Fire & Life Safety · Building Systems · Industrial Automation [email protected] +880 1347 561 256
Honeywell Process Measurement & Control

Small Volume Provers (SVP) and Controllers

Small Volume Prover Controller

The Small Volume Prover controller supervises proving cycles and provides live status, alarms and diagnostics.

The Small Volume Prover controller supervises proving cycles and provides live status, alarms and diagnostics. Its local display shows piston and motor information alongside cycle-related data, while a handheld access device supports operation. Honeywell describes it as a replacement path for older control modules and a controller for new provers, including control of water-draw operations when needed.

Features & Benefits

Functions
Proving-cycle control, alarms and diagnostics
Display
3.5-inch six-line display
  • Improves visibility of proving operation

Applications

  • Small Volume Prover control and water draw

Detailed capabilities

Product and configuration

The Small Volume Prover controller supervises proving cycles and provides live status, alarms and diagnostics. Its local display shows piston and motor information alongside cycle-related data, while a handheld access device supports operation. Honeywell describes it as a replacement path for older control modules and a controller for new provers, including control of water-draw operations when needed.

  • Functions: Proving-cycle control, alarms and diagnostics
  • Display: 3.5-inch six-line display

Manufacturer reference ↗

Operation and integration

A local 3.5-inch six-line display shows piston position, motor and error status, cycle data and sweep time. The handheld Local Access Device provides menu access to settings and system information. A cycle counter can trigger a user-set maintenance alarm. Sweep time and repeatability information describe piston travel between optical switches, supporting proving-pulse calculations and run comparison.

Manufacturer reference ↗

Application and selection

The controller supports live proving supervision, diagnostics, data handling and water draw when required. The page describes an intrinsically safe arrangement with ATEX/CSA approvals for the relevant installation. Selecting it as an upgrade requires the applicable prover and control-module compatibility, not merely a matching display size.

Manufacturer reference ↗

Case studies & further resources

Manufacturer Document

Honeywell Enraf SVP Controller Operation Manual

View resource ↗
Manufacturer Document

IECEx Certificate of Conformity SVP Controller (DEKRA)

View resource ↗

Specifications

Software & Interface

Display
3.5 in Full Color LCD, 6-line Multifunction Display; Real-Time Monitoring and Control

Environmental Conditions

Ambient Temperature Range
-40 to +40 deg C (-40 to 104 deg F); -20 to +60 deg C (-4 to 140 deg F) (model dependent)
Relative Humidity
5 to 95% RH (Non-Condensing)
Pressure Drop
≤ 10 psig (using water)

Processing & Performance Metrics

Flow Rate Rangeability
>1200:1

Overview

Handheld Controller
Local Access Device (LAD), Menu-Driven Display, Programming, Alarms, Water Draw, Cycle Counter

Standards & Certifications

Ingress Protection
IP56
Approvals
ATEX II 2 (1) G Ex d [ia Ga] IIB T4 (T3) Gb; CSA/us Class I, Div.1, Group C T3B; CSA/us Class I, Div.1, Group D T2C; IECEx Ex d [ia] IIB T4 Gb

Measurement & Sensor Related (Measurement Capabilities)

Repeatability
≤ 0.02% (API MPMS Chapter 4.2)

Electrical Specifications

Power Supply
100 to 240 VAC (Single Phase), 24 VDC (70 W Recommended)

Others

Fluid Temperature Range
-40 to +80 deg C; -40 to 176 deg F
Small Volume Prover Controller — manufacturer page values
ParameterPublished value / configuration
Display3.5 in Full Color LCD, 6-line Multifunction Display; Real-Time Monitoring and Control
Ambient Temperature Range-40 to +40 deg C (-40 to 104 deg F); -20 to +60 deg C (-4 to 140 deg F) (model dependent)
Relative Humidity5 to 95% RH (Non-Condensing)
Pressure Drop≤ 10 psig (using water)
Flow Rate Rangeability>1200:1
Handheld ControllerLocal Access Device (LAD), Menu-Driven Display, Programming, Alarms, Water Draw, Cycle Counter
Ingress ProtectionIP56
ApprovalsATEX II 2 (1) G Ex d [ia Ga] IIB T4 (T3) Gb; CSA/us Class I, Div.1, Group C T3B; CSA/us Class I, Div.1, Group D T2C; IECEx Ex d [ia] IIB T4 Gb
Repeatability≤ 0.02% (API MPMS Chapter 4.2)
Power Supply100 to 240 VAC (Single Phase), 24 VDC (70 W Recommended)
Fluid Temperature Range-40 to +80 deg C; -40 to 176 deg F

Values retain manufacturer model qualifications. Review Honeywell specifications ↗

Resources

Filter documents by type

Resources linked from the manufacturer’s page. Confirm the document revision and applicable model before installation or ordering.

Honeywell resource listing ↗

Part Number

Published part numbers

10 parts

Part NumberDescriptionEnquiry
13101837401D COMPLETE ASSEMBLYRequest quotation
323-0050601CAN SVP ASSEMBLYRequest quotation
323-0050603CAN-PSF-24VDC ASSEMBLYRequest quotation
323-10330-SVPHMI Assembly for SVPRequest quotation
323-10331-SVPCAN OPTION ASSEMBLY FOR SVPRequest quotation
44100417KIT SVP CTLR COMPLETE CSA, 24VDCRequest quotation
44100418KIT SVP CTLR COMPLETE CSA, 110VAC+24VDCRequest quotation
44100419KIT SVP CTLR COMPLETE CSA, 230VAC+24VDCRequest quotation
44100420KIT SVP CTLR COMPLETE CSA, 3PHZ+24VDCRequest quotation
44100421KIT SVP CTLR COMPLETE CSA, 110VAC+1PHZRequest quotation
Manufacturer sources

https://process.honeywell.com/us/en/products/terminals/provers/small-volume-provers-svp-and-controllers/small-volume-prover-controller

Last source check: 2026-11-02

Small Volume Prover Controller Image · Manufacturer ownership retained; republication licence not independently confirmed

ABID Automation LTD maintains this independent product reference. Honeywell owns its product names and trademarks. Current manufacturer documentation governs specification, availability and certification.

Your next project. A clear starting point.

Tell us about your facility and what you need to achieve.

CallSend enquiry