Ambient Temperature Range | -40 to +40 deg C (-40 to 104 deg F); -20 to +60 deg C (-4 to 140 deg F) (model dependent) |
| Relative Humidity | 5 to 95% RH (Non-Condensing) |
| Pressure Drop | ≤ 10 psig (using water) |
| Flow Rate Rangeability | >1200:1 |
| Handheld Controller | Local Access Device (LAD), Menu-Driven Display, Programming, Alarms, Water Draw, Cycle Counter |
| Ingress Protection | IP56 |
| Approvals | ATEX II 2 (1) G Ex d [ia Ga] IIB T4 (T3) Gb; CSA/us Class I, Div.1, Group C T3B; CSA/us Class I, Div.1, Group D T2C; IECEx Ex d [ia] IIB T4 Gb |
| Repeatability | ≤ 0.02% (API MPMS Chapter 4.2) |
| Power Supply | 100 to 240 VAC (Single Phase), 24 VDC (70 W Recommended) |
| Fluid Temperature Range | -40 to +80 deg C; -40 to 176 deg F |
Values retain manufacturer model qualifications. Review Honeywell specifications ↗
Resources
Resources linked from the manufacturer’s page. Confirm the document revision and applicable model before installation or ordering.
Honeywell resource listing ↗Part Number
Published part numbers
10 parts
| Part Number | Description | Enquiry |
|---|---|---|
| 13101837 | 401D COMPLETE ASSEMBLY | Request quotation |
| 323-0050601 | CAN SVP ASSEMBLY | Request quotation |
| 323-0050603 | CAN-PSF-24VDC ASSEMBLY | Request quotation |
| 323-10330-SVP | HMI Assembly for SVP | Request quotation |
| 323-10331-SVP | CAN OPTION ASSEMBLY FOR SVP | Request quotation |
| 44100417 | KIT SVP CTLR COMPLETE CSA, 24VDC | Request quotation |
| 44100418 | KIT SVP CTLR COMPLETE CSA, 110VAC+24VDC | Request quotation |
| 44100419 | KIT SVP CTLR COMPLETE CSA, 230VAC+24VDC | Request quotation |
| 44100420 | KIT SVP CTLR COMPLETE CSA, 3PHZ+24VDC | Request quotation |
| 44100421 | KIT SVP CTLR COMPLETE CSA, 110VAC+1PHZ | Request quotation |
Manufacturer sources
Last source check: 2026-11-02
Small Volume Prover Controller Image · Manufacturer ownership retained; republication licence not independently confirmed
ABID Automation LTD maintains this independent product reference. Honeywell owns its product names and trademarks. Current manufacturer documentation governs specification, availability and certification.
Your next project. A clear starting point.
Tell us about your facility and what you need to achieve.